Catalog item
Request a quoteRESISTOR,THERMAL
5905FSC
00NCB code
252-1319Item number
NIIN 00-252-1319
- Unit price
- $12.82
- Unit of issue
- EA
- Source of supply
- SMS
- DEMIL code
- A
Identification
- Item name code
- 00309
- PINC
- 0000309
- Criticality code
- Y
- II
- 0
- DEMIL code
- A
- NIIN assigned
- 21-FEB-69
- Precious metals indicator
- U
- Hazardous material indicator
- N
- Schedule B export code
- 8533400080
Management
| Effective date | Major organizational entity | Acquisition advice code | Source of supply | Unit of issue | Unit of measure quantity | Unit price | Quantity per unit pack | Controlled inventory item code | Shelf-life code | Recoverability code | Management control | Net price | USC |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 01-OCT-2026 | DA | J | SMS | EA | 0.0000 | $12.82 | 1 | U | 0 | Z | Q22TPX- | $0.00 | A |
| 01-OCT-2026 | DN | J | SMS | EA | 0.0000 | $12.82 | 1 | U | 0 | 9B----- | $0.00 | N | |
| 01-OCT-2026 | DS | J | SMS | EA | 0.0000 | $12.82 | 1 | U | 0 | N | ------- | $0.00 | I |
Part numbers
- Part number
- KA35L1
- CAGE
- 73168KIDDE TECHNOLOGIES, INC DBA FENWAL SAFETY SYSTEMS DIV FENWALL SAFETY SYSTEMS
- CAGE status
- A
- RNCC
- 3
- RNVC
- 2
- Document availability code
- 6
- RNAAC
- TA
- RNFC
- 3
- RNSC
- D
Characteristics
| TERMINAL LENGTH | INCHES NOMINAL 1.500 |
|---|---|
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -12.0 TO 12.0 |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -13.4 TO 13.4 |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -13.8 TO 13.8 |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -14.6 TO 14.6 |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -15.5 TO 15.5 |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -16.6 TO 16.6 |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -17.0 TO 17.0 |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -18.9 TO 18.9 |
| INCLOSURE TYPE | UNINCLOSED |
| CUBIC MEASURE | CUBIC INCHES 0.004 |
| ZERO POWER RESISTANCE | KILOHMS 5.000 |
| BODY OUTSIDE DIAMETER | INCHES NOMINAL 0.200 |
| BODY WIDTH | INCHES NOMINAL 0.190 |
| TERMINAL DIAMETER | INCHES NOMINAL 0.020 |
| AMBIENT TEMP AT FULL RATED POWER | CELSIUS 25.0 |
| MAXIMUM OPERATING TEMP | CELSIUS 300.0 |
| THERMAL TIME CONSTANT IN SECONDS | 35.0 |
| POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS | 7.0 |
| ZERO POWER TEMP COEFFICIENT OF RESISTANCE IN PERCENT PER DEG CELSIUS | M4.40 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | EIGHTH RESISTANCE-TEMPERATURE POINT CELSIUS 150.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | FIFTH RESISTANCE-TEMPERATURE POINT CELSIUS 60.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | FIRST RESISTANCE-TEMPERATURE POINT CELSIUS -60.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | FOURTH RESISTANCE-TEMPERATURE POINT CELSIUS 30.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | NINTH RESISTANCE-TEMPERATURE POINT CELSIUS 200.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | SECOND RESISTANCE-TEMPERATURE POINT CELSIUS -30.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | SEVENTH RESISTANCE-TEMPERATURE POINT CELSIUS 120.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | SIXTH RESISTANCE-TEMPERATURE POINT CELSIUS 90.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | TENTH RESISTANCE-TEMPERATURE POINT CELSIUS 300.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | THIRD RESISTANCE-TEMPERATURE POINT CELSIUS 0.0 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | EIGHTH RESISTANCE-TEMPERATURE POINT OHMS 93.0 |
| ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP | -10.0 TO 10.0 |
