Catalog item
Request a quoteRESISTOR,THERMAL
5905FSC
00NCB code
955-9882Item number
NIIN 00-955-9882
- Unit price
- $17.18
- Unit of issue
- EA
- Source of supply
- SMS
- DEMIL code
- A
Identification
- Item name code
- 00309
- PINC
- 0000309
- Criticality code
- X
- II
- 0
- DEMIL code
- A
- NIIN assigned
- 01-JAN-62
- Precious metals indicator
- U
- Hazardous material indicator
- N
- Schedule B export code
- 8533400080
Management
- Effective date
- 01-OCT-2026
- Major organizational entity
- DS
- Acquisition advice code
- Y
- Source of supply
- SMS
- Unit of issue
- EA
- Unit of measure quantity
- 0.0000
- Unit price
- $17.18
- Quantity per unit pack
- 1
- Controlled inventory item code
- U
- Shelf-life code
- 0
- Management control
- -------
- Net price
- $0.00
- USC
- I
Part numbers
Characteristics
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | FIFTH RESISTANCE-TEMPERATURE POINT OHMS 58.5 |
|---|---|
| TERMINAL LENGTH | INCHES MINIMUM 1.000 |
| BODY LENGTH | INCHES MINIMUM 0.390 AND INCHES MAXIMUM 0.420 |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -12.8 TO 12.8 |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -14.3 TO 14.3 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | SECOND RESISTANCE-TEMPERATURE POINT CELSIUS -65.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | THIRD RESISTANCE-TEMPERATURE POINT CELSIUS -50.0 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | EIGHTH RESISTANCE-TEMPERATURE POINT OHMS 104.0 |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | SEVENTH RESISTANCE-TEMPERATURE POINT CELSIUS 75.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | SIXTH RESISTANCE-TEMPERATURE POINT CELSIUS 50.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | TENTH RESISTANCE-TEMPERATURE POINT CELSIUS 150.0 |
| ZERO POWER RESISTANCE | OHMS 68.000 |
| ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP | -10.0 TO 10.0 |
| STYLE DESIGNATOR | |
| TERMINAL TYPE AND QUANTITY | WIRE LEAD 2 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | NINTH RESISTANCE-TEMPERATURE POINT OHMS 120.4 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | SECOND RESISTANCE-TEMPERATURE POINT OHMS 39.4 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | SEVENTH RESISTANCE-TEMPERATURE POINT OHMS 90.6 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | SIXTH RESISTANCE-TEMPERATURE POINT OHMS 78.2 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | TENTH RESISTANCE-TEMPERATURE POINT OHMS 135.8 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | THIRD RESISTANCE-TEMPERATURE POINT OHMS 42.8 |
| MAXIMUM POWER DISSIPATION RATING | MILLIWATTS 125.00 |
| AMBIENT TEMP AT FULL RATED POWER | CELSIUS 100.0 |
| MAXIMUM OPERATING TEMP | CELSIUS 125.0 |
| THERMAL TIME CONSTANT IN SECONDS | 35.0 |
| POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS | 2.5 |
| ZERO POWER TEMP COEFFICIENT OF RESISTANCE IN PERCENT PER DEG CELSIUS | 0.70 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | EIGHTH RESISTANCE-TEMPERATURE POINT CELSIUS 100.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | FIFTH RESISTANCE-TEMPERATURE POINT CELSIUS 0.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | FIRST RESISTANCE-TEMPERATURE POINT CELSIUS -75.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | FOURTH RESISTANCE-TEMPERATURE POINT CELSIUS -25.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | NINTH RESISTANCE-TEMPERATURE POINT CELSIUS 125.0 |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -18.5 TO 18.5 |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -20.0 TO 20.0 |
| INCLOSURE TYPE | ENCAPSULATED |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -14.6 TO 14.6 |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -15.0 TO 15.0 |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -16.1 TO 16.1 |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -16.2 TO 16.2 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | FOURTH RESISTANCE-TEMPERATURE POINT OHMS 50.3 |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -10.3 TO 10.3 |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -12.1 TO 12.1 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | FIRST RESISTANCE-TEMPERATURE POINT OHMS 36.7 |
| TERMINAL DIAMETER | INCHES NOMINAL 0.025 |
| BODY OUTSIDE DIAMETER | INCHES MINIMUM 0.125 AND INCHES MAXIMUM 0.155 |
MOE rules
| MOE rule | MOE CD | AMC | AMSC | Date assigned | PICA | PICA LOA | Auth collab | Supp collab | Fmr MOE rl |
|---|---|---|---|---|---|---|---|---|---|
| ZC01 | ZC | 01-APR-91 | ZC | 81 | ZC | ||||
| ZH01 | ZH | 01-APR-91 | ZH | 81 | ZH | ||||
| DGX1 | DS | 3 | C | 01-JUL-05 | GX | 01 | GX | TX | DTX1 |
Freight
- ACTY CD
- XX
- NMFC
- 061700
- NMFC sub
- Z
- Uniform freight class
- 34580
- Less than truckload
- W
- Water commodity code
- 658
- Type of cargo code
- Z
- Special handling code
- 9
- Air dimension code
- A
- Air commodity code
- HZ
- NMF description
- ELEC APPLIANCES/INSTRUMENTS NOI
Packaging
Unit and preservation
- PICA SICA
- P
- PKG cat
- 69F0
- Unpackaged weight
- 0.0000
- Unpackaged width
- 0.000
- Unpackaged length
- 0.000
- Unpackaged height
- 0.000
- Intermediate container qty
- AAAQuantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
- Method of preservation
- 41Watervaporproof bag, heat sealed
- Clng drying
- 1Any suitable process that is not injurious to the item.
- Pres mat
- 00No requirement
- Wrap mat
- 00No requirement
- Cush dun
- 00No requirement
- THK
- 0Not applicable
- Unit cont
- D3PPP-B-566, PPP-B-676, or ASTM D5118/D5118M, folding, setup or fiberboard box.
- PKG data source
- P
Unit pack
- PICA SICA
- P
- SPC MKG
- ZZSpecial requirements
- Inter cont
- D1PPP-B-566 or PPP-B-676, folding or setup box.
- Lvl A
- QPacking shall be accomplished in accordance with table C.II for the packing level specified.
- Lvl b
- QPacking shall be accomplished in accordance with table C-II for the packing level specified.
- Unit pack weight
- 0.0000
- UP SZ MAXB
- 0.00000
- UP SZ MAXL
- 0.00000
- UP SZ MAXH
- 0.00000
- Unit pack cube
- 0.0000
- OPI
- MAll packaging data is mandatory for compliance and no substitutions are permitted.
- Supplemental instructions
- UNIT PACKAGE MARKING REQUI
Packaging instructions
- PICA SICA
- P
- PKG design ACTY
- 14933
- SPI date
- 00000
Related items
Standardization
- Item standardization code
- 6
- Orig stdzn dec
- TX
- Dt stdzn dec
- 21-MAR-1968
- NIIN status code
- 0
Request a quote
Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.