Catalog item

RESISTOR,THERMAL

5905FSC
00NCB code
660-3670Item number
NIIN 00-660-3670
Request a quote
Unit price
$2.67
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
00309
PINC
0000309
Criticality code
X
II
0
DEMIL code
A
NIIN assigned
01-JAN-63
Precious metals indicator
U
Hazardous material indicator
N
Schedule B export code
8533400080
FedMall
Y

Management

Effective date
01-OCT-2026
Major organizational entity
DS
Acquisition advice code
J
Source of supply
SMS
Unit of issue
EA
Unit of measure quantity
0.0000
Unit price
$2.67
Quantity per unit pack
1
Controlled inventory item code
U
Shelf-life code
0
Management control
-------
Net price
$0.00
USC
I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
D104A24446
GENERAL ELECTRIC COMPANY
A52XXX3D
2D10424446
GENERAL ELECTRIC COMPANY
A32XXX3D
D10424446
GENERAL ELECTRIC COMPANY
A31XXX3D
D104A03508
GENERAL ELECTRIC CO SEMI-CONDUCTOR PRODUCTS DEPT
H59XXX3B

Characteristics

MAXIMUM OPERATING TEMPCELSIUS 150.0
POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS4.0
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-12.6 TO 12.6
AMBIENT TEMP AT FULL RATED POWERCELSIUS 25.0
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWERSIXTH RESISTANCE-TEMPERATURE POINT CELSIUS 50.0
THERMAL TIME CONSTANT IN SECONDS6.0
CUBIC MEASURECUBIC INCHES 0.0002
ZERO POWER RESISTANCEOHMS 500.000
RELIABILITY INDICATORNOT ESTABLISHED
TERMINAL LENGTHINCHES NOMINAL 1.250
BODY OUTSIDE DIAMETERINCHES NOMINAL 0.100
BODY WIDTHINCHES NOMINAL 0.035
TERMINAL DIAMETERINCHES NOMINAL 0.013
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWERTENTH RESISTANCE-TEMPERATURE POINT CELSIUS 150.0
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWERFOURTH RESISTANCE-TEMPERATURE POINT CELSIUS 0.0
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWERNINTH RESISTANCE-TEMPERATURE POINT CELSIUS 125.0
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWERSECOND RESISTANCE-TEMPERATURE POINT CELSIUS -40.0
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWERSEVENTH RESISTANCE-TEMPERATURE POINT CELSIUS 75.0
ZERO POWER RESISTANCE AT SPECIFIED TEMPSEVENTH RESISTANCE-TEMPERATURE POINT OHMS 90.0
ZERO POWER RESISTANCE AT SPECIFIED TEMPSIXTH RESISTANCE-TEMPERATURE POINT OHMS 205.0
ZERO POWER RESISTANCE AT SPECIFIED TEMPTENTH RESISTANCE-TEMPERATURE POINT OHMS 15.0
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWERFIRST RESISTANCE-TEMPERATURE POINT CELSIUS -55.0
STYLE DESIGNATOR
TERMINAL TYPE AND QUANTITYWIRE LEAD 2
INCLOSURE TYPEENCAPSULATED
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-16.6 TO 16.6
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWEREIGHTH RESISTANCE-TEMPERATURE POINT CELSIUS 104.4
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWERFIFTH RESISTANCE-TEMPERATURE POINT CELSIUS 37.8
REFERENCE TEMP IN DEG CELSIUS25.0
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWERTHIRD RESISTANCE-TEMPERATURE POINT CELSIUS -21.5
ZERO POWER RESISTANCE AT SPECIFIED TEMPEIGHTH RESISTANCE-TEMPERATURE POINT OHMS 41.0
ZERO POWER RESISTANCE AT SPECIFIED TEMPFIFTH RESISTANCE-TEMPERATURE POINT OHMS 300.0
ZERO POWER RESISTANCE AT SPECIFIED TEMPFIRST RESISTANCE-TEMPERATURE POINT KILOHMS 27.0
ZERO POWER RESISTANCE AT SPECIFIED TEMPFOURTH RESISTANCE-TEMPERATURE POINT KILOHMS 1.4
ZERO POWER RESISTANCE AT SPECIFIED TEMPNINTH RESISTANCE-TEMPERATURE POINT OHMS 25.2
ZERO POWER RESISTANCE AT SPECIFIED TEMPSECOND RESISTANCE-TEMPERATURE POINT KILOHMS 10.8
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-18.9 TO 18.9
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-20.1 TO 20.1
ZERO POWER RESISTANCE AT SPECIFIED TEMPTHIRD RESISTANCE-TEMPERATURE POINT KILOHMS 4.0
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-16.9 TO 16.9
SURFACE TREATMENTTERMINAL SOLDER
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-13.7 TO 13.7
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-14.2 TO 14.2
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-15.1 TO 15.1
ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP-10.0 TO 10.0
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-17.8 TO 17.8

MOE rules

MOE rule
DGX1
MOE CD
DS
AMC
3
AMSC
Z
Date assigned
01-JUL-05
PICA
GX
PICA LOA
01
Auth collab
GX
Supp collab
TX
Fmr MOE rl
DTX1

Freight

ACTY CD
XX
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
658
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
A
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
ZZ
Special requirements apply that are not represented by the code symbols; details are provided with the acquisition...
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
ZZ
Special requirement – See specific instructions or drawings provided
Wrap mat
ZZ
Special requirements – see specific instructions or drawings provided
Cush dun
ZZ
Special requirements.
THK
C
3/4 inch thick
Unit cont
ZZ
Special requirement – See specific instructions or drawings provided.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
ZZ
Special requirements
Inter cont
ZZ
Special requirement – See specific instructions or drawings provided.
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
0.0000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0000
OPI
M
All packaging data is mandatory for compliance and no substitutions are permitted.
Supplemental instructions
PRESERVATION AND PACKAGING

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
6
Orig stdzn dec
TX
Dt stdzn dec
21-MAR-1968
NIIN status code
0

Cancelled and replaced NIINs

FSCCancelled NIINNIIN status codeEffective dateDEMIL code
59055905-00-552-2503701-JUL-2026A
59055905-00-962-8554702-JUL-2026A
59055905-00-812-1943702-JUL-2026A

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.