| CRITICALITY CODE JUSTIFICATION | AEJE |
| REFERENCE TEMP IN DEG CELSIUS | 25.0 |
| SURFACE TREATMENT | TERMINAL SOLDER |
| STYLE DESIGNATOR | |
| TERMINAL TYPE AND QUANTITY | WIRE LEAD 2 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | SECOND RESISTANCE-TEMPERATURE POINT KILOHMS 88.5 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | SEVENTH RESISTANCE-TEMPERATURE POINT OHMS 199.1 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | SIXTH RESISTANCE-TEMPERATURE POINT OHMS 457.6 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | TENTH RESISTANCE-TEMPERATURE POINT OHMS 7.0 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | THIRD RESISTANCE-TEMPERATURE POINT KILOHMS 16.3 |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -10.4 TO 10.4 |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -11.5 TO 11.5 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | FOURTH RESISTANCE-TEMPERATURE POINT KILOHMS 4.0 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | NINTH RESISTANCE-TEMPERATURE POINT OHMS 32.8 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | FIFTH RESISTANCE-TEMPERATURE POINT KILOHMS 1.2 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | FIRST RESISTANCE-TEMPERATURE POINT KILOHMS 702.4 |
MOE rules
| MOE rule | MOE CD | AMC | AMSC | Date assigned | IMC | IMCA | PICA | PICA LOA | SICA | SICA LOA | Auth collab | Supp collab | Fmr MOE rl |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ZR01 | ZR | 01-DEC-07 | ZR | 81 | ZR | ||||||||
| ZW01 | ZW | 01-NOV-05 | ZW | 81 | ZW | ||||||||
| A918 | DA | 3 | D | 01-APR-06 | Z | CD | GX | 01 | CD | 5D | CD GX | CL | A196 |
| N9BN | DN | 3 | D | 01-APR-06 | Z | GH | GX | 01 | GH | 5D | GX | KE HD | N9ND |
Service data
Army
- Matcat 1
- Q
- Matcat 2
- 2
- Matcat 3
- 2
- Matcat 4 5
- TP
- ARC
- X
Navy
- COG
- 9B
Freight
- ACTY CD
- TX
- NMFC
- 061700
- NMFC sub
- Z
- Uniform freight class
- 34580
- Less than truckload
- W
- Water commodity code
- 72D
- Type of cargo code
- Z
- Special handling code
- 9
- Air dimension code
- A
- Air commodity code
- HZ
- NMF description
- ELEC APPLIANCES/INSTRUMENTS NOI
Packaging
Unit and preservation
- PICA SICA
- P
- PKG cat
- 69F0
- Unpackaged weight
- 0.0000
- Unpackaged width
- 0.000
- Unpackaged length
- 0.000
- Unpackaged height
- 0.000
- TOS
- A
- Intermediate container qty
- AAAQuantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
- Method of preservation
- 41Watervaporproof bag, heat sealed
- Clng drying
- 1Any suitable process that is not injurious to the item.
- Pres mat
- 00No requirement
- Wrap mat
- DAA-A-1249, paper, tissue
- Cush dun
- 00No requirement
- THK
- 0Not applicable
- Unit cont
- D3PPP-B-566, PPP-B-676, or ASTM D5118/D5118M, folding, setup or fiberboard box.
- PKG data source
- P
Unit pack
- PICA SICA
- P
- SPC MKG
- ZZSpecial requirements
- Inter cont
- D1PPP-B-566 or PPP-B-676, folding or setup box.
- Lvl A
- QPacking shall be accomplished in accordance with table C.II for the packing level specified.
- Lvl b
- QPacking shall be accomplished in accordance with table C-II for the packing level specified.
- Unit pack weight
- 0.1000
- UP SZ MAXB
- 0.00000
- UP SZ MAXL
- 0.00000
- UP SZ MAXH
- 0.00000
- Unit pack cube
- 0.0030
- OPI
- MAll packaging data is mandatory for compliance and no substitutions are permitted.
- Supplemental instructions
- UNIT PACKAGE MARKING REQUI
Packaging instructions
- PICA SICA
- P
- PKG design ACTY
- 14933
- SPI date
- 00000
Related items
Standardization
- Item standardization code
- 2
- Orig stdzn dec
- TX
- Dt stdzn dec
- 08-SEP-1971
- NIIN status code
- 0
Request a quote
Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.