Catalog item
Request a quoteRESISTOR,THERMAL
5905FSC
00NCB code
865-8081Item number
NIIN 00-865-8081
- Unit price
- $108.89
- Unit of issue
- EA
- Source of supply
- SMS
- DEMIL code
- A
Identification
- Item name code
- 00309
- PINC
- 0000309
- Criticality code
- X
- II
- 0
- DEMIL code
- A
- DEMIL integrity code
- 1
- NIIN assigned
- 01-JAN-62
- Precious metals indicator
- U
- Hazardous material indicator
- N
- ESD/EMI code
- B
- Schedule B export code
- 8533400080
Management
| Effective date | Major organizational entity | Acquisition advice code | Source of supply | Unit of issue | Unit of measure quantity | Unit price | Quantity per unit pack | Controlled inventory item code | Shelf-life code | Recoverability code | Management control | Net price | USC |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 01-OCT-2026 | DN | J | SMS | EA | 0.0000 | $108.89 | 1 | U | 0 | 9B----- | $0.00 | N | |
| 01-OCT-2026 | DS | J | SMS | EA | 0.0000 | $108.89 | 1 | U | 0 | N | ------- | $0.00 | I |
| 01-OCT-2026 | GP | J | SMS | EA | 0.0000 | $108.89 | 1 | U | 0 | ------- | $0.00 | C |
Part numbers
| Part number | CAGE | CAGE status | RNCC | RNVC | Document availability code | RNAAC | RNFC | RNSC | SADC |
|---|---|---|---|---|---|---|---|---|---|
| 997H | 72819 OHMITE HOLDING, L.L.C. | A | C | 1 | 5 | ZZ | 3 | D | 9F |
| 99742 | 72819 OHMITE HOLDING, L.L.C. | A | 3 | 9 | X | XX | 3 | D | |
| 997H | 10646 CESIWID INC | R | 5 | 9 | X | XX | 3 | B | |
| 997H2 | 10646 CESIWID INC | R | 5 | 9 | X | XX | 3 | B | |
| 99742 | 10646 CESIWID INC | R | 5 | 9 | X | XX | 3 | B | |
| 714-1726-00REVZ | 13499 ROCKWELL COLLINS, INC. DBA COLLINS AEROSPACE GOVERNMENT SYSTEMS DIV COLLINS AEROSPACE - GOVERNMENT SYSTEMS | A | 5 | 9 | X | XX | 3 | D | |
| 714-1712 | 13499 ROCKWELL COLLINS, INC. DBA COLLINS AEROSPACE GOVERNMENT SYSTEMS DIV COLLINS AEROSPACE - GOVERNMENT SYSTEMS | A | 5 | 9 | A | ZZ | B | ||
| 714-17266-000 | 13499 ROCKWELL COLLINS, INC. DBA COLLINS AEROSPACE GOVERNMENT SYSTEMS DIV COLLINS AEROSPACE - GOVERNMENT SYSTEMS | A | 7 | 2 | A | ZZ |
Characteristics
| ZERO POWER RESISTANCE | OHMS 5.000 |
|---|---|
| ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP | -10.0 TO 10.0 |
| REFERENCE TEMP IN DEG CELSIUS | 25.0 |
| CUBIC MEASURE | CUBIC INCHES 0.004 |
| INCLOSURE TYPE | ENCAPSULATED |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -21.7 TO 21.7 |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| TERMINAL LENGTH | INCHES NOMINAL 1.500 |
| BODY LENGTH | INCHES NOMINAL 0.328 |
| BODY OUTSIDE DIAMETER | INCHES NOMINAL 0.141 |
| TERMINAL DIAMETER | INCHES NOMINAL 0.020 |
| AMBIENT TEMP AT FULL RATED POWER | CELSIUS 25.0 |
| MAXIMUM OPERATING TEMP | CELSIUS 150.0 |
| THERMAL TIME CONSTANT IN SECONDS | 10.0 |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -15.1 TO 15.1 |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -15.2 TO 15.2 |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -16.9 TO 16.9 |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -18.4 TO 18.4 |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -18.9 TO 18.9 |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -20.6 TO 20.6 |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -20.9 TO 20.9 |
| POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS | 6.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | EIGHTH RESISTANCE-TEMPERATURE POINT CELSIUS 100.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | FIFTH RESISTANCE-TEMPERATURE POINT CELSIUS 40.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | FIRST RESISTANCE-TEMPERATURE POINT CELSIUS -40.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | FOURTH RESISTANCE-TEMPERATURE POINT CELSIUS 20.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | NINTH RESISTANCE-TEMPERATURE POINT CELSIUS 120.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | SECOND RESISTANCE-TEMPERATURE POINT CELSIUS -20.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | SEVENTH RESISTANCE-TEMPERATURE POINT CELSIUS 80.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | SIXTH RESISTANCE-TEMPERATURE POINT CELSIUS 60.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | TENTH RESISTANCE-TEMPERATURE POINT CELSIUS 140.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | THIRD RESISTANCE-TEMPERATURE POINT CELSIUS 0.0 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | EIGHTH RESISTANCE-TEMPERATURE POINT OHMS 419.6 |
