Request a quoteOVEN,THERMAL DRYING,ELECTRIC
4430FSC
01NCB code
289-8984Item number
NIIN 01-289-8984
- Unit price
- $4,200.00
- Unit of issue
- EA
- Source of supply
- FLZ
- DEMIL code
- A
Identification
- Item name code
- 12824
- PINC
- 0012824
- Criticality code
- X
- II
- M
- DEMIL code
- A
- NIIN assigned
- 02-DEC-88
- Precious metals indicator
- U
- ADP equipment code
- 0
- Hazardous material indicator
- N
- Schedule B export code
- 8514100000
- IUID indicator
- Y
Management
- Effective date
- 01-DEC-2019
- Major organizational entity
- DF
- Acquisition advice code
- J
- Source of supply
- FLZ
- Unit of issue
- EA
- Unit of measure quantity
- 0.0000
- Unit price
- $4,200.00
- Quantity per unit pack
- 1
- Controlled inventory item code
- M
- Shelf-life code
- 0
- Recoverability code
- U
- Management control
- --M---E
- Net price
- $0.00
- USC
- L
Part numbers
- Part number
- MCF-300
- CAGE
- 90423THE GRIEVE CORPORATION DBA GRIEVE CORP
- CAGE status
- A
- RNCC
- 3
- RNVC
- 2
- Document availability code
- 2
- RNAAC
- MG
Characteristics
| FURNISHED ITEMS | DOUBLE-WALL CONSTRUCTED CABINET AND INSULATED CABINET |
|---|---|
| OVERALL DEPTH | INCHES NOMINAL 25.000 |
| OVERALL HEIGHT | INCHES NOMINAL 35.000 |
| OVERALL WIDTH | INCHES NOMINAL 32.000 |
| CURRENT TYPE | AC |
| INSIDE WIDTH | INCHES NOMINAL 23.000 |
| MAXIMUM OPERATING TEMP | CELSIUS 300.0 |
| INSIDE DEPTH | INCHES NOMINAL 18.000 |
| INSIDE HEIGHT | INCHES NOMINAL 19.500 |
| TEMP CONTROL METHOD | AUTOMATIC |
| WATTAGE RATING | WATTS 3100.0 |
| CIRCULATION METHOD | FORCED |
| CABINET DOOR QUANTITY | 1 |
| WORK PROTECTION FROM HEAT SOURCE | COMPLETE |
| NORMAL OPERATING TEMP RANGE | CELSIUS 275.0 TO 300.0 |
| FEATURES PROVIDED | ADJUSTABLE OPENING AND TEST SWITCH AND FLOODLIGHT |
| VOLTAGE IN VOLTS | 208.0 |
| PHASE | SINGLE |
| SPECIAL FEATURES | AUTO-RESTART ON MICROPROCESSOR LOCK UP; PROPORTIONAL TEMP CONT; LGE LED TEMP DISPLAY; PLATINUM RTD TEMP SENSOR; TEMP RECORDER O/P JACK; VISUAL & AUDIBLE ALARMS INDI OV TEMP COND; TEMP CAN BE MAINTAINED OR AUTOMATICALLY SHUTOFF AT END OF TIMING CYCLE; 20 MIN RISE TIME FM AMBIENT TO 200 DEG C; 7 MIN RECOVERY TIME AT 150 DEG C; MICROPROCESSOR BASED TIMER SETTABLE IN UNITS OF MIN OR HR UP TO 99.9 HR; CAN DISPLAY ELAPSED TIME OR TIME REMAINING IN TIMING PERIOD; TIMER CAN BE STARTED AUTOMATICALLY WHEN OVEN TEMP REACHES SET PT; AUDIBLE END OF TIME PERIOD ALARM; STNLS STL HEATER ELEMENTS,BLOWER,SHELVES,INTERIOR,PLENUMS; ENAMELED STL EXT; 3 IN. INSUL - ALL SIDES; PLUG STYL DOOR W/1 PC SILICONE GASKET; 4 PERFORATED STLS STL SHELVES - ADJ ON 1.75 IN. CENTERS; SHELF SUPPORTS & PLENUMS REMOVABLE FOR CLEANING; NO INT FLTR; ADJ 2 IN. FITTING FOR INTRODUCING INERT GAS OR FILTERED AIR |
