Catalog item

RESISTOR,FIXED,FILM

5905FSC
01NCB code
005-9581Item number
NIIN 01-005-9581
Request a quote
Unit price
$3.25
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
05311
PINC
0005311
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
13-JUL-75
Precious metals indicator
U
Hazardous material indicator
N
ESD/EMI code
B
Schedule B export code
8533100042

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DAJSMSEA0.0000$3.251U0ZQ2200X-$0.00A
01-OCT-2026DNJSMSEA0.0000$3.251U09B-----$0.00N
01-OCT-2026DSJSMSEA0.0000$3.251U0N-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSCSADC
RNC65K1374FS81349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A223TX1D
MIL-PRF-55182/581349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A41EZZ
MIL-R-55182/581349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A593TX1B
RN65D1374F81349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
AC16ZZAC

Characteristics

TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS-100.0 TO 100.0
ELECTRICAL RESISTANCEMEGOHMS 1.370
RESISTANCE TOLERANCE IN PERCENT-1.000 TO 1.000
AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER175.0
TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS-55.0 TO 175.0
RELIABILITY INDICATORESTABLISHED
RELIABILITY FAILURE RATE LEVEL IN PERCENT0.001
TERMINAL LENGTHINCHES NOMINAL 1.500
BODY DIAMETERINCHES NOMINAL 0.188
BODY LENGTHINCHES NOMINAL 0.625
POWER DISSIPATION RATING IN WATTSFREE AIR 0.250
AMBIENT TEMP AT FULL RATED POWERCELSIUS 125.0
INCLOSURE TYPEENCAPSULATED
TERMINAL TYPEWIRE LEAD
STYLE DESIGNATOR
TEST DATA DOCUMENTSPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 81349--ILR55182

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabSupp collabFmr MOE rl
ZC01ZC01-APR-91ZC81ZC
ZR01ZR01-DEC-07ZR81ZR
ZW01ZW01-DEC-95ZW81ZW
A918DA1T01-APR-06ZCDGX01CD5DCD GXA196
N9BNDN1T01-APR-06ZKEGX01GH5DGXGT KEN9ND

Service data

Army

Matcat 1
Q
Matcat 2
2
Matcat 3
2
Matcat 4 5
00
ARC
X

Navy

COG
9B

Freight

ACTY CD
TX
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
72D
Type of cargo code
3
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
GX
Preserve by Method 41 using an approved ESD control program (see 5.2.4.1.1) as follows: Items subject to damage by...
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
00
No requirement
Cush dun
00
No requirement
THK
0
Not applicable
Unit cont
ZZ
Special requirement – See specific instructions or drawings provided.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
ZZ
Special requirements
Inter cont
D3
PPP-B-566, PPP-B-676, or ASTM D5118/D5118M, folding, setup or fiberboard box.
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
0.1000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0020
OPI
M
All packaging data is mandatory for compliance and no substitutions are permitted.
Supplemental instructions
UNIT PACKAGE MARKING REQUI

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
81050

Full packaging code breakdown

Related items

Standardization

Related NSNItem standardization codeOrig stdzn decDt stdzn decNIIN status code
5905-00-702-4705ETX31-JUL-19750
BTX31-JUL-19750
ETX31-JUL-19750

Cancelled and replaced NIINs

FSC
5905
Cancelled NIIN
5905-00-578-9058
NIIN status code
5
Effective date
01-JUL-2026
DEMIL code
A

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.