Catalog item

RESISTOR,THERMAL

5905FSC
00NCB code
940-8177Item number
NIIN 00-940-8177
Request a quote
Unit price
$139.94
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
00309
PINC
0000309
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
04-FEB-66
Precious metals indicator
U
Hazardous material indicator
N
ESD/EMI code
B
Schedule B export code
8533400080

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DAJSMSEA0.0000$139.941U0ZQ2200X-$0.00A
01-OCT-2026DFJSMSEA0.0000$139.941U0NSF9EH-N$0.00F
01-OCT-2026DMJSMSEA0.0000$139.941U0Z15B2B--$0.00M
01-OCT-2026DNJSMSEA0.0000$139.941U09B-----$0.00N
01-OCT-2026DSJSMSEA0.0000$139.941U0N-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
714-1754-00095105
ROCKWELL COLLINS, INC. DIV COLLINS AEROSPACE - MISSION SYSTEMS
A32AZZ
0325F5-03810646
CESIWID INC
R595ZZB
997F3810646
CESIWID INC
R594TA3B

Characteristics

STYLE DESIGNATOR
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWEREIGHTH RESISTANCE-TEMPERATURE POINT CELSIUS 100.0
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWERFIFTH RESISTANCE-TEMPERATURE POINT CELSIUS 40.0
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-12.1 TO 12.1
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWERSIXTH RESISTANCE-TEMPERATURE POINT CELSIUS 60.0
ZERO POWER RESISTANCE AT SPECIFIED TEMPFIFTH RESISTANCE-TEMPERATURE POINT OHMS 39.0
POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS6.0
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-10.2 TO 10.2
REFERENCE TEMP IN DEG CELSIUS25.0
SURFACE TREATMENTTERMINAL SOLDER
BODY LENGTHINCHES NOMINAL 0.328
ZERO POWER RESISTANCE AT SPECIFIED TEMPSEVENTH RESISTANCE-TEMPERATURE POINT OHMS 21.0
ZERO POWER RESISTANCE AT SPECIFIED TEMPSIXTH RESISTANCE-TEMPERATURE POINT OHMS 27.5
ZERO POWER RESISTANCE AT SPECIFIED TEMPTENTH RESISTANCE-TEMPERATURE POINT OHMS 10.0
ZERO POWER RESISTANCE AT SPECIFIED TEMPFOURTH RESISTANCE-TEMPERATURE POINT OHMS 55.5
ZERO POWER RESISTANCE AT SPECIFIED TEMPNINTH RESISTANCE-TEMPERATURE POINT OHMS 12.5
ZERO POWER RESISTANCE AT SPECIFIED TEMPSECOND RESISTANCE-TEMPERATURE POINT OHMS 130.0
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWERSECOND RESISTANCE-TEMPERATURE POINT CELSIUS -20.0
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWERSEVENTH RESISTANCE-TEMPERATURE POINT CELSIUS 80.0
ZERO POWER RESISTANCE AT SPECIFIED TEMPEIGHTH RESISTANCE-TEMPERATURE POINT OHMS 15.5
ZERO POWER RESISTANCE AT SPECIFIED TEMPTHIRD RESISTANCE-TEMPERATURE POINT OHMS 85.5
ZERO POWER RESISTANCE AT SPECIFIED TEMPFIRST RESISTANCE-TEMPERATURE POINT OHMS 225.0
TERMINAL TYPE AND QUANTITYWIRE LEAD 2
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWERTENTH RESISTANCE-TEMPERATURE POINT CELSIUS 140.0
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWERTHIRD RESISTANCE-TEMPERATURE POINT CELSIUS 0.0
BODY OUTSIDE DIAMETERINCHES NOMINAL 0.141
TERMINAL DIAMETERINCHES NOMINAL 0.020
AMBIENT TEMP AT FULL RATED POWERCELSIUS 25.0
ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP-10.0 TO 10.0
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-13.3 TO 13.3
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-14.9 TO 14.9
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-15.1 TO 15.1
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-16.2 TO 16.2
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-17.3 TO 17.3
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-18.6 TO 18.6
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-19.1 TO 19.1
INCLOSURE TYPEENCAPSULATED
CUBIC MEASURECUBIC INCHES 0.004
ZERO POWER RESISTANCEOHMS 50.000
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWERFIRST RESISTANCE-TEMPERATURE POINT CELSIUS -40.0
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWERFOURTH RESISTANCE-TEMPERATURE POINT CELSIUS 20.0
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWERNINTH RESISTANCE-TEMPERATURE POINT CELSIUS 120.0
MAXIMUM OPERATING TEMPCELSIUS 150.0
THERMAL TIME CONSTANT IN SECONDS10.0
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-17.8 TO 17.8
RELIABILITY INDICATORNOT ESTABLISHED
TERMINAL LENGTHINCHES NOMINAL 1.500

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabSupp collabFmr MOE rl
WB01WB01-FEB-05WB81WB
YA01YA01-NOV-08YA81YA
ZF01ZF01-APR-91ZF81ZF
ZG01ZG01-APR-91ZG81ZG
ZJ01ZJ01-APR-25ZJ81ZJ
ZP01ZP01-APR-91ZP81ZP
ZU01ZU01-APR-08ZU81ZU
ZW01ZW01-NOV-05ZW81ZW
A918DA3Z01-APR-06ZCDGX01CD5DCD GXCLA196
FXGXDF3Z01-APR-06ZSXGX01SX5DGX TUFXTX
MC49DM3Z01-APR-06ZPAGX01PA5DGX PAMC13
N9BNDN3Z01-APR-06ZGHGX01GH5DGXHD KEN9ND

Service data

Army

Matcat 1
Q
Matcat 2
2
Matcat 3
2
Matcat 4 5
00
ARC
X

Navy

COG
9B

Air Force

Fund
SF
Budget
9
MMAC
EH
PVC
N
ERRC
N

Marine Corps

SAC
1
CEC
5
MEC
B2
MIC
B

Freight

ACTY CD
SG
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
72D
Type of cargo code
3
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
41
Watervaporproof bag, heat sealed
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
00
No requirement
Cush dun
00
No requirement
THK
0
Not applicable
Unit cont
D3
PPP-B-566, PPP-B-676, or ASTM D5118/D5118M, folding, setup or fiberboard box.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
ZZ
Special requirements
Inter cont
D3
PPP-B-566, PPP-B-676, or ASTM D5118/D5118M, folding, setup or fiberboard box.
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
0.0000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0030
OPI
M
All packaging data is mandatory for compliance and no substitutions are permitted.
Supplemental instructions
UNIT PACKAGE MARKING REQUI

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
6
Orig stdzn dec
TX
Dt stdzn dec
21-MAR-1968
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.