| FREQUENCY IN HERTZ | 60.0 |
| FUNCTIONAL DESCRIPTION | THE BAKING/CURING OVEN SHALL PROV THE CAPABILITY TO REMOVE EITHER SOLVENTS OR MOISTURE FOR SGL-LAYER & MULTI-LAYER PCB OR WIRING BOARDS & VENT TO THE OSD; THE PCB WILL BE FABRICATED PRIMARILY FRM FR-4 GLASS EPOXY,POLYMIDE OR KAPTON MATL; MATL THK CAN VARY FM 0.008 IN. - 0.25 IN; MAX OF 50,16 IN. X 18 IN. PANELS TO BE BAKED; THE BAKING/CURING PROCESS WILL OCCUR PRIOR TO DRILLING,EXPOSURE,PRESS LAMINATION BUT AFTER DEVELOPING |
| SUPPLEMENTARY FEATURES | MEETS CL 100 ROOM RQMT; MAINTAINS MIN. 275 DEG. C PORM 0.5 DEG. |
MOE rules
- MOE rule
- FGG4
- MOE CD
- DF
- AMC
- 0
- AMSC
- 0
- NIMSC
- X
- Date assigned
- 01-APR-91
- IMC
- D
- IMCA
- TG
- PICA
- TG
- PICA LOA
- 22
- Auth collab
- TU
- DSOR
- 99
Service data
Air Force
- Budget
- M
- PVC
- E
- ERRC
- U
Freight
- ACTY CD
- TG
- NMFC
- 062600
- NMFC sub
- B
- Uniform freight class
- 74250
- Less than truckload
- J
- Water commodity code
- 72D
- Type of cargo code
- Z
- Special handling code
- 9
- Air dimension code
- A
- Air commodity code
- VZ
- NMF description
- OVENS INFRA RED RAY HEATING SUB2
Packaging
Unit and preservation
- PICA SICA
- P
- Unpackaged weight
- 0.0000
- Unpackaged width
- 0.000
- Unpackaged length
- 0.000
- Unpackaged height
- 0.000
- Unit of issue
- EA
- Intermediate container qty
- 000No intermediate container quantity specified (000)
- Method of preservation
- ZZSpecial requirements apply that are not represented by the code symbols; details are provided with the acquisition...
- Clng drying
- ZSpecial requirements - See specific instructions or drawings provided.
- Pres mat
- ZZSpecial requirement – See specific instructions or drawings provided
- Wrap mat
- ZZSpecial requirements – see specific instructions or drawings provided
- Cush dun
- ZZSpecial requirements.
- THK
- ZSpecial requirements – See specific instructions or drawings provided
- Unit cont
- ZZSpecial requirement – See specific instructions or drawings provided.
- PKG data source
- P
Unit pack
- PICA SICA
- P
- SPC MKG
- ZZSpecial requirements
- Inter cont
- 00No requirement.
- UCL
- AUnit container provides level A packing protection.
- Unit pack weight
- 0.0000
- UP SZ MAXB
- 0.00000
- UP SZ MAXL
- 0.00000
- UP SZ MAXH
- 0.00000
- Unit pack cube
- 0.0000
- OPI
- APackaging is in accordance with a procedural specification or an SPI.
Packaging instructions
- PICA SICA
- P
- SPI no
- F012662257
- SPI date
- 94012
Related items
Standardization
- Item standardization code
- 5
- Orig stdzn dec
- 97
- Dt stdzn dec
- 02-DEC-1988
- NIIN status code
- 0
Request a quote