Catalog item

RESISTOR,THERMAL

5905FSC
00NCB code
080-6832Item number
NIIN 00-080-6832
Request a quote
Unit price
$123.00
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
00309
PINC
0000309
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
01-JAN-63
Precious metals indicator
U
Hazardous material indicator
N
ESD/EMI code
B
Schedule B export code
8533400080

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DAJSMSEA0.0000$123.001U0ZQ22QDX-$0.00A
01-OCT-2026DFJSMSEA0.0000$123.001U0NSF9EH-N$0.00F
01-OCT-2026DMJSMSEA0.0000$123.001U0Z15B2---$0.00M
01-OCT-2026DNJSMSEA0.0000$123.001U09B-----$0.00N
01-OCT-2026DSJSMSEA0.0000$123.001U0N-------$0.00I
01-OCT-2026GPJSMSEA0.0000$123.001U0-------$0.00C

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
763F8972819
OHMITE HOLDING, L.L.C.
A395ZZ
763F8910646
CESIWID INC
R593TX3B
714-1714-0013499
ROCKWELL COLLINS, INC. DBA COLLINS AEROSPACE GOVERNMENT SYSTEMS DIV COLLINS AEROSPACE - GOVERNMENT SYSTEMS
A591TX3B

Characteristics

BODY OUTSIDE DIAMETERINCHES MAXIMUM 0.219
TERMINAL DIAMETERINCHES NOMINAL 0.020
MAXIMUM POWER DISSIPATION RATINGWATTS 1.00
BODY LENGTHINCHES MAXIMUM 0.625
TERMINAL LENGTHINCHES MINIMUM 1.000
RELIABILITY INDICATORNOT ESTABLISHED
THERMAL TIME CONSTANT IN SECONDS1.8
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWERFIRST RESISTANCE-TEMPERATURE POINT CELSIUS -50.0
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWERFOURTH RESISTANCE-TEMPERATURE POINT CELSIUS 150.0
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWERSECOND RESISTANCE-TEMPERATURE POINT CELSIUS 80.0
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWERTHIRD RESISTANCE-TEMPERATURE POINT CELSIUS 110.0
ZERO POWER RESISTANCE AT SPECIFIED TEMPFIRST RESISTANCE-TEMPERATURE POINT OHMS 206.0
ZERO POWER RESISTANCE AT SPECIFIED TEMPFOURTH RESISTANCE-TEMPERATURE POINT OHMS 55.0
ZERO POWER RESISTANCE AT SPECIFIED TEMPSECOND RESISTANCE-TEMPERATURE POINT OHMS 128.0
ZERO POWER RESISTANCE AT SPECIFIED TEMPTHIRD RESISTANCE-TEMPERATURE POINT OHMS 87.0
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-15.0 TO 15.0
REFERENCE TEMP IN DEG CELSIUS25.0
STYLE DESIGNATOR
TERMINAL TYPE AND QUANTITYWIRE LEAD 2
ZERO POWER RESISTANCEOHMS 330.000
ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP-10.0 TO 10.0
INCLOSURE TYPEENCAPSULATED
AMBIENT TEMP AT FULL RATED POWERCELSIUS 25.0
MAXIMUM OPERATING TEMPCELSIUS 150.0

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabSupp collabFmr MOE rl
YA01YA01-DEC-99YA81YA
YB01YB01-APR-91YB81YB
YW01YW01-AUG-00YW81YW
ZC01ZC01-APR-91ZC81ZC
ZF01ZF01-APR-91ZF81ZF
ZG01ZG01-APR-91ZG81ZG
ZH01ZH01-APR-91ZH81ZH
ZP01ZP01-APR-91ZP81ZP
ZR01ZR01-JUL-97ZR81ZR
ZU01ZU01-APR-91ZU81ZU
ZW01ZW01-NOV-98ZW81ZW
A918DA3C01-APR-06ZCDGX01CD5DCD GXCLA196
C911GP3C01-APR-06GX01XG5DXG GXC007
FXGXDF3C01-APR-06ZSXGX01SX5DGX TUFXTX
MC49DM3C01-APR-06ZPAGX01PA5DGX PAMC13
N9BNDN3C01-APR-06ZGHGX01GH5DGXGT HD KENIND
VJ01VJ01-FEB-19VJ81VJ

Service data

Army

Matcat 1
Q
Matcat 2
2
Matcat 3
2
Matcat 4 5
QD
ARC
X

Navy

COG
9B

Air Force

Fund
SF
Budget
9
MMAC
EH
PVC
N
ERRC
N

Marine Corps

SAC
1
CEC
5
MEC
B2

Freight

ACTY CD
XX
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
72D
Type of cargo code
3
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
A
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
41
Watervaporproof bag, heat sealed
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
00
No requirement
Cush dun
00
No requirement
THK
0
Not applicable
Unit cont
D3
PPP-B-566, PPP-B-676, or ASTM D5118/D5118M, folding, setup or fiberboard box.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
ZZ
Special requirements
Inter cont
D3
PPP-B-566, PPP-B-676, or ASTM D5118/D5118M, folding, setup or fiberboard box.
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
0.1000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0090
OPI
M
All packaging data is mandatory for compliance and no substitutions are permitted.
Supplemental instructions
UNIT PACKAGE MARKING REQUI

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
6
Orig stdzn dec
TX
Dt stdzn dec
21-MAR-1968
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.