Catalog item
Request a quoteVALVE,CHECK
4820FSC
01NCB code
729-6518Item number
NIIN 01-729-6518
- Unit price
- $2,107.00
- Unit of issue
- EA
- Source of supply
- NRP
- DEMIL code
- Q
Identification
- Item name code
- 05487
- PINC
- 0005487
- Criticality code
- S
- II
- 0
- DEMIL code
- Q
- DEMIL integrity code
- 3
- NIIN assigned
- 19-MAY-25
- Precious metals indicator
- A
- ADP equipment code
- 0
- Hazardous material indicator
- N
- ESD/EMI code
- A
Management
| Effective date | Major organizational entity | Acquisition advice code | Source of supply | Unit of issue | Unit of measure quantity | Unit price | Quantity per unit pack | Controlled inventory item code | Shelf-life code | Recoverability code | Management control | Net price | USC |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 01-OCT-2026 | DN | J | NRP | EA | 0.0000 | $2,107.00 | 1 | U | 0 | D | 3HQ5009 | $0.00 | I |
| 01-OCT-2026 | DN | J | NRP | EA | 0.0000 | $2,107.00 | 1 | U | 0 | D | 3HQ5009 | $0.00 | N |
Part numbers
| Part number | CAGE | CAGE status | RNCC | RNVC | Document availability code | RNAAC | SADC |
|---|---|---|---|---|---|---|---|
| M24630/1-12 | 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M | A | 4 | 1 | 3 | ZZ | |
| PLC-11440/SHEET1OF3/#12 | 99565 ADMIRAL VALVE LLC DBA CPV MANUFACTURING | A | C | 1 | 1 | ZZ | AC |
| PLC-11440-12 | 99565 ADMIRAL VALVE LLC DBA CPV MANUFACTURING | A | 3 | 1 | 1 | ZZ | |
| PLC-11440 | 99565 ADMIRAL VALVE LLC DBA CPV MANUFACTURING | A | D | 9 | D | ZZ | |
| PLC-11440-12Q5 | 03950 NAVAL INVENTORY CONTROL POINT MECHANICSBURG | A | 5 | 2 | 6 | ZZ | |
| M24630/1-12Q5 | 03950 NAVAL INVENTORY CONTROL POINT MECHANICSBURG | A | 5 | 2 | 6 | ZZ |
Characteristics
| END ITEM IDENTIFICATION | CHECK VALVE IN-LINE NON REVERSIBLE 300PSI SCH |
|---|---|
| DEPARTURE FROM CITED DOCUMENT | AN ITEM THAT SUPPORTS SUBSAFE CRITICAL SYSTEMS AND REQUIRES OBJECTIVE QUALITY EVIDENCE THAT QUALITY ASSURANCE REQUIREMENTS HAVE BEEN MET, INCLUDING CERTIFICATION OF TESTS FOR HYDROSTATIC AND/OR OPERATIONAL TESTING AND ITEM SERIALIZATION TRACEABLE TO THE CERTIFICATIONS DURING INITIAL PROCUREMENT AND ANYSUBSEQUENT REPAIRS. GOVERNMENT SOURCE INSPECTION IS INVOLVED |
| PART NAME ASSIGNED BY CONTROLLING AGENCY | VALVE IN-LINE CHECK |
| CRITICALITY CODE JUSTIFICATION | ZZZW |
| PROPRIETARY CHARACTERISTICS | PACS |
MOE rules
- MOE rule
- N1H5
- MOE CD
- DN
- AMC
- 1
- AMSC
- G
- Date assigned
- 01-MAY-25
- IMC
- P
- PICA
- HD
- PICA LOA
- 06
- Auth collab
- HD
- Supp collab
- GG
Service data
Navy
- COG
- 3H
- SMIC
- Q5
- IRRC
- 00
- SMCC
- 9
Freight
- ACTY CD
- HD
Packaging
Unit and preservation
- PICA SICA
- P
- PKG cat
- ZZZ0
- Unpackaged weight
- 4.8000
- Unpackaged width
- 2.000
- Unpackaged length
- 5.200
- Unpackaged height
- 2.000
- TOS
- B
- Intermediate container qty
- AAAQuantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
- Method of preservation
- 10Physical protection
- Clng drying
- 1Any suitable process that is not injurious to the item.
- Pres mat
- 00No requirement
- Wrap mat
- 00No requirement
- Cush dun
- 00No requirement
- THK
- 0Not applicable
- Unit cont
- D4Vendor's setup or folding box.
- PKG data source
- A
Unit pack
- PICA SICA
- P
- SPC MKG
- 00No special marking
- Inter cont
- EDASTM D5118/D5118M, Type CF, Class weather resistant, corrugated fiberboard box.
- UCL
- OUnit container is not an acceptable shipping container.
- Lvl A
- EPacking shall be accomplished to meet the performance test requirements of ASTM D4169, Distribution Cycle 18,...
- Lvl b
- QPacking shall be accomplished in accordance with table C-II for the packing level specified.
- Unit pack weight
- 6.0000
- UP SZ MAXB
- 3.30000
- UP SZ MAXL
- 6.50000
- UP SZ MAXH
- 3.50000
- Unit pack cube
- 0.0430
- OPI
- OOptions can be exercised as to specific method of preservation or DoD approved packaging materials to be used.
Packaging instructions
- PICA SICA
- P
- SPI date
- 00000
Related items
Standardization
- Item standardization code
- 5
- Orig stdzn dec
- 97
- Dt stdzn dec
- 19-MAY-2025
- NIIN status code
- 0
Request a quote
Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.