Catalog item
Request a quoteRESISTOR,THERMAL
5905FSC
00NCB code
993-9984Item number
NIIN 00-993-9984
- Unit price
- $31.06
- Unit of issue
- EA
- Source of supply
- SMS
- DEMIL code
- A
Identification
- Item name code
- 00309
- PINC
- 0000309
- Criticality code
- X
- II
- 0
- DEMIL code
- A
- NIIN assigned
- 01-JAN-62
- Precious metals indicator
- U
- Hazardous material indicator
- N
- Schedule B export code
- 8533400080
Management
| Effective date | Major organizational entity | Acquisition advice code | Source of supply | Unit of issue | Unit of measure quantity | Unit price | Quantity per unit pack | Controlled inventory item code | Shelf-life code | Management control | Net price | USC |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 01-OCT-2026 | DN | J | SMS | EA | 0.0000 | $31.06 | 1 | U | 0 | 9B----- | $0.00 | N |
| 01-OCT-2026 | DS | J | SMS | EA | 0.0000 | $31.06 | 1 | U | 0 | ------- | $0.00 | I |
Part numbers
Characteristics
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | EIGHTH RESISTANCE-TEMPERATURE POINT CELSIUS 90.0 |
|---|---|
| MAXIMUM OPERATING TEMP | CELSIUS 150.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | NINTH RESISTANCE-TEMPERATURE POINT CELSIUS 104.4 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | SECOND RESISTANCE-TEMPERATURE POINT CELSIUS -40.0 |
| THERMAL TIME CONSTANT IN SECONDS | 15.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | SIXTH RESISTANCE-TEMPERATURE POINT CELSIUS 55.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | THIRD RESISTANCE-TEMPERATURE POINT CELSIUS -21.5 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | EIGHTH RESISTANCE-TEMPERATURE POINT KILOHMS 4.64 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | FIFTH RESISTANCE-TEMPERATURE POINT KILOHMS 36.8 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | FIRST RESISTANCE-TEMPERATURE POINT MEGOHMS 11.54 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | FOURTH RESISTANCE-TEMPERATURE POINT KILOHMS 67.8 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | NINTH RESISTANCE-TEMPERATURE POINT KILOHMS 2.88 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | SECOND RESISTANCE-TEMPERATURE POINT MEGOHMS 3.51 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | SEVENTH RESISTANCE-TEMPERATURE POINT KILOHMS 7.92 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | SIXTH RESISTANCE-TEMPERATURE POINT KILOHMS 17.36 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | THIRD RESISTANCE-TEMPERATURE POINT KILOHMS 975.0 |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -10.0 TO 10.0 |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -13.0 TO 13.0 |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -15.0 TO 15.0 |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -18.0 TO 18.0 |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -20.0 TO 20.0 |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -27.0 TO 27.0 |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -30.0 TO 30.0 |
| INCLOSURE TYPE | ENCAPSULATED |
| ZERO POWER RESISTANCE | KILOHMS 36.800 |
| ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP | -10.0 TO 10.0 |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| SURFACE TREATMENT | TERMINAL SOLDER |
| STYLE DESIGNATOR | |
| TERMINAL TYPE AND QUANTITY | WIRE LEAD 2 |
| ZERO POWER TEMP COEFFICIENT OF RESISTANCE IN PERCENT PER DEG CELSIUS | 11.80 |
| TERMINAL LENGTH | INCHES NOMINAL 1.500 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | FOURTH RESISTANCE-TEMPERATURE POINT CELSIUS 25.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | FIRST RESISTANCE-TEMPERATURE POINT CELSIUS -55.0 |
| AMBIENT TEMP AT FULL RATED POWER | CELSIUS 37.8 |
| BODY LENGTH | INCHES NOMINAL 0.270 |
| BODY OUTSIDE DIAMETER | INCHES NOMINAL 0.130 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | SEVENTH RESISTANCE-TEMPERATURE POINT CELSIUS 75.0 |
| REFERENCE TEMP IN DEG CELSIUS | 37.8 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | FIFTH RESISTANCE-TEMPERATURE POINT CELSIUS 37.8 |
| TERMINAL DIAMETER | INCHES NOMINAL 0.025 |
MOE rules
| MOE rule | MOE CD | AMC | AMSC | Date assigned | IMC | IMCA | PICA | PICA LOA | SICA | SICA LOA | Auth collab | Supp collab | Fmr MOE rl |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| YB01 | YB | 01-APR-91 | YB | 81 | YB | ||||||||
| ZH01 | ZH | 01-AUG-95 | ZH | 81 | ZH | ||||||||
| ZU01 | ZU | 01-JUL-05 | ZU | 81 | ZU | ||||||||
| N9BN | DN | 3 | L | 01-JUL-05 | Z | GH | GX | 01 | GH | 5D | GX | GT KE | NIND |
Service data
Navy
- COG
- 9B
Freight
- ACTY CD
- XX
- NMFC
- 061700
- NMFC sub
- Z
- Uniform freight class
- 34580
- Less than truckload
- W
- Water commodity code
- 658
- Type of cargo code
- Z
- Special handling code
- 9
- Air dimension code
- A
- Air commodity code
- HZ
- NMF description
- ELEC APPLIANCES/INSTRUMENTS NOI
Packaging
Unit and preservation
- PICA SICA
- P
- PKG cat
- 69F0
- Unpackaged weight
- 0.0000
- Unpackaged width
- 0.000
- Unpackaged length
- 0.000
- Unpackaged height
- 0.000
- Intermediate container qty
- AAAQuantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
- Method of preservation
- 41Watervaporproof bag, heat sealed
- Clng drying
- 1Any suitable process that is not injurious to the item.
- Pres mat
- 00No requirement
- Wrap mat
- 00No requirement
- Cush dun
- 00No requirement
- THK
- 0Not applicable
- Unit cont
- D3PPP-B-566, PPP-B-676, or ASTM D5118/D5118M, folding, setup or fiberboard box.
- PKG data source
- P
Unit pack
- PICA SICA
- P
- SPC MKG
- ZZSpecial requirements
- Inter cont
- D1PPP-B-566 or PPP-B-676, folding or setup box.
- Lvl A
- QPacking shall be accomplished in accordance with table C.II for the packing level specified.
- Lvl b
- QPacking shall be accomplished in accordance with table C-II for the packing level specified.
- Unit pack weight
- 0.0000
- UP SZ MAXB
- 0.00000
- UP SZ MAXL
- 0.00000
- UP SZ MAXH
- 0.00000
- Unit pack cube
- 0.0000
- OPI
- MAll packaging data is mandatory for compliance and no substitutions are permitted.
- Supplemental instructions
- UNIT PACKAGE MARKING REQUI
Packaging instructions
- PICA SICA
- P
- PKG design ACTY
- 14933
- SPI date
- 00000
Related items
Standardization
- Item standardization code
- 6
- Orig stdzn dec
- TX
- Dt stdzn dec
- 21-MAR-1968
- NIIN status code
- 0
Request a quote
Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.