Catalog item
Request a quoteRESISTOR,THERMAL
5905FSC
00NCB code
889-0221Item number
NIIN 00-889-0221
- Unit price
- $9.49
- Unit of issue
- EA
- Source of supply
- SMS
- DEMIL code
- A
Identification
- Item name code
- 00309
- PINC
- 0000309
- Criticality code
- X
- II
- 0
- DEMIL code
- A
- NIIN assigned
- 01-JAN-60
- Precious metals indicator
- U
- Hazardous material indicator
- N
- Schedule B export code
- 8533400080
- FedMall
- Y
Management
| Effective date | Major organizational entity | Acquisition advice code | Source of supply | Unit of issue | Unit of measure quantity | Unit price | Quantity per unit pack | Controlled inventory item code | Shelf-life code | Recoverability code | Management control | Net price | USC |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 01-OCT-2026 | DA | J | SMS | EA | 0.0000 | $9.49 | 1 | U | 0 | Z | Q2200X- | $0.00 | A |
| 01-OCT-2026 | DS | J | SMS | EA | 0.0000 | $9.49 | 1 | U | 0 | N | ------- | $0.00 | I |
Part numbers
- Part number
- 9RT1C5
- CAGE
- 24446GENERAL ELECTRIC COMPANY
- CAGE status
- A
- RNCC
- 3
- RNVC
- 2
- Document availability code
- E
- RNAAC
- TX
- RNFC
- 3
- RNSC
- D
Characteristics
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -13.7 TO 13.7 |
|---|---|
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -15.1 TO 15.1 |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -16.6 TO 16.6 |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -16.9 TO 16.9 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | THIRD RESISTANCE-TEMPERATURE POINT KILOHMS 1.0 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | NINTH RESISTANCE-TEMPERATURE POINT OHMS 3.4 |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -20.1 TO 20.1 |
| INCLOSURE TYPE | ENCAPSULATED |
| CUBIC MEASURE | CUBIC INCHES 0.034 |
| ZERO POWER RESISTANCE | OHMS 100.000 |
| ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP | -10.0 TO 10.0 |
| REFERENCE TEMP IN DEG CELSIUS | 25.0 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | SIXTH RESISTANCE-TEMPERATURE POINT OHMS 36.0 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | EIGHTH RESISTANCE-TEMPERATURE POINT OHMS 6.0 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | FIFTH RESISTANCE-TEMPERATURE POINT OHMS 56.0 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | FIRST RESISTANCE-TEMPERATURE POINT KILOHMS 9.5 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | FOURTH RESISTANCE-TEMPERATURE POINT OHMS 330.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | FIFTH RESISTANCE-TEMPERATURE POINT CELSIUS 37.8 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | FIRST RESISTANCE-TEMPERATURE POINT CELSIUS -55.0 |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -12.6 TO 12.6 |
| MAXIMUM OPERATING TEMP | CELSIUS 150.0 |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -14.2 TO 14.2 |
| POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS | 55.0 |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -17.8 TO 17.8 |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -18.9 TO 18.9 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | SEVENTH RESISTANCE-TEMPERATURE POINT CELSIUS 75.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | SIXTH RESISTANCE-TEMPERATURE POINT CELSIUS 50.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | TENTH RESISTANCE-TEMPERATURE POINT CELSIUS 150.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | THIRD RESISTANCE-TEMPERATURE POINT CELSIUS -21.5 |
| SURFACE TREATMENT | TERMINAL SOLDER |
| STYLE DESIGNATOR | |
| TERMINAL TYPE AND QUANTITY | TAB, SOLDER LUG 1 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | TENTH RESISTANCE-TEMPERATURE POINT OHMS 1.8 |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| OVERALL LENGTH | INCHES NOMINAL 1.188 |
| TERMINAL LENGTH | INCHES NOMINAL 0.438 |
| OVERALL HEIGHT | INCHES MAXIMUM 0.275 |
| OVERALL WIDTH | INCHES NOMINAL 0.750 |
| BODY OUTSIDE DIAMETER | INCHES NOMINAL 0.750 |
| WASHER THICKNESS | INCHES NOMINAL 0.046 |
| AMBIENT TEMP AT FULL RATED POWER | CELSIUS 25.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | EIGHTH RESISTANCE-TEMPERATURE POINT CELSIUS 104.4 |
| THERMAL TIME CONSTANT IN SECONDS | 400.0 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | SECOND RESISTANCE-TEMPERATURE POINT KILOHMS 3.4 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | FOURTH RESISTANCE-TEMPERATURE POINT CELSIUS 0.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | NINTH RESISTANCE-TEMPERATURE POINT CELSIUS 125.0 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | SEVENTH RESISTANCE-TEMPERATURE POINT OHMS 15.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | SECOND RESISTANCE-TEMPERATURE POINT CELSIUS -40.0 |
MOE rules
| MOE rule | MOE CD | AMC | AMSC | Date assigned | IMC | IMCA | PICA | PICA LOA | SICA | SICA LOA | Auth collab | Supp collab | Fmr MOE rl |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| A918 | DA | 3 | L | 01-JUL-05 | Z | CD | GX | 01 | CD | 5D | CD GX | CL | A196 |
| VJ01 | VJ | 01-DEC-18 | VJ | 81 | VJ |
Service data
Army
- Matcat 1
- Q
- Matcat 2
- 2
- Matcat 3
- 2
- Matcat 4 5
- 00
- ARC
- X
Freight
- ACTY CD
- XX
- NMFC
- 061700
- NMFC sub
- Z
- Uniform freight class
- 34580
- Less than truckload
- W
- Water commodity code
- 72D
- Type of cargo code
- Z
- Special handling code
- 9
- Air dimension code
- A
- Air commodity code
- HZ
- NMF description
- ELEC APPLIANCES/INSTRUMENTS NOI
Packaging
Unit and preservation
- PICA SICA
- P
- PKG cat
- 69F0
- Unpackaged weight
- 0.0000
- Unpackaged width
- 0.000
- Unpackaged length
- 0.000
- Unpackaged height
- 0.000
- TOS
- A
- Intermediate container qty
- AAAQuantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
- Method of preservation
- 41Watervaporproof bag, heat sealed
- Clng drying
- 1Any suitable process that is not injurious to the item.
- Pres mat
- 00No requirement
- Wrap mat
- FAMIL-P-130, laminated and creped wrapping paper
- Cush dun
- 00No requirement
- THK
- 0Not applicable
- Unit cont
- D3PPP-B-566, PPP-B-676, or ASTM D5118/D5118M, folding, setup or fiberboard box.
- PKG data source
- P
Unit pack
- PICA SICA
- P
- SPC MKG
- ZZSpecial requirements
- Inter cont
- D1PPP-B-566 or PPP-B-676, folding or setup box.
- Lvl A
- QPacking shall be accomplished in accordance with table C.II for the packing level specified.
- Lvl b
- QPacking shall be accomplished in accordance with table C-II for the packing level specified.
- Unit pack weight
- 0.1000
- UP SZ MAXB
- 0.00000
- UP SZ MAXL
- 0.00000
- UP SZ MAXH
- 0.00000
- Unit pack cube
- 0.0090
- OPI
- MAll packaging data is mandatory for compliance and no substitutions are permitted.
- Supplemental instructions
- UNIT PACKAGE MARKING REQUI
Packaging instructions
- PICA SICA
- P
- PKG design ACTY
- 14933
- SPI date
- 00000
Related items
Standardization
- Item standardization code
- 6
- Orig stdzn dec
- TX
- Dt stdzn dec
- 21-MAR-1968
- NIIN status code
- 0
Request a quote
Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.