Catalog item
Request a quoteVACUUM PUMP UNIT,ROTARY
4310FSC
00NCB code
426-2047Item number
NIIN 00-426-2047
- DEMIL code
- A
Identification
- Item name code
- 29904
- PINC
- 0029904
- Criticality code
- S
- II
- N
- DEMIL code
- A
- DEMIL integrity code
- 7
- NIIN assigned
- 28-APR-71
- Precious metals indicator
- U
- Hazardous material indicator
- N
- Schedule B export code
- 8414100000
- IUID indicator
- Y
Part numbers
Characteristics
| BRAKE HORSEPOWER REQUIRED | 3.100 |
|---|---|
| GAS FOR WHICH DESIGNED | AIR |
| COOLING MEDIUM | WATER |
| PUMPING ELEMENT TYPE | LOBE |
| INTAKE CONNECTION TYPE | FLANGED |
| AIR DISPLACEMENT RATE | CUBIC FEET PER MINUTE IN FREE AIR 35.0 |
| SYSTEM DESIGN | CORROSIVE |
| PRIME MOVER TYPE | ELECTRIC MOTOR |
| OVERALL HEIGHT | INCHES NOMINAL 12.500 |
| OVERALL WIDTH | INCHES NOMINAL 15.310 |
| CURRENT RATING IN AMPS | 6.5 |
| CRITICALITY CODE JUSTIFICATION | ZZZY |
| OPERATING SPEED AT RATED CAPACITY IN RPM | 1750.0 |
| VOLTAGE IN VOLTS | 440.0 |
| PHASE | THREE |
| FREQUENCY IN HERTZ | 60.0 |
| REFERENCE NUMBER DIFFERENTIATING CHARACTERISTICS | TRIDENT PLANNED EQUIPMENT REPLACEMENT (TRIPER) AND ADVANCED EQUIPMENT REPAIR PROGRAM (AERP) PROCEDURES IAW NAVSUP WSS INST 4420.170 OPERATING PROCEDURE 3. INCLUDES BOTH L1/SS/Q3/Q5/SOC AND NON-L1/SS/Q3/Q5/SOC TRIPER/AERP COMPONENTS. TRIPER/AERP EQUIPMENT HAVE SPECIAL REQUIREMENTS BUT NO SPECIFIC MATERIAL CONTROL |
| INTAKE CONNECTION QUANTITY | 1 |
| MOUNTING TYPE | BASE |
| STAGE QUANTITY | 1 |
| CURRENT TYPE | AC |
| OVERALL LENGTH | INCHES NOMINAL 30.000 |
| DRIVE CONNECTION TYPE | CLOSE COUPLED |
| DISCHARGE CONNECTION QUANTITY | 1 |
| DISCHARGE CONNECTION TYPE | FLANGED |
Freight
- ACTY CD
- HD
- NMFC
- 128000
- NMFC sub
- X
- Uniform freight class
- 64870
- Less than truckload
- M
- Less than carload
- M
- Water commodity code
- 594
- Type of cargo code
- Z
- Special handling code
- 9
- Air dimension code
- A
- Air commodity code
- VZ
- NMF description
- PUMPS PWR NOI/WORKING HEADS/PARTS
Packaging
Unit and preservation
- PICA SICA
- P
- PKG cat
- ZZZW
- Unpackaged weight
- 0.0000
- Unpackaged width
- 0.000
- Unpackaged length
- 0.000
- Unpackaged height
- 0.000
- TOS
- B
- Intermediate container qty
- 000No intermediate container quantity specified (000)
- Method of preservation
- ZZSpecial requirements apply that are not represented by the code symbols; details are provided with the acquisition...
- Clng drying
- 1Any suitable process that is not injurious to the item.
- Pres mat
- 89Preserve with normal operating lubricant
- Wrap mat
- ZZSpecial requirements – see specific instructions or drawings provided
- Cush dun
- ZZSpecial requirements.
- THK
- ZSpecial requirements – See specific instructions or drawings provided
- Unit cont
- FCASTM D6880, Class 2, heavy duty wood box.
- PKG data source
- A
Unit pack
- PICA SICA
- P
- SPC MKG
- 24Open for inspection or use only
- Inter cont
- 00No requirement.
- UCL
- AUnit container provides level A packing protection.
- Lvl A
- FPacking is not required: the unit container shall also serve as the shipping container.
- Lvl b
- FPacking is not required: the unit container shall also serve as the shipping container.
- Lvl c
- FPacking is not required; the unit container shall also serve as the shipping container.
- Unit pack weight
- 0.0000
- UP SZ MAXB
- 28.50000
- UP SZ MAXL
- 31.40000
- UP SZ MAXH
- 29.60000
- Unit pack cube
- 15.3290
- OPI
- APackaging is in accordance with a procedural specification or an SPI.
- Supplemental instructions
- PACKAGE PER MIL-P-16789
Packaging instructions
- PICA SICA
- P
- SPI date
- 00000
Related items
Standardization
- Item standardization code
- C
- Orig stdzn dec
- AX
- Dt stdzn dec
- 21-JUN-1983
- NIIN status code
- 0
Request a quote
Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.