Catalog item
Request a quoteRESISTOR NETWORK,FIXED,WIRE WOUN
5905FSC
01NCB code
008-5287Item number
NIIN 01-008-5287
- Unit price
- $872.70
- Unit of issue
- EA
- Source of supply
- SMS
- DEMIL code
- A
Identification
- Item name code
- 32069
- PINC
- 0032069
- Criticality code
- X
- II
- 0
- DEMIL code
- A
- DEMIL integrity code
- 1
- NIIN assigned
- 25-AUG-75
- Precious metals indicator
- U
- Hazardous material indicator
- N
- ESD/EMI code
- B
- Schedule B export code
- 8533100057
- FedMall
- Y
Management
| Effective date | Major organizational entity | Acquisition advice code | Source of supply | Unit of issue | Unit of measure quantity | Unit price | Quantity per unit pack | Controlled inventory item code | Shelf-life code | Management control | Net price | USC |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 01-OCT-2026 | DN | J | SMS | EA | 0.0000 | $872.70 | 1 | U | 0 | 9B----- | $0.00 | N |
| 01-OCT-2026 | DS | J | SMS | EA | 0.0000 | $872.70 | 1 | U | 0 | ------- | $0.00 | I |
Part numbers
| Part number | CAGE | CAGE status | RNCC | RNVC | Document availability code | RNAAC | RNFC | RNSC | SADC |
|---|---|---|---|---|---|---|---|---|---|
| SP1134 | 53655 AVOX SYSTEMS INC DBA AVOX SYSTEMS INC | A | E | 8 | 5 | TX | |||
| SP1134-2 | 53655 AVOX SYSTEMS INC DBA AVOX SYSTEMS INC | A | 5 | 9 | 5 | TX | B | ||
| TS-3968-1 | 54485 MICROSEMI CORP.- MASSACHUSETTS DBA MICROSEMI LAWRENCE | A | 5 | 1 | 5 | TX | |||
| NAS1379P2N | 80205 NATIONAL AEROSPACE STANDARDS COMMITTEE AEROSPACE INDUSTRIES ASSOCIATION OF AMERICA INC NOT FOR RFQ OR SOLICITATION USE | A | C