Catalog item

RESISTOR,THERMAL

5905FSC
00NCB code
954-3646Item number
NIIN 00-954-3646
Request a quote
Unit price
$301.38
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
00309
PINC
0000309
Criticality code
X
II
0
DEMIL code
A
NIIN assigned
01-JAN-63
Precious metals indicator
U
Hazardous material indicator
N
ESD/EMI code
B
Schedule B export code
8533400080

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DAJSMSEA0.0000$301.381U0ZQ2200X-$0.00A
01-OCT-2026DFJSMSEA0.0000$301.381U0NSF9EH-N$0.00F
01-OCT-2026DNJSMSEA0.0000$301.381U09B-----$0.00N
01-OCT-2026DSJSMSEA0.0000$301.381U0N-------$0.00I
01-OCT-2026GPJSMSEA0.0000$301.381U0-------$0.00C

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSCRNJC
41541-025-7K4547
SIEMENS AIR TRAFFIC MANAGEMENT
H592ZK3B
TM1-401295
TEXAS INSTRUMENTS INCORPORATED
A39XXX3D1
DS250-3760HMS10PCT15454
RTIE HOLDINGS LLC
A526TX
DS250-376OHMPORM10PCT15454
RTIE HOLDINGS LLC
A523TX

Characteristics

RELIABILITY INDICATORNOT ESTABLISHED
TERMINAL LENGTHINCHES NOMINAL 1.500
ZERO POWER RESISTANCE AT SPECIFIED TEMPEIGHTH RESISTANCE-TEMPERATURE POINT OHMS 612.9
BODY OUTSIDE DIAMETERINCHES NOMINAL 0.200
TERMINAL DIAMETERINCHES NOMINAL 0.025
MAXIMUM POWER DISSIPATION RATINGMILLIWATTS 0.25
AMBIENT TEMP AT FULL RATED POWERCELSIUS 25.0
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-12.1 TO 12.1
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-12.8 TO 12.8
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-14.3 TO 14.3
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-15.0 TO 15.0
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-16.1 TO 16.1
ZERO POWER RESISTANCE AT SPECIFIED TEMPNINTH RESISTANCE-TEMPERATURE POINT OHMS 733.2
ZERO POWER RESISTANCE AT SPECIFIED TEMPSECOND RESISTANCE-TEMPERATURE POINT OHMS 184.2
ZERO POWER RESISTANCE AT SPECIFIED TEMPFIFTH RESISTANCE-TEMPERATURE POINT OHMS 312.1
ZERO POWER RESISTANCE AT SPECIFIED TEMPFIRST RESISTANCE-TEMPERATURE POINT OHMS 169.2
BODY LENGTHINCHES NOMINAL 0.585
ZERO POWER RESISTANCE AT SPECIFIED TEMPSEVENTH RESISTANCE-TEMPERATURE POINT OHMS 526.4
ZERO POWER RESISTANCE AT SPECIFIED TEMPSIXTH RESISTANCE-TEMPERATURE POINT OHMS 443.7
ZERO POWER RESISTANCE AT SPECIFIED TEMPTENTH RESISTANCE-TEMPERATURE POINT OHMS 827.2
ZERO POWER RESISTANCE AT SPECIFIED TEMPTHIRD RESISTANCE-TEMPERATURE POINT OHMS 210.6
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-10.3 TO 10.3
ZERO POWER RESISTANCE AT SPECIFIED TEMPFOURTH RESISTANCE-TEMPERATURE POINT OHMS 255.7
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWERSIXTH RESISTANCE-TEMPERATURE POINT CELSIUS 50.0
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWERTENTH RESISTANCE-TEMPERATURE POINT CELSIUS 150.0
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWERTHIRD RESISTANCE-TEMPERATURE POINT CELSIUS -50.0
ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP-10.0 TO 10.0
REFERENCE TEMP IN DEG CELSIUS25.0
SURFACE TREATMENTTERMINAL SOLDER
STYLE DESIGNATOR
TERMINAL TYPE AND QUANTITYWIRE LEAD 2
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-22.8 TO 22.8
INCLOSURE TYPEENCAPSULATED
CUBIC MEASURECUBIC INCHES 0.014
ZERO POWER RESISTANCEOHMS 376.000
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-20.0 TO 20.0
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWERNINTH RESISTANCE-TEMPERATURE POINT CELSIUS 125.0
MAXIMUM OPERATING TEMPCELSIUS 150.0
THERMAL TIME CONSTANT IN SECONDS54.0
POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS5.0
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWEREIGHTH RESISTANCE-TEMPERATURE POINT CELSIUS 100.0
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWERFIFTH RESISTANCE-TEMPERATURE POINT CELSIUS 0.0
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWERFIRST RESISTANCE-TEMPERATURE POINT CELSIUS -75.0
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWERFOURTH RESISTANCE-TEMPERATURE POINT CELSIUS -25.0
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-18.5 TO 18.5
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWERSECOND RESISTANCE-TEMPERATURE POINT CELSIUS -65.0
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWERSEVENTH RESISTANCE-TEMPERATURE POINT CELSIUS 75.0
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-16.2 TO 16.2

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabSupp collabFmr MOE rl
YA01YA01-DEC-01YA81YA
YB01YB01-APR-91YB81YB
YY01YY01-FEB-15YY81YY
ZC01ZC01-APR-91ZC81ZC
ZH01ZH01-APR-91ZH81ZH
ZR01ZR01-JUL-97ZR81ZR
ZU01ZU01-APR-91ZU81ZU
ZW01ZW01-NOV-98ZW81ZW
A918DA3C01-APR-06ZCDGX01CD5DCD GXCLA196
C911GP3C01-APR-06GX01XG5DXG GXC007
FXGXDF3C01-APR-06ZSXGX01SX5DGX TUFXTX
N9BNDN3C01-APR-06ZGHGX01GH5DGXJB HD GTNIND

Service data

Army

Matcat 1
Q
Matcat 2
2
Matcat 3
2
Matcat 4 5
00
ARC
X

Navy

COG
9B

Air Force

Fund
SF
Budget
9
MMAC
EH
PVC
N
ERRC
N

Freight

ACTY CD
XX
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
72D
Type of cargo code
3
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
41
Watervaporproof bag, heat sealed
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
00
No requirement
Cush dun
00
No requirement
THK
0
Not applicable
Unit cont
D3
PPP-B-566, PPP-B-676, or ASTM D5118/D5118M, folding, setup or fiberboard box.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
ZZ
Special requirements
Inter cont
D1
PPP-B-566 or PPP-B-676, folding or setup box.
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
0.0000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0000
OPI
M
All packaging data is mandatory for compliance and no substitutions are permitted.
Supplemental instructions
UNIT PACKAGE MARKING REQUI

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
6
Orig stdzn dec
TX
Dt stdzn dec
24-NOV-1968
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.