| SURFACE TREATMENT | TERMINAL SOLDER |
| STYLE DESIGNATOR | |
| TERMINAL TYPE AND QUANTITY | WIRE LEAD 2 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | NINTH RESISTANCE-TEMPERATURE POINT OHMS 211.1 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | SECOND RESISTANCE-TEMPERATURE POINT KILOHMS 29.9 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | FIRST RESISTANCE-TEMPERATURE POINT KILOHMS 82.5 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | FOURTH RESISTANCE-TEMPERATURE POINT KILOHMS 6.5 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | SEVENTH RESISTANCE-TEMPERATURE POINT OHMS 600.0 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | SIXTH RESISTANCE-TEMPERATURE POINT KILOHMS 1.8 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | TENTH RESISTANCE-TEMPERATURE POINT OHMS 99.6 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | THIRD RESISTANCE-TEMPERATURE POINT KILOHMS 12.6 |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -11.1 TO 11.1 |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -13.4 TO 13.4 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | FIFTH RESISTANCE-TEMPERATURE POINT KILOHMS 3.2 |
MOE rules
| MOE rule | MOE CD | AMC | AMSC | Date assigned | IMC | IMCA | PICA | PICA LOA | SICA | SICA LOA | Auth collab | Supp collab | Fmr MOE rl |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| WB01 | WB | 01-FEB-05 | WB | 81 | WB | ||||||||
| YA01 | YA | 01-OCT-00 | YA | 81 | YA | ||||||||
| YB01 | YB | 01-APR-91 | YB | 81 | YB | ||||||||
| YW01 | YW | 01-JUL-93 | YW | 81 | YW | ||||||||
| ZE01 | ZE | 01-APR-91 | ZE | 81 | ZE | ||||||||
| ZC01 | ZC | 01-APR-91 | ZC | 81 | ZC | ||||||||
| ZF01 | ZF | 01-APR-91 | ZF | 81 | ZF | ||||||||
| ZG01 | ZG | 01-APR-91 | ZG | 81 | ZG | ||||||||
| ZH01 | ZH | 01-APR-91 | ZH | 81 | ZH | ||||||||
| ZP01 | ZP | 01-APR-91 | ZP | 81 | ZP | ||||||||
| ZR01 | ZR | 01-JUL-97 | ZR | 81 | ZR | ||||||||
| ZU01 | ZU | 01-APR-91 | ZU | 81 | ZU | ||||||||
| ZW01 | ZW | 01-NOV-98 | ZW | 81 | ZW | ||||||||
| C911 | GP | 1 | G | 01-APR-06 | GX | 01 | XG | 5D | XG GX | C007 | |||
| N9BN | DN | 1 | G | 01-APR-06 | Z | GH | GX | 01 | GH | 5D | GX | KE HD GT | NIND |
| VJ01 | VJ | 01-DEC-18 | VJ | 81 | VJ |
Service data
Navy
- COG
- 9B
Freight
- ACTY CD
- XX
- NMFC
- 061700
- NMFC sub
- Z
- Uniform freight class
- 34580
- Less than truckload
- W
- Water commodity code
- 72D
- Type of cargo code
- 3
- Special handling code
- 9
- Air dimension code
- A
- Air commodity code
- HZ
- NMF description
- ELEC APPLIANCES/INSTRUMENTS NOI
Packaging
Unit and preservation
- PICA SICA
- P
- PKG cat
- 69F0
- Unpackaged weight
- 0.0000
- Unpackaged width
- 0.000
- Unpackaged length
- 0.000
- Unpackaged height
- 0.000
- TOS
- A
- Intermediate container qty
- AAAQuantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
- Method of preservation
- 41Watervaporproof bag, heat sealed
- Clng drying
- 1Any suitable process that is not injurious to the item.
- Pres mat
- 00No requirement
- Wrap mat
- 00No requirement
- Cush dun
- 00No requirement
- THK
- 0Not applicable
- Unit cont
- D3PPP-B-566, PPP-B-676, or ASTM D5118/D5118M, folding, setup or fiberboard box.
- PKG data source
- P
Unit pack
- PICA SICA
- P
- SPC MKG
- ZZSpecial requirements
- Inter cont
- D1PPP-B-566 or PPP-B-676, folding or setup box.
- Lvl A
- QPacking shall be accomplished in accordance with table C.II for the packing level specified.
- Lvl b
- QPacking shall be accomplished in accordance with table C-II for the packing level specified.
- Unit pack weight
- 0.1000
- UP SZ MAXB
- 0.00000
- UP SZ MAXL
- 0.00000
- UP SZ MAXH
- 0.00000
- Unit pack cube
- 0.0010
- OPI
- MAll packaging data is mandatory for compliance and no substitutions are permitted.
- Supplemental instructions
- UNIT PACKAGE MARKING REQUI
Packaging instructions
- PICA SICA
- P
- PKG design ACTY
- 14933
- SPI date
- 00000
Related items
Standardization
- Item standardization code
- 5
- Orig stdzn dec
- 9T
- Dt stdzn dec
- 26-NOV-1989
- NIIN status code
- 0
Cancelled and replaced NIINs
- FSC
- 5905
- Cancelled NIIN
- 5905-00-058-1191
- NIIN status code
- 7
- Effective date
- 02-JUL-2026
- DEMIL code
- A
Request a quote