Catalog item

RESISTOR,FIXED,FILM

5905FSC
00NCB code
072-0022Item number
NIIN 00-072-0022
Request a quote
Unit price
$5.05
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
05311
PINC
0005311
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
27-JUL-67
Precious metals indicator
A
ADP equipment code
0
Hazardous material indicator
N
ESD/EMI code
A
Schedule B export code
8533100042

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DFJSMSEA0.0000$5.051U0NSF9EH-N$0.00F
01-OCT-2026DNJSMSEA0.0000$5.051U09B-----$0.00N
01-OCT-2026DSJSMSEA0.0000$5.051U0N-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSCSADC
MF7CD1821F19701
NORTH AMERICAN PHILIPS CORP PHILIPS COMPONENTS DISCRETE PRODUCTS DIV
AC19TU4B
CECT0-1821F75042
TRW INC TRW ELECTRONIC COMPONENTS IRC FIXED RESISTORS PHILADELPHIA DIV
HC16ZZAC
323-0218-0080009
TEKTRONIX, INC.
AC16ZZAC
MIL-R-10509/281349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A59EZZB
MIL-PRF-10509/281349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A41EZZ
RN65F1821F81349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A223TX3D
MFF1-2T1-1821F91637
VISHAY DALE ELECTRONICS, LLC
AC16ZZAC

Characteristics

AMBIENT TEMP AT FULL RATED POWERCELSIUS 125.0
INCLOSURE TYPEENCAPSULATED
POWER DISSIPATION RATING IN WATTSFREE AIR 0.500
AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER175.0
TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS-55.0 TO 175.0
SPECIFICATION/STANDARD DATAGOVERNMENT SPECIFICATION 81349--IL-R-10509 TO 2
STYLE DESIGNATOR
TEST DATA DOCUMENTSPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 81349--IL-R-10509
RELIABILITY INDICATORNOT ESTABLISHED
BODY DIAMETERINCHES NOMINAL 0.188
BODY LENGTHINCHES NOMINAL 0.625
TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS-50.0 TO 50.0
ELECTRICAL RESISTANCEKILOHMS 1.820
RESISTANCE TOLERANCE IN PERCENT-1.000 TO 1.000
TERMINAL TYPEWIRE LEAD

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabSupp collabFmr MOE rl
YA01YA01-DEC-99YA81YA
FXGXDF1T01-APR-06ZSXGX01SX5DGX TUFXTX
N9BNDN1T01-APR-06ZGHGX01GH5DGXHDN9ND

Service data

Navy

COG
9B

Air Force

Fund
SF
Budget
9
MMAC
EH
PVC
N
ERRC
N

Freight

ACTY CD
TX
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
72D
Type of cargo code
3
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
A
Intermediate container qty
ZZZ
Special requirement: see the specific drawing or instruction provided
Method of preservation
ZZ
Special requirements apply that are not represented by the code symbols; details are provided with the acquisition...
Clng drying
Z
Special requirements - See specific instructions or drawings provided.
Pres mat
ZZ
Special requirement – See specific instructions or drawings provided
Wrap mat
ZZ
Special requirements – see specific instructions or drawings provided
Cush dun
ZZ
Special requirements.
THK
Z
Special requirements – See specific instructions or drawings provided
Unit cont
ZZ
Special requirement – See specific instructions or drawings provided.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
ZZ
Special requirements
Inter cont
ZZ
Special requirement – See specific instructions or drawings provided.
Lvl A
Z
Special requirement.
Lvl b
Z
Special requirement.
Unit pack weight
0.1000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0090
OPI
A
Packaging is in accordance with a procedural specification or an SPI.
Supplemental instructions
PRESERVATION AND PACKAGING

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
5
Orig stdzn dec
96
Dt stdzn dec
07-MAY-2012
NIIN status code
0

Cancelled and replaced NIINs

FSC
5905
Cancelled NIIN
5905-01-162-3947
NIIN status code
5
Effective date
02-JUL-2026
DEMIL code
A

Request a quote