Catalog item

RESISTOR,THERMAL

5905FSC
00NCB code
073-6663Item number
NIIN 00-073-6663
Request a quote
Unit price
$8.91
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
00309
PINC
0000309
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
01-JAN-63
Precious metals indicator
U
Hazardous material indicator
N
ESD/EMI code
B
Schedule B export code
8533400080

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DFJSMSEA0.0000$8.911U0NSF9EH-N$0.00F
01-OCT-2026DNJSMSEA0.0000$8.911U09B-----$0.00N
01-OCT-2026DSJSMSEA0.0000$8.911U0N-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSCSADC
134752-13935351
GE AVIATION SYSTEMS LLC
A32XXX3D
TM1-8-4-7K96214
RAYTHEON COMPANY DBA RAYTHEON
AC15ZZAC
TM1/8 472J96214
RAYTHEON COMPANY DBA RAYTHEON
A59ETXB
M5PCT96214
RAYTHEON COMPANY DBA RAYTHEON
AC15ZZAC
TM1/8 472J01295
TEXAS INSTRUMENTS INCORPORATED
A59ETX

Characteristics

STYLE DESIGNATOR
TERMINAL TYPE AND QUANTITYWIRE LEAD 2
AMBIENT TEMP AT FULL RATED POWERCELSIUS 100.0
MAXIMUM OPERATING TEMPCELSIUS 125.0
ZERO POWER RESISTANCE AT SPECIFIED TEMPSECOND RESISTANCE-TEMPERATURE POINT KILOHMS 2.21
ZERO POWER RESISTANCE AT SPECIFIED TEMPSEVENTH RESISTANCE-TEMPERATURE POINT KILOHMS 6.63
INCLOSURE TYPEENCAPSULATED
ZERO POWER RESISTANCEKILOHMS 4.700
ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP-5.0 TO 5.0
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-7.4 TO 7.4
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-8.0 TO 8.0
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-8.3 TO 8.3
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-8.5 TO 8.5
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-9.2 TO 9.2
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-7.2 TO 7.2
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWERSIXTH RESISTANCE-TEMPERATURE POINT CELSIUS 50.0
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWERTENTH RESISTANCE-TEMPERATURE POINT CELSIUS 150.0
ZERO POWER RESISTANCE AT SPECIFIED TEMPTHIRD RESISTANCE-TEMPERATURE POINT KILOHMS 2.52
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-10.1 TO 10.1
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-5.3 TO 5.3
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-6.6 TO 6.6
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-6.7 TO 6.7
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWERFOURTH RESISTANCE-TEMPERATURE POINT CELSIUS -25.0
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWERNINTH RESISTANCE-TEMPERATURE POINT CELSIUS 125.0
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWERSECOND RESISTANCE-TEMPERATURE POINT CELSIUS -65.0
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWERSEVENTH RESISTANCE-TEMPERATURE POINT CELSIUS 75.0
ZERO POWER RESISTANCE AT SPECIFIED TEMPSIXTH RESISTANCE-TEMPERATURE POINT KILOHMS 5.64
ZERO POWER RESISTANCE AT SPECIFIED TEMPTENTH RESISTANCE-TEMPERATURE POINT KILOHMS 10.48
RELIABILITY INDICATORNOT ESTABLISHED
TERMINAL LENGTHINCHES MINIMUM 1.000
BODY LENGTHINCHES MINIMUM 0.390 AND INCHES MAXIMUM 0.420
BODY OUTSIDE DIAMETERINCHES MINIMUM 0.125 AND INCHES MAXIMUM 0.155
TERMINAL DIAMETERINCHES NOMINAL 0.025
MAXIMUM POWER DISSIPATION RATINGMILLIWATTS 125.00
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWERFIFTH RESISTANCE-TEMPERATURE POINT CELSIUS 0.0
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWERFIRST RESISTANCE-TEMPERATURE POINT CELSIUS -75.0
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWERTHIRD RESISTANCE-TEMPERATURE POINT CELSIUS -50.0
ZERO POWER RESISTANCE AT SPECIFIED TEMPEIGHTH RESISTANCE-TEMPERATURE POINT KILOHMS 7.85
ZERO POWER RESISTANCE AT SPECIFIED TEMPFIFTH RESISTANCE-TEMPERATURE POINT KILOHMS 3.85
ZERO POWER RESISTANCE AT SPECIFIED TEMPFIRST RESISTANCE-TEMPERATURE POINT KILOHMS 2.05
ZERO POWER RESISTANCE AT SPECIFIED TEMPFOURTH RESISTANCE-TEMPERATURE POINT KILOHMS 3.1
ZERO POWER RESISTANCE AT SPECIFIED TEMPNINTH RESISTANCE-TEMPERATURE POINT KILOHMS 9.4
ZERO POWER TEMP COEFFICIENT OF RESISTANCE IN PERCENT PER DEG CELSIUS0.70
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWEREIGHTH RESISTANCE-TEMPERATURE POINT CELSIUS 100.0
THERMAL TIME CONSTANT IN SECONDS35.0
POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS2.5

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabSupp collabFmr MOE rl
ZC01ZC01-APR-91ZC81ZC
ZR01ZR01-APR-91ZR81ZR
ZU01ZU01-APR-91ZU81ZU
ZW01ZW01-APR-91ZW81ZW
FXGXDF3L01-APR-06ZSXGX01SX5DGX TUFXTX
N9BNDN3L01-APR-06ZGHGX01GH5DGXKEN9ND

Service data

Navy

COG
9B

Air Force

Fund
SF
Budget
9
MMAC
EH
PVC
N
ERRC
N

Freight

ACTY CD
XX
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
72D
Type of cargo code
3
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
41
Watervaporproof bag, heat sealed
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
00
No requirement
Cush dun
00
No requirement
THK
0
Not applicable
Unit cont
ZZ
Special requirement – See specific instructions or drawings provided.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
ZZ
Special requirements
Inter cont
D1
PPP-B-566 or PPP-B-676, folding or setup box.
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
0.0000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0000
OPI
M
All packaging data is mandatory for compliance and no substitutions are permitted.
Supplemental instructions
UNIT PACKAGE MARKING REQUI

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
82151

Full packaging code breakdown

Related items

Standardization

Item standardization code
6
Orig stdzn dec
TX
Dt stdzn dec
21-MAR-1968
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.