Catalog item
Request a quoteRESISTOR,THERMAL
5905FSC
00NCB code
476-1363Item number
NIIN 00-476-1363
- Unit price
- $41.24
- Unit of issue
- EA
- Source of supply
- SMS
- DEMIL code
- A
Identification
- Item name code
- 00309
- PINC
- 0000309
- Criticality code
- X
- II
- M
- DEMIL code
- A
- DEMIL integrity code
- 1
- NIIN assigned
- 01-JAN-63
- Precious metals indicator
- U
- Hazardous material indicator
- N
- ESD/EMI code
- A
- Schedule B export code
- 8533400080
Management
| Effective date | Major organizational entity | Acquisition advice code | Source of supply | Unit of issue | Unit of measure quantity | Unit price | Quantity per unit pack | Controlled inventory item code | Shelf-life code | Recoverability code | Management control | Net price | USC |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 01-OCT-2026 | DA | J | SMS | EA | 0.0000 | $41.24 | 1 | U | 0 | Z | Q22TPX- | $0.00 | A |
| 01-OCT-2026 | DF | J | SMS | EA | 0.0000 | $41.24 | 1 | U | 0 | N | SF9EH-N | $0.00 | F |
| 01-OCT-2026 | DN | J | SMS | EA | 0.0000 | $41.24 | 1 | U | 0 | 9B----- | $0.00 | N | |
| 01-OCT-2026 | DS | J | SMS | EA | 0.0000 | $41.24 | 1 | U | 0 | N | ------- | $0.00 | I |
Part numbers
| Part number | CAGE | CAGE status | RNCC | RNVC | Document availability code | RNAAC | RNFC | RNSC | SADC |
|---|---|---|---|---|---|---|---|---|---|
| 714-2354-000 | 56866 QUALITY THERMISTOR, INC DBA QTI | A | 5 | 2 | 5 | ZZ | |||
| 051138-0005 | 65597 THALES USA, INC. DIV AIR MOBILITY SOLUTIONS ("AMS") | A | C | 1 | 4 | 48 | AH | ||
| 714-2354-000 | 95104 ALCATEL-LUCENT HOLDINGS INC. | A | 5 | 9 | 5 | TX | 3 | B | |
| 714-2354-00 | 95104 ALCATEL-LUCENT HOLDINGS INC. | A | 5 | 9 | 5 | TX | B | ||
| 410193-391 | 96214 RAYTHEON COMPANY DBA RAYTHEON | A | 5 | 2 | 5 | TX | 3 | D | |
| TM1/4 391K | 01295 TEXAS INSTRUMENTS INCORPORATED | A | 3 | 9 | E | TX | |||
| 181-102-2 | 17671 TELEVISONET, INC. | H | C | 1 | 5 | 48 | 3 | D |
Characteristics
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | FIFTH RESISTANCE-TEMPERATURE POINT CELSIUS 0.0 |
|---|---|
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | FOURTH RESISTANCE-TEMPERATURE POINT CELSIUS -25.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | NINTH RESISTANCE-TEMPERATURE POINT CELSIUS 125.0 |
| TERMINAL DIAMETER | INCHES NOMINAL 0.025 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | FIRST RESISTANCE-TEMPERATURE POINT CELSIUS -75.0 |
| ZERO POWER TEMP COEFFICIENT OF RESISTANCE IN PERCENT PER DEG CELSIUS | 0.70 |
| MAXIMUM POWER DISSIPATION RATING | MILLIWATTS 250.00 |
| AMBIENT TEMP AT FULL RATED POWER | CELSIUS 100.0 |
| MAXIMUM OPERATING TEMP | CELSIUS 150.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | EIGHTH RESISTANCE-TEMPERATURE POINT CELSIUS 100.0 |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| TERMINAL LENGTH | INCHES NOMINAL 1.500 |
| BODY LENGTH | INCHES NOMINAL 0.585 |
| BODY OUTSIDE DIAMETER | INCHES NOMINAL 0.200 |
| THERMAL TIME CONSTANT IN SECONDS | 54.0 |
| POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS | 5.0 |
| STYLE DESIGNATOR | |
| TERMINAL TYPE AND QUANTITY | WIRE LEAD 2 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | FOURTH RESISTANCE-TEMPERATURE POINT OHMS 265.2 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | NINTH RESISTANCE-TEMPERATURE POINT OHMS 760.5 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | SECOND RESISTANCE-TEMPERATURE POINT OHMS 191.1 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | SEVENTH RESISTANCE-TEMPERATURE POINT OHMS 546.0 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | SIXTH RESISTANCE-TEMPERATURE POINT OHMS 460.2 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | TENTH RESISTANCE-TEMPERATURE POINT OHMS 858.0 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | THIRD RESISTANCE-TEMPERATURE POINT OHMS 218.4 |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -10.3 TO 10.3 |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -12.1 TO 12.1 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | SECOND RESISTANCE-TEMPERATURE POINT CELSIUS -65.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | SEVENTH RESISTANCE-TEMPERATURE POINT CELSIUS 75.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | SIXTH RESISTANCE-TEMPERATURE POINT CELSIUS 50.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | TENTH RESISTANCE-TEMPERATURE POINT CELSIUS 150.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | THIRD RESISTANCE-TEMPERATURE POINT CELSIUS -50.0 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | EIGHTH RESISTANCE-TEMPERATURE POINT OHMS 635.7 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | FIFTH RESISTANCE-TEMPERATURE POINT OHMS 323.7 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | FIRST RESISTANCE-TEMPERATURE POINT OHMS 175.5 |
