Catalog item
Request a quoteVACUUM PUMP UNIT,ROTARY
4310FSC
00NCB code
898-9959Item number
NIIN 00-898-9959
- Unit price
- $21,142.00
- Unit of issue
- EA
- Source of supply
- FLZ
- DEMIL code
- A
Identification
- Item name code
- 29904
- PINC
- 0029904
- Criticality code
- X
- II
- 0
- DEMIL code
- A
- DEMIL integrity code
- 1
- NIIN assigned
- 01-JAN-63
- Precious metals indicator
- A
- ADP equipment code
- 0
- Hazardous material indicator
- N
- Schedule B export code
- 8414100000
- IUID indicator
- Y
Management
| Effective date | Major organizational entity | Acquisition advice code | Source of supply | Unit of issue | Unit of measure quantity | Unit price | Quantity per unit pack | Controlled inventory item code | Shelf-life code | Recoverability code | Management control | Net price | USC |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 01-FEB-2020 | DF | W | FLZ | EA | 0.0000 | $21,142.00 | 1 | U | 0 | U | --M---N | $0.00 | L |
| 01-FEB-2026 | DN | W | NRP | EA | 0.0000 | $29,690.00 | 1 | U | 0 | H | 7EHBBL9 | $2,500.00 | N |
Part numbers
| Part number | CAGE | CAGE status | RNCC | RNVC | Document availability code | RNAAC | RNFC | RNSC |
|---|---|---|---|---|---|---|---|---|
| PMU4E | 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M | A | 5 | 9 | 4 | XX | 3 | B |
| MIL-V-27314 CANCELED | 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M | A | 4 | 1 | 4 | SB | 1 | C |
| MME4310-597 | 98752 WARNER ROBINS AIR LOGISTICS CENTER | A | 5 | 1 | 5 | SB | 1 | A |
| PD05WRGBZREF25 | 98752 WARNER ROBINS AIR LOGISTICS CENTER | A | 3 | 2 | 3 | ZZ |
Characteristics
| COOLING MEDIUM | AIR |
|---|---|
| MOUNTING TYPE | WHEEL |
| CURRENT TYPE | AC |
| DRIVE CONNECTION TYPE | SINGLE STRAND V-BELT |
| OVERALL WIDTH | INCHES NOMINAL 50.000 |
| INTAKE CONNECTION QUANTITY | 1 |
| INTAKE CONNECTION TYPE | UNTHREADED EXTERNAL |
| OVERALL LENGTH | INCHES NOMINAL 50.000 |
| OVERALL HEIGHT | INCHES NOMINAL 36.000 |
| STAGE QUANTITY | 1 |
| GAS FOR WHICH DESIGNED | OXYGEN |
| BRAKE HORSEPOWER REQUIRED | 1.500 |
| DISCHARGE CONNECTION QUANTITY | 1 |
| DISCHARGE CONNECTION TYPE | UNTHREADED EXTERNAL |
| SYSTEM DESIGN | CORROSIVE |
| PRIME MOVER TYPE | ELECTRIC MOTOR |
| CURRENT RATING IN AMPS | 4.8 AND 2.4 |
| VOLTAGE IN VOLTS | 220.0 AND 440.0 |
| PHASE | THREE |
| SPECIAL FEATURES | EXPLOSION PROOF MOTOR |
| FREQUENCY IN HERTZ | 60.0 |
| FUNCTIONAL DESCRIPTION | THE PMU-4E,POWER DRIVEN ROTARY VACUUM PUMP IS AN INDEPENDENT,SELF-CONTAINED UNIT; IT CONSISTS OF A ROTARY VACUUM PUMP DRIVEN BY AN EXPLOSION PROOF ELECTRIC MOTOR AND EXPLOSION PROOF CONTROL EQUIPMENT MOUNTED ON A FOUR CASTERED MOBILE BASE WITH ATTACHED HANDLE FOR MANUALLY MOVING THE EQUIPMENT; A SIX FOOT LENGTH OF FLEXIBLE SERVICING HOSE WITH STORAGE TANK ADAPTER IS SUPPLIED FOR USE IN CONNECTING THE VACUUM PUMP TO THE VACUUM PUMP TO THE STORAGE TANK BEING EVACUATED; THE VACUUM PUMP IS DESIGNED PRIMARILY FOR EVACUATING THE VACUUM TIGHT ANNULAR INSULATING SPACE OF LIQUID OXYGEN OR NITROGEN STORAGE TANK TO AN ABSOLUTE PRESSURE OF FIVE MICRONS OR LESS; THE UNIT IS CONSTRUCTED FOR THAT REPAIRS MAY BE ACCOMPLISHED BY OPERATING PERSONNEL |
| ENTRY DATE | 85-08-15 |
| REFERENCE DATA AND LITERATURE | AF TO. 35M12-2-12-1 |
| NONDEFINITIVE SPEC/STD DATA | TYPE -U TO 4E |
| VACUUM RATING | MILLITORR 1.0 |
| PUMP QUANTITY | 1 |
| PUMPING ELEMENT TYPE | SLIDING VANE AND ROTARY PISTON |
| INTAKE CONNECTION OUTSIDE DIAMETER | INCHES NOMINAL 1.000 |
| DISCHARGE CONNECTION OUTSIDE DIAMETER | INCHES NOMINAL 1.000 |
| AIR DISPLACEMENT RATE | CUBIC FEET PER MINUTE IN FREE AIR 14.0 |
MOE rules
| MOE rule | MOE CD | AMC | AMSC | NIMSC | Date assigned | IMC | IMCA | PICA | PICA LOA | SICA | SICA LOA | Auth collab | Supp collab | DSOR |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ZH01 | ZH | 01-APR-91 | ZH | 81 | ZH | |||||||||
| ZU01 | ZU | 01-APR-91 | ZU | 81 | ZU | |||||||||
| ZW01 | ZW | 01-NOV-05 | ZW | 81 | ZW | |||||||||
