Catalog item

RESISTOR,THERMAL

5905FSC
00NCB code
907-2033Item number
NIIN 00-907-2033
Request a quote
Unit price
$335.72
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
00309
PINC
0000309
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
01-JAN-60
Precious metals indicator
U
Hazardous material indicator
N
ESD/EMI code
B
Schedule B export code
8533400080

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DAZSMSEA0.0000$335.721U0ZQ24TVX-$0.00A
01-OCT-2026DFZSMSEA0.0000$335.721U0NSF9EH-N$0.00F
01-OCT-2026DMJSMSEA0.0000$335.721U0Z15B2---$0.00M
01-OCT-2026DNZSMSEA0.0000$335.721U09B-----$0.00N
01-OCT-2026DSZSMSEA0.0000$335.721U0N-------$0.00I
01-OCT-2026GPZSMSEA0.0000$335.721U0-------$0.00C

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSCSADC
M2-103J1L9U5
MEASUREMENT SPECIALTIES, INC.
AC16ZZ3D9F
481040-803B150
RAYTHEON COMPANY DBA RAYTHEON CO
A321TX
481040-8049956
RAYTHEON COMPANY DIV CORP
A591TX3B
481040-8054X10
RAYTHEON COMPANY
A525ZZ
051138-001165597
THALES USA, INC. DIV AIR MOBILITY SOLUTIONS ("AMS")
A52548
73018880249
BAE SYSTEMS INFORMATION AND ELECTRONIC SYSTEMS INTEGRATION INC.
A721TX3D
M2-103J83186
MEAS US LLC DBA MEASUREMENT SPECIALTIES DIV TEMPERATURE PRODUCTS GROUP
R596TX3B
TM1/4 103J96214
RAYTHEON COMPANY DBA RAYTHEON
A59ETXB
TM1/4 103J01295
TEXAS INSTRUMENTS INCORPORATED
A59ETXB
TM1/4,10K,10%01295
TEXAS INSTRUMENTS INCORPORATED
AC16ZZAC
TM1/4-103J12969
MICRO USPD INC
A526TX
TM1/4 103J12969
MICRO USPD INC
A525TX
MM1-4 103J14552
MICROSEMI CORPORATION
R596TX3B

Characteristics

ZERO POWER RESISTANCE AT SPECIFIED TEMPTHIRD RESISTANCE-TEMPERATURE POINT KILOHMS 5.4
ZERO POWER RESISTANCE AT SPECIFIED TEMPTENTH RESISTANCE-TEMPERATURE POINT KILOHMS 22.3
ZERO POWER RESISTANCE AT SPECIFIED TEMPSIXTH RESISTANCE-TEMPERATURE POINT KILOHMS 12.0
ZERO POWER RESISTANCE AT SPECIFIED TEMPSEVENTH RESISTANCE-TEMPERATURE POINT KILOHMS 14.1
ZERO POWER RESISTANCE AT SPECIFIED TEMPSECOND RESISTANCE-TEMPERATURE POINT KILOHMS 4.7
ZERO POWER RESISTANCE AT SPECIFIED TEMPFOURTH RESISTANCE-TEMPERATURE POINT KILOHMS 6.6
ZERO POWER RESISTANCE AT SPECIFIED TEMPNINTH RESISTANCE-TEMPERATURE POINT KILOHMS 20.0
ZERO POWER RESISTANCE AT SPECIFIED TEMPFIRST RESISTANCE-TEMPERATURE POINT KILOHMS 4.4
RELIABILITY INDICATORNOT ESTABLISHED
TERMINAL LENGTHINCHES NOMINAL 1.500
ZERO POWER RESISTANCE AT SPECIFIED TEMPEIGHTH RESISTANCE-TEMPERATURE POINT KILOHMS 16.7
ZERO POWER RESISTANCE AT SPECIFIED TEMPFIFTH RESISTANCE-TEMPERATURE POINT KILOHMS 8.2
ZERO POWER RESISTANCEKILOHMS 10.000
ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP-5.0 TO 5.0
STYLE DESIGNATOR
TERMINAL TYPE AND QUANTITYWIRE LEAD 2
MAXIMUM OPERATING TEMPCELSIUS 150.0
THERMAL TIME CONSTANT IN SECONDS54.0
POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS5.0
ZERO POWER TEMP COEFFICIENT OF RESISTANCE IN PERCENT PER DEG CELSIUS0.70
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWEREIGHTH RESISTANCE-TEMPERATURE POINT CELSIUS 100.0
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWERTHIRD RESISTANCE-TEMPERATURE POINT CELSIUS -50.0
INCLOSURE TYPEENCAPSULATED
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWERSECOND RESISTANCE-TEMPERATURE POINT CELSIUS -65.0
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWERFIFTH RESISTANCE-TEMPERATURE POINT CELSIUS 0.0
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWERFIRST RESISTANCE-TEMPERATURE POINT CELSIUS -75.0
BODY LENGTHINCHES NOMINAL 0.585
BODY OUTSIDE DIAMETERINCHES NOMINAL 0.200
TERMINAL DIAMETERINCHES NOMINAL 0.025
MAXIMUM POWER DISSIPATION RATINGMILLIWATTS 250.00
AMBIENT TEMP AT FULL RATED POWERCELSIUS 100.0
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-10.1 TO 10.1
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-5.3 TO 5.3
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-6.6 TO 6.6
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-6.7 TO 6.7
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-7.2 TO 7.2
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-7.4 TO 7.4
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-8.0 TO 8.0
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-8.3 TO 8.3
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-8.5 TO 8.5
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-9.2 TO 9.2
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWERNINTH RESISTANCE-TEMPERATURE POINT CELSIUS 125.0
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWERTENTH RESISTANCE-TEMPERATURE POINT CELSIUS 150.0
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWERSEVENTH RESISTANCE-TEMPERATURE POINT CELSIUS 75.0
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWERSIXTH RESISTANCE-TEMPERATURE POINT CELSIUS 50.0
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWERFOURTH RESISTANCE-TEMPERATURE POINT CELSIUS -25.0