| REFERENCE TEMP IN DEG CELSIUS | 25.0 |
| SURFACE TREATMENT | TERMINAL SOLDER |
| ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP | -10.0 TO 10.0 |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -18.5 TO 18.5 |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -20.0 TO 20.0 |
| INCLOSURE TYPE | ENCAPSULATED |
| ZERO POWER RESISTANCE | OHMS 390.000 |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -16.1 TO 16.1 |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -16.2 TO 16.2 |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -14.6 TO 14.6 |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -15.0 TO 15.0 |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -12.8 TO 12.8 |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -14.3 TO 14.3 |
MOE rules
| MOE rule | MOE CD | AMC | AMSC | Date assigned | IMC | IMCA | PICA | PICA LOA | SICA | SICA LOA | Auth collab | Supp collab | Fmr MOE rl |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| YJ01 | YJ | 01-APR-91 | YJ | 81 | YJ | ||||||||
| ZR01 | ZR | 01-JUL-97 | ZR | 81 | ZR | ||||||||
| ZU01 | ZU | 01-APR-91 | ZU | 81 | ZU | ||||||||
| A918 | DA | 3 | D | 01-APR-06 | Z | CD | GX | 01 | CD | 5D | CD GX | CL | A196 |
| BGX1 | GE | 3 | D | 01-APR-06 | GX | 01 | 48 | 5D | GX 48 | BTX1 | |||
| FXGX | DF | 3 | D | 01-APR-06 | Z | SX | GX | 01 | SX | 5D | GX TU | FXTX | |
| N9BN | DN | 3 | D | 01-APR-06 | Z | GH | GX | 01 | GH | 5D | GX | KE HD | NIND |
Service data
Army
- Matcat 1
- Q
- Matcat 2
- 2
- Matcat 3
- 2
- Matcat 4 5
- TP
- ARC
- X
Navy
- COG
- 9B
Air Force
- Fund
- SF
- Budget
- 9
- MMAC
- EH
- PVC
- N
- ERRC
- N
Freight
- ACTY CD
- XX
- NMFC
- 061700
- NMFC sub
- Z
- Uniform freight class
- 34580
- Less than truckload
- W
- Water commodity code
- 658
- Type of cargo code
- Z
- Special handling code
- 9
- Air dimension code
- A
- Air commodity code
- HZ
- NMF description
- ELEC APPLIANCES/INSTRUMENTS NOI
Packaging
Unit and preservation
- PICA SICA
- P
- PKG cat
- 69F0
- Unpackaged weight
- 0.0000
- Unpackaged width
- 0.000
- Unpackaged length
- 0.000
- Unpackaged height
- 0.000
- TOS
- A
- Intermediate container qty
- 100100 unit packs per intermediate container
- Method of preservation
- 41Watervaporproof bag, heat sealed
- Clng drying
- 1Any suitable process that is not injurious to the item.
- Pres mat
- 00No requirement
- Wrap mat
- 00No requirement
- Cush dun
- NAPPP-C-795, closed cell plastic cushioning; or A-A-3129, open cell plastic cushioning; or PPP-C-1797, polypropylene...
- THK
- A1/4 inch thick
- Unit cont
- BSMIL-DTL-117, Type I, Class E, Style 1, heavy duty, watervaporproof, greaseproof, opaque bag.
- PKG data source
- P
Unit pack
- PICA SICA
- P
- SPC MKG
- ZZSpecial requirements
- Inter cont
- E5ASTM D5118/D5118M, fiberboard box.
- Lvl A
- QPacking shall be accomplished in accordance with table C.II for the packing level specified.
- Lvl b
- QPacking shall be accomplished in accordance with table C-II for the packing level specified.
- Unit pack weight
- 0.1000
- UP SZ MAXB
- 0.00000
- UP SZ MAXL
- 0.00000
- UP SZ MAXH
- 0.00000
- Unit pack cube
- 0.0090
- OPI
- MAll packaging data is mandatory for compliance and no substitutions are permitted.
- Supplemental instructions
- UNIT PACKAGE MARKING REQUI
Packaging instructions
- PICA SICA
- P
- PKG design ACTY
- 14933
- SPI date
- 00000
Related items
Standardization
- Item standardization code
- 2
- Orig stdzn dec
- TX
- Dt stdzn dec
- 03-JAN-1971
- NIIN status code
- 0
Cancelled and replaced NIINs
| FSC | Cancelled NIIN | NIIN status code | Effective date | DEMIL code |
|---|---|---|---|---|
| 5905 | 5905-00-085-1951 | 7 | 02-JUL-2026 | A |
| 5905 | 5905-00-955-5698 | 7 | 02-JUL-2026 | A |
Request a quote
Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.