Catalog item
Request a quoteHEATER,WATER,ELECTRIC
4520FSC
01NCB code
527-2619Item number
NIIN 01-527-2619
- Unit price
- $12,231.81
- Unit of issue
- EA
- Source of supply
- SMS
- DEMIL code
- A
Identification
- Item name code
- 07180
- PINC
- 0007180
- Criticality code
- X
- II
- 0
- DEMIL code
- A
- DEMIL integrity code
- 1
- NIIN assigned
- 26-JAN-05
- Precious metals indicator
- A
- ADP equipment code
- 0
- Hazardous material indicator
- N
- Schedule B export code
- 8516100040
- FedMall
- Y
Management
| Effective date | Major organizational entity | Acquisition advice code | Source of supply | Unit of issue | Unit of measure quantity | Unit price | Quantity per unit pack | Controlled inventory item code | Shelf-life code | Recoverability code | Management control | Net price | USC |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 01-OCT-2026 | DN | Z | SMS | EA | 0.0000 | $12,231.81 | 1 | U | 0 | D | 3B----- | $0.00 | N |
| 01-OCT-2026 | DS | Z | SMS | EA | 0.0000 | $12,231.81 | 1 | U | 0 | F | ------- | $0.00 | I |
Part numbers
- Part number
- J67T4XX
- CAGE
- 19857THE ELECTRIC HEATER CO DBA HUBBELL ELECTRIC HEATER CO.
- CAGE status
- A
- RNCC
- 3
- RNVC
- 2
- Document availability code
- E
- RNAAC
- ZZ
Characteristics
| HEATING ELEMENT TYPE | ANY ACCEPTABLE |
|---|---|
| FURNISHED ITEMS | ATTACHMENT DEVICE AND THERMOSTATIC SWITCH |
| OVERALL LENGTH | INCHES NOMINAL 21.000 |
| OVERALL HEIGHT | INCHES NOMINAL 19.750 |
| OVERALL WIDTH | INCHES NOMINAL 13.000 |
| SWITCH TYPE | SINGLE THROW |
| END ITEM IDENTIFICATION | DISHWASHER |
| FURNISHED ITEMS AND QUANTITY | MAGNETIC CONTACTOR 1 (C25DND315B); DIGITAL DISPLAY ELECTRONIC TEMPERATURE CONTROLLER 1 (TD1000); CONTROL MODULE 1 (T1000) WHICH IS COMPRISED THE FOLLOWING: IMMERSION COPPER ELEMENTS, IMMERSION SAFETY HI-TEMPERATURE CUT OUT WITH MANUAL RESET, LOW WATER CUT OUT, LEAK DETECTION SENSOR, ON/OFF SWITCH; THE FOLLOWING ITEMS ARE SHIPPED LOOSE WITH THE ITEM: ASME RATED COMBINATION TEMPERATURE AND PRESSURE RELIEF VALVE 1 (100XL.75 150LB), BRASS PRESSURE REDUCING VALVE WITH BUILT-IN BYPASS 1 (36A-304-02), TEMPERATURE/PRESSURE GAUGE 2 (T405), NICKEL PLATE STEEL LEGS 4 (AE61-4002-CXX) -- ALL OF THE ABOVE ITEMS ARE INCLUDED IN THIS THIS ORDER BUT CAN BE ORDERED INDIVIDUALLY AS NEEDED |
| HEATING CAPACITY PER HOUR | GALLONS 57.0 |
| TEMP RISE PER HOUR | FAHRENHEIT 50.0 |
| WATER INLET CONNECTION THREAD SIZE AND SERIES/TYPE DESIGNATOR | NPT TO 4-14 |
| WATER OUTLET CONNECTION THREAD SIZE AND SERIES/TYPE DESIGNATOR | NPT TO 4-14 |
| WATER INLET CONNECTION QUANTITY | 1 |
| WATER OUTLET CONNECTION QUANTITY | 1 |
| CAPACITY | TANK GALLONS 6.0 |
| FEATURES PROVIDED | INSULATED |
| OPERATING PRESSURE | POUNDS PER SQUARE INCH (PSI) MAXIMUM 150.0 |
| PHASE | THREE |
| SPECIAL FEATURES | OUTER JACET IS BRUSHED STAINLESS STEEL (TYPE 304L); UNIT IS FACTORY ASSEMBLED, FOAM INSULATED (POLYURETHANE FOAM), JACKETED, WIRED, AND TESTED; POWER RATING IS 7.3 KW; FULL LOAD AMPERAGE IS 8.8 AMPS; TANK TEST PRESSURE IS 225 PSI; THERMOSTAT TEMPERATURE RANGE IS 0-200 DEGREES F; HI-LIMIT TEMP SETTING IS 200 DEGREES F FIXED; RELIEF VALVE RATING IS 210 DEGREES F, 150 PSI |
| FREQUENCY IN HERTZ | 60.0 |
| MATERIAL | STEEL CORROSION RESISTING |
MOE rules
- MOE rule
- N9BZ
- MOE CD
- DN
- AMC
- 3
- AMSC
- P
- Date assigned
- 01-SEP-06
- IMC
- Z
- IMCA
- HD
- PICA
- GX
- PICA LOA
- 01
- SICA
- GH
- SICA LOA
- 5D
- Auth collab
- GX
- Supp collab
- HD
- Fmr MOE rl
- N9ZD
Service data
Navy
- COG
- 3B
Freight
- ACTY CD
- KZ
- NMFC
- 026510
- NMFC sub
- Z
- Uniform freight class
- 00000
- Less than truckload
- W
- Water commodity code
- 736
- Type of cargo code
- Z
- Special handling code
- 9
- Air dimension code
- A
- Air commodity code
- VZ
- NMF description
- SUB8 VARIABLE
Packaging
Unit and preservation
- PICA SICA
- P
- Unpackaged weight
- 0.0000
- Unpackaged width
- 0.000
- Unpackaged length
- 0.000
- Unpackaged height
- 0.000
- TOS
- B
- Intermediate container qty
- AAAQuantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
- Method of preservation
- 10Physical protection
- Clng drying
- 1Any suitable process that is not injurious to the item.
- Pres mat
- 00No requirement
- Wrap mat
- ZZSpecial requirements – see specific instructions or drawings provided
- Cush dun
- ZZSpecial requirements.
- THK
- C3/4 inch thick
- Unit cont
- D3PPP-B-566, PPP-B-676, or ASTM D5118/D5118M, folding, setup or fiberboard box.
- PKG data source
- P
Unit pack
- PICA SICA
- P
- SPC MKG
- 00No special marking
- Inter cont
- D3PPP-B-566, PPP-B-676, or ASTM D5118/D5118M, folding, setup or fiberboard box.
- Lvl A
- EPacking shall be accomplished to meet the performance test requirements of ASTM D4169, Distribution Cycle 18,...
- Lvl b
- QPacking shall be accomplished in accordance with table C-II for the packing level specified.
- Unit pack weight
- 0.0000
- UP SZ MAXB
- 0.00000
- UP SZ MAXL
- 0.00000
- UP SZ MAXH
- 0.00000
- Unit pack cube
- 0.0000
- OPI
- OOptions can be exercised as to specific method of preservation or DoD approved packaging materials to be used.
Packaging instructions
- PICA SICA
- P
- SPI date
- 00000
Related items
Standardization
- Item standardization code
- 5
- Orig stdzn dec
- 97
- Dt stdzn dec
- 26-JAN-2005
- NIIN status code
- 0
Request a quote
Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.