Catalog item

RESISTOR,VARIABLE,NONWIRE WOUND,

5905FSC
00NCB code
552-5294Item number
NIIN 00-552-5294
Request a quote
Unit price
$35.81
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
37405
PINC
0037405
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
24-OCT-74
Precious metals indicator
U
Hazardous material indicator
N
ESD/EMI code
B
Schedule B export code
8533400080

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DAJSMSEA0.0000$35.811U0ZQ2200X-$0.00A
01-OCT-2026DFJSMSEA0.0000$35.811U0NSF9EH-N$0.00F
01-OCT-2026DNJSMSEA0.0000$35.811U09B-----$0.00N
01-OCT-2026DSJSMSEA0.0000$35.811U0N-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
3329W-1-25132997
BOURNS INC
A525ZZ
3329W-L58-25132997
BOURNS INC
A593TX4D
82PAR250-199B73138
BI TECHNOLOGIES CORPORATION DIV BI TECHNOLOGIES CORP.
A525ZZ
82PAR250-199A73138
BI TECHNOLOGIES CORPORATION DIV BI TECHNOLOGIES CORP.
A595TX
311-1278-0080009
TEKTRONIX, INC.
A321TX3D

Characteristics

MOUNTING METHODTERMINAL
ELECTRICAL RESISTANCE PER SECTIONOHMS SINGLE SECTION 250.0
ROTARY ACTUATOR TRAVEL IN ANGULAR DEGNOMINAL 270.0
CENTER TO CENTER DISTANCE BETWEEN CENTER TERMINAL AND OUTSIDE TERMINALINCHES MINIMUM 0.090 AND INCHES MAXIMUM 0.110
AMBIENT TEMP IN DEG CELSIUS PER SECTION AT ZERO PERCENT RATED POWERSINGLE SECTION 125.0
TERMINAL LOCATIONLOWER ADJACENT SIDE SINGLE ROW
EFFECTIVE ELECTRICAL ROTATION IN DEG ANGULAR ROTATIONNOMINAL 270.0
CENTER TO CENTER DISTANCE BETWEEN TERMINALSINCHES MINIMUM 0.180 AND INCHES MAXIMUM 0.220
SECTION QUANTITY1
BODY STYLE
RELIABILITY INDICATORNOT ESTABLISHED
TERMINAL LENGTHINCHES MINIMUM 0.250
BODY DIAMETERINCHES NOMINAL 0.250
BODY LENGTHINCHES NOMINAL 0.250
ACTUATOR TYPEFLUSH DRIVE WITH SLOT-HOLE
POWER DISSIPATION RATING PER SECTION IN WATTSFREE AIR SINGLE SECTION 0.5
ACTUATOR TRAVEL CONTROL FEATURESTOPS
TEMP COEFFICIENT OF RESISTANCE PER SECTION IN PPM PER DEG CELSIUSSINGLE SECTION -100.0 TO 100.0
RESISTANCE TOLERANCE PER SECTION IN PERCENTSINGLE SECTION -10.0 TO 10.0
TERMINAL TYPE AND QUANTITYPIN 3
AMBIENT TEMP IN DEG CELSIUS PER SECTION AT FULL RATED POWERSINGLE SECTION 85.0

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAAcquisition advice codePICAPICA LOASICASICA LOAAuth collabSupp collabFmr MOE rl
YB01YB01-APR-91YB81YB
ZC01ZC01-APR-91ZC81ZC
ZW01ZW01-NOV-98ZW81ZW
A918DA3L01-APR-06ZCDGX01CD5DCD GXCL BDA196
FXGXDF3L01-APR-06ZSXGX01SX5DGX TUFXTX
G860T10001-APR-91C864875 86
N9BNDN3L01-APR-06ZKEGX01GH5DGXKE HDN9ND
VJ01VJ01-DEC-18VJ81VJ

Service data

Army

Matcat 1
Q
Matcat 2
2
Matcat 3
2
Matcat 4 5
00
ARC
X

Navy

COG
9B

Air Force

Fund
SF
Budget
9
MMAC
EH
PVC
N
ERRC
N

Freight

ACTY CD
TX
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
72D
Type of cargo code
3
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
A
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
ZZ
Special requirements apply that are not represented by the code symbols; details are provided with the acquisition...
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
ZZ
Special requirement – See specific instructions or drawings provided
Wrap mat
ZZ
Special requirements – see specific instructions or drawings provided
Cush dun
ZZ
Special requirements.
THK
C
3/4 inch thick
Unit cont
ZZ
Special requirement – See specific instructions or drawings provided.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
ZZ
Special requirements
Inter cont
ZZ
Special requirement – See specific instructions or drawings provided.
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
0.0000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0020
OPI
M
All packaging data is mandatory for compliance and no substitutions are permitted.
Supplemental instructions
PRESERVATION AND PACKAGING

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
2
Orig stdzn dec
TX
Dt stdzn dec
01-DEC-1974
NIIN status code
0

Cancelled and replaced NIINs

FSC
5905
Cancelled NIIN
5905-01-013-4374
NIIN status code
5
Effective date
02-JUL-2026
DEMIL code
A

Request a quote