Catalog item

PUMP UNIT,ROTARY

4320FSC
00NCB code
482-6372Item number
NIIN 00-482-6372
Request a quote
DEMIL code
A

Identification

Item name code
18181
PINC
0018181
Criticality code
X
II
M
DEMIL code
A
NIIN assigned
01-FEB-71
Precious metals indicator
A
ADP equipment code
0
Hazardous material indicator
N
Schedule B export code
8413600090
IUID indicator
Y

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
SG385359180
CIRCOR PUMPS NORTH AMERICA LLC
A321HA
SG385316712
SIEMENS ENERGY, INC.
A591HA3B

Characteristics

DISCHARGE CONNECTION QUANTITY1
PUMP QUANTITY1
MEDIA FOR WHICH DESIGNEDLOCATION NOT OTHERWISE SPECIFIED FUEL/OIL, HYDROCARBON
PRIME MOVER TYPESTEAM TURBINE
DISCHARGE CONNECTION TYPEROUND FLANGE
INTAKE CONNECTION QUANTITY1
INTAKE CONNECTION TYPEROUND FLANGE
EXHAUST PRESSUREPOUNDS PER SQUARE INCH GAGE 15.0
PRIME MOVER QUANTITY1
MOUNTING TYPEBASE
MAXIMUM DISCHARGE FLOW RATEGALLONS PER MINUTE 700.0
DISCHARGE PRESSUREPOUNDS PER SQUARE INCH GAUGE (PSIG) 150.0
OPERATING SPEED AT RATED CAPACITYREVOLUTIONS PER MINUTE 1150.0
ROTARY PUMP DESIGNSCREW
OPERATING PRESSUREPOWER DRIVE POUNDS PER SQUARE INCH GAUGE (PSIG) NOMINAL 575.0

Freight

ACTY CD
HD
NMFC
128000
NMFC sub
X
Uniform freight class
64870
Less than truckload
M
Less than carload
M
Water commodity code
594
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
VZ
NMF description
PUMPS PWR NOI/WORKING HEADS/PARTS

Packaging

Unit and preservation

PICA SICA
P
PKG cat
ZZZZ
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
Y
Intermediate container qty
000
No intermediate container quantity specified (000)
Method of preservation
ZZ
Special requirements apply that are not represented by the code symbols; details are provided with the acquisition...
Clng drying
Z
Special requirements - See specific instructions or drawings provided.
Pres mat
ZZ
Special requirement – See specific instructions or drawings provided
Wrap mat
ZZ
Special requirements – see specific instructions or drawings provided
Cush dun
ZZ
Special requirements.
THK
Z
Special requirements – See specific instructions or drawings provided
Unit cont
ZZ
Special requirement – See specific instructions or drawings provided.
PKG data source
A

Unit pack

PICA SICA
P
SPC MKG
99
Inter cont
00
No requirement.
UCL
O
Unit container is not an acceptable shipping container.
Lvl A
E
Packing shall be accomplished to meet the performance test requirements of ASTM D4169, Distribution Cycle 18,...
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Lvl c
Q
Unit pack weight
0.0000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0000
OPI
A
Packaging is in accordance with a procedural specification or an SPI.
Supplemental instructions
ZZ = MIL-P-16789

Packaging instructions

PICA SICA
P
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
C
Orig stdzn dec
AX
Dt stdzn dec
01-DEC-1974
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.