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabSupp collabFmr MOE rl
YA01YA01-DEC-01YA81YA
YB01YB01-APR-91YB81YB
ZC01ZC01-APR-91ZC81ZC
ZF01ZF01-APR-91ZF81ZF
ZH01ZH01-APR-91ZH81ZH
ZJ01ZJ01-MAR-25ZJ81ZJ
ZT01ZT01-APR-91ZT81ZT
ZU01ZU01-APR-91ZU81ZU
ZW01ZW01-NOV-98ZW81ZW
A918DA1G01-APR-06ZCDGX01CD5DCD GXA196
C911GP1G01-APR-06GX01XG5DXG GXC007
FXGXDF1G01-APR-06ZSXGX01SX5DGX TUFXTX
MC49DM1G01-APR-06ZPAGX01PA5DGX PAMC13
N9BNDN1G01-APR-06ZGHGX01GH5DGXHD KENIND

Service data

Army

Matcat 1
Q
Matcat 2
2
Matcat 3
4
Matcat 4 5
TV
ARC
X

Navy

COG
9B

Air Force

Fund
SF
Budget
9
MMAC
EH
PVC
N
ERRC
N

Marine Corps

SAC
1
CEC
5
MEC
B2

Freight

ACTY CD
XX
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
72D
Type of cargo code
3
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
A
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
41
Watervaporproof bag, heat sealed
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
FA
MIL-P-130, laminated and creped wrapping paper
Cush dun
00
No requirement
THK
0
Not applicable
Unit cont
D3
PPP-B-566, PPP-B-676, or ASTM D5118/D5118M, folding, setup or fiberboard box.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
ZZ
Special requirements
Inter cont
DO
Any suitable fiber box included in this table may be used (see J.4.9.1).
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
0.1000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0030
OPI
M
All packaging data is mandatory for compliance and no substitutions are permitted.
Supplemental instructions
UNIT PACKAGE MARKING REQUI

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Related NSNItem standardization codeOrig stdzn decDt stdzn decNIIN status code
5905-00-961-16213TX07-MAR-19740
1TX07-SEP-19710
3TX07-MAR-19740

Cancelled and replaced NIINs

FSC
5905
Cancelled NIIN
5905-00-455-1937
NIIN status code
7
Effective date
02-JUL-2026
DEMIL code
A

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.