Catalog item
Request a quotePUMP UNIT,CENTRIFUGAL
4320FSC
00NCB code
059-2392Item number
NIIN 00-059-2392
- Unit price
- $26,551.00
- Unit of issue
- EA
- Source of supply
- NRP
- DEMIL code
- A
Identification
- Item name code
- 17988
- PINC
- 0017988
- Criticality code
- X
- II
- N
- DEMIL code
- A
- DEMIL integrity code
- 1
- NIIN assigned
- 01-JAN-61
- Precious metals indicator
- A
- ADP equipment code
- 0
- Hazardous material indicator
- N
- Schedule B export code
- 8413919520
- IUID indicator
- Y
Management
- Effective date
- 01-OCT-2024
- Major organizational entity
- DN
- Acquisition advice code
- J
- Source of supply
- NRP
- Unit of issue
- EA
- Unit of measure quantity
- 0.0000
- Unit price
- $26,551.00
- Quantity per unit pack
- 0
- Controlled inventory item code
- U
- Shelf-life code
- 0
- Recoverability code
- H
- Management control
- 7H--009
- Net price
- $7,949.00
- USC
- L
Part numbers
| Part number | CAGE | CAGE status | RNCC | RNVC | Document availability code | RNAAC | RNFC | RNSC | SADC |
|---|---|---|---|---|---|---|---|---|---|
| CVA42S8302-1122614 | 80064 NAVAL SHIP SYSTEMS COMMAND | A | 5 | 1 | 5 | XX | 3 | D | |
| RW110318 | 93232 CURTISS-WRIGHT ELECTRO-MECHANICAL CORPORATION DBA CURTISS WRIGHT ENGINEERED PUMP DIVISION USE CAGE CODE 0UBG9 FOR CATALOGING | R | 3 | 9 | 5 | XX | 3 | D | |
| RW110318 | 0UBG9 CURTISS-WRIGHT ELECTRO-MECHANICAL CORPORATION DIV EPD | A | C | 1 | 5 | ZZ | 3 | D | 9F |
Characteristics
| TOTAL HEAD | FEET 229.000 |
|---|---|
| OPERATING SPEED AT RATED CAPACITY | REVOLUTIONS PER MINUTE 3500.0 |
| CENTRIFUGAL PUMP DESIGN | RADIAL FLOW |
| CENTRIFUGAL PUMP IMPELLER QUANTITY | 1 |
| CENTRIFUGAL PUMP IMPELLER SUCTION TYPE | SINGLE |
| MAXIMUM DISCHARGE FLOW RATE | GALLONS PER MINUTE 650.0 |
| PRIME MOVER QUANTITY | 1 |
| STAGE QUANTITY | 1 |
| INTAKE CONNECTION QUANTITY | 1 |
| INTAKE CONNECTION TYPE | ROUND FLANGE |
| DISCHARGE CONNECTION QUANTITY | 1 |
| DISCHARGE CONNECTION TYPE | ROUND FLANGE |
| CURRENT TYPE | AC |
| COOLING MEDIUM | PRIME MOVER AIR |
| ENVIRONMENTAL PROTECTION | WATERTIGHT |
| PUMP QUANTITY | 1 |
| FREQUENCY IN HERTZ | 60.0 |
| MEDIA FOR WHICH DESIGNED | LOCATION NOT OTHERWISE SPECIFIED WATER, FRESH |
| REFERENCE NUMBER DIFFERENTIATING CHARACTERISTICS | AS DIFFERENTIATED WITHOUT REPAIR PARTS |
| VOLTAGE IN VOLTS | 440.0 |
| PHASE | THREE |
| COOLING METHOD | BLOWER COOLED |
| INCLOSURE TYPE | FULLY INCLOSED |
| CURRENT RATING IN AMPS | 65.0 |
| PRIME MOVER TYPE | ELECTRIC MOTOR |
MOE rules
- MOE rule
- N2H4
- MOE CD
- DN
- AMC
- 3
- AMSC
- R
- NIMSC
- P
- Date assigned
- 01-MAR-95
- IMC
- E
- PICA
- HD
- PICA LOA
- 22
- Auth collab
- HD
- Supp collab
- GH
- DSOR
- CN
- Fmr MOE rl
- N9CD
Service data
Navy
- COG
- 7H
- IRRC
- 00
- SMCC
- 9
Freight
- ACTY CD
- XX
- NMFC
- 128000
- NMFC sub
- X
- Uniform freight class
- 64870
- Less than truckload
- M
- Less than carload
- M
- Water commodity code
- 594
- Type of cargo code
- Z
- Special handling code
- 9
- Air dimension code
- A
- Air commodity code
- VZ
- NMF description
- PUMPS PWR NOI/WORKING HEADS/PARTS
Packaging
Unit and preservation
- PICA SICA
- P
- PKG cat
- ZZZZ
- Unpackaged weight
- 0.0000
- Unpackaged width
- 0.000
- Unpackaged length
- 0.000
- Unpackaged height
- 0.000
- Unit of issue
- EA
- TOS
- B
- Intermediate container qty
- 000No intermediate container quantity specified (000)
- Method of preservation
- ZZSpecial requirements apply that are not represented by the code symbols; details are provided with the acquisition...
- Clng drying
- ZSpecial requirements - See specific instructions or drawings provided.
- Pres mat
- ZZSpecial requirement – See specific instructions or drawings provided
- Wrap mat
- ZZSpecial requirements – see specific instructions or drawings provided
- Cush dun
- ZZSpecial requirements.
- THK
- ZSpecial requirements – See specific instructions or drawings provided
- Unit cont
- ZZSpecial requirement – See specific instructions or drawings provided.
- PKG data source
- A
Unit pack
- PICA SICA
- P
- SPC MKG
- 00No special marking
- Inter cont
- ZZSpecial requirement – See specific instructions or drawings provided.
- UCL
- OUnit container is not an acceptable shipping container.
- Lvl A
- EPacking shall be accomplished to meet the performance test requirements of ASTM D4169, Distribution Cycle 18,...
- Lvl b
- QPacking shall be accomplished in accordance with table C-II for the packing level specified.
- Lvl c
- Q
- Unit pack weight
- 0.0000
- UP SZ MAXB
- 0.00000
- UP SZ MAXL
- 0.00000
- UP SZ MAXH
- 0.00000
- Unit pack cube
- 0.0000
- OPI
- MAll packaging data is mandatory for compliance and no substitutions are permitted.
- Supplemental instructions
- ZZ = PACKAGING UPDATE REQUIRED
Packaging instructions
- PICA SICA
- P
- SPI date
- 00000
Related items
Standardization
- Item standardization code
- 2
- Orig stdzn dec
- AX
- Dt stdzn dec
- 11-MAR-1972
- NIIN status code
- 0
Request a quote