| FGG4 | DF | 2 | G | F | 01-APR-91 | D | TG | TG | 22 | TU | FR | |||
| NSGS | DN | 2 | G | 1 | 01-AUG-02 | D | TG | 22 | HD | 8D | HD TU | GG | 00 |
Management phrases
| Major organizational entity | USC | Phrase code | Phrase | Quantity per assembly | Technical document |
|---|---|---|---|---|---|
| DF | L | R | REFER TO P003238866 | 0 | P003238866 |
| DF | L | R | REFER TO P008064374 | 0 | P008064374 |
| DF | L | R | REFER TO P010164191 | 0 | P010164191 |
| DF | L | R | REFER TO P000664682 | 0 | P000664682 |
| DF | L | R | REFER TO P015428391 | 0 | P015428391 |
| DF | L | R | REFER TO P012330202 | 0 | P012330202 |
| DF | L | R | REFER TO P010612896 | 0 | P010612896 |
Service data
Navy
- COG
- 7E
- SMIC
- HB
- IRRC
- BL
- SMCC
- 9
Air Force
- Budget
- M
- PVC
- N
- ERRC
- U
Freight
- ACTY CD
- XX
- NMFC
- 128000
- NMFC sub
- X
- Uniform freight class
- 64870
- Less than truckload
- M
- Less than carload
- M
- Water commodity code
- 594
- Type of cargo code
- Z
- Special handling code
- Z
- Air dimension code
- A
- Air commodity code
- VZ
- NMF description
- PUMPS PWR NOI/WORKING HEADS/PARTS
Packaging
Unit and preservation
| PICA SICA | PKG cat | Unpackaged weight | Unpackaged width | Unpackaged length | Unpackaged height | Unit of issue | TOS | Intermediate container qty | Method of preservation | Clng drying | Pres mat | Wrap mat | Cush dun | THK | Unit cont | PKG data source |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| P | ZZZZ | 0.0000 | 0.000 | 0.000 | 0.000 | EA | 000 No intermediate container quantity specified (000) | ZZ Special requirements apply that are not represented by the code symbols; details are provided with the acquisition... | 1 Any suitable process that is not injurious to the item. | ZZ Special requirement – See specific instructions or drawings provided | ZZ Special requirements – see specific instructions or drawings provided | ZZ Special requirements. | Z Special requirements – See specific instructions or drawings provided | ZZ Special requirement – See specific instructions or drawings provided. | P | |
| S | ZZZ0 | 0.0000 | 0.000 | 0.000 | 0.000 | EA | B | 000 No intermediate container quantity specified (000) | ZZ Special requirements apply that are not represented by the code symbols; details are provided with the acquisition... | 1 Any suitable process that is not injurious to the item. | 00 No requirement | ZZ Special requirements – see specific instructions or drawings provided | ZZ Special requirements. | Z Special requirements – See specific instructions or drawings provided | ZZ Special requirement – See specific instructions or drawings provided. | A |
Unit pack
| PICA SICA | SPC MKG | Inter cont | UCL | Lvl A | Lvl b | Lvl c | Unit pack weight | UP SZ MAXB | UP SZ MAXL | UP SZ MAXH | Unit pack cube | OPI | Supplemental instructions |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| P | ZZ Special requirements | 00 No requirement. | A Unit container provides level A packing protection. | 0.0000 | 0.00000 | 0.00000 | 0.00000 | 0.0000 | A Packaging is in accordance with a procedural specification or an SPI. | ||||
| S | 00 No special marking | 00 No requirement. | O Unit container is not an acceptable shipping container. | E Packing shall be accomplished to meet the performance test requirements of ASTM D4169, Distribution Cycle 18,... | Q Packing shall be accomplished in accordance with table C-II for the packing level specified. | Q | 0.0000 | 0.00000 | 0.00000 | 0.00000 | 0.0000 | A Packaging is in accordance with a procedural specification or an SPI. | ZZ = PACKAGE PER MIL-P-16789 REQUIREMENTS |
Packaging instructions
| PICA SICA | SPI no | SPI rev | SPI date |
|---|---|---|---|
| P | F010612896 | D | 96116 |
| S | 00000 |
Related items
Standardization
- Item standardization code
- 2
- Orig stdzn dec
- AX
- Dt stdzn dec
- 15-DEC-1974
- NIIN status code
- 0
Request a quote