Catalog item

BOILER,STEAM,HIGH PRESSURE

4410FSC
01NCB code
500-9596Item number
NIIN 01-500-9596
Request a quote
Unit price
$4,607.14
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
03292
PINC
0003292
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
18-SEP-02
Precious metals indicator
A
ADP equipment code
0
Hazardous material indicator
N
FedMall
Y

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DNJSMSEA0.0000$4,607.141U0D3B-----$0.00N
01-OCT-2026DSJSMSEA0.0000$4,607.141U0F-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAAC
9230-D103 ITEM T-260756
CEPEDA ASSOCIATES, INC. DBA CEPEDA ASSOCIATES INC
A52DZZ
9230-B100 ITEM T-260756
CEPEDA ASSOCIATES, INC. DBA CEPEDA ASSOCIATES INC
A52DZZ
9230-D21360756
CEPEDA ASSOCIATES, INC. DBA CEPEDA ASSOCIATES INC
A32DZZ
9230-D200 ITEM T-260756
CEPEDA ASSOCIATES, INC. DBA CEPEDA ASSOCIATES INC
A52DZZ

Characteristics

END ITEM IDENTIFICATIONCO2 SCRUBBER; WSD LOS ANGELES CLASS SSN (688)
SPECIAL FEATURESDESIGN PRESSURE 45 PSIG; DESIGN TEMPERATURE 350 DEG. FAHRENHEIT; BOILER-STRIPPER SHALL BE ACID CLEANED INTERNALLY AND EXTERNALLY IN ACCORDANCE WITH FED SPEC QQ-P-35, TYPE 6,7,8; AFTER ACID CLEANING, BOILER-STRIPPER SHALL BE SUBJECTED TO A HYDROSTATIC PRESSURE TEST USING CLEAN FRESH WATER TO 68 PSIG FOR A MINIMUM OF ONE HR WITHOUT ANY LEAKAGE; FILL REFLUX SECTION AND BOILER TO A LEVEL EVEN WITH TOP OF THE RICH MEA INLET WITH 1/2 IN. 304 STAINLESS STEEL RASCHIG RINGS AFTER HYDROSTATIC TEST
PROPRIETARY CHARACTERISTICSPACS

MOE rules

MOE rule
N9BC
MOE CD
DN
AMC
3
AMSC
H
Date assigned
01-MAY-06
IMC
Z
IMCA
HD
PICA
GX
PICA LOA
01
SICA
GH
SICA LOA
5D
Auth collab
GX
Supp collab
JB HD
Fmr MOE rl
N9CD

Service data

Navy

COG
3B

Freight

ACTY CD
AX
NMFC
025770
NMFC sub
X
Uniform freight class
12210
Less than truckload
R
Water commodity code
593
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
VZ
NMF description
BOILER/HEATING/POWER C IRON HEAT EX

Packaging

Unit and preservation

PICA SICA
P
PKG cat
16Z0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
B
Intermediate container qty
000
No intermediate container quantity specified (000)
Method of preservation
AE
Seal or plug all openings and preserve by Method 10.
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
ZZ
Special requirements – see specific instructions or drawings provided
Cush dun
ZZ
Special requirements.
THK
C
3/4 inch thick
Unit cont
FO
Any suitable wood box included in this table may be used (see J.4.9.1).
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
00
No special marking
Inter cont
00
No requirement.
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
0.0000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0000
OPI
O
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used.

Packaging instructions

PICA SICA
P
PKG design ACTY
16236
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
5
Orig stdzn dec
97
Dt stdzn dec
18-SEP-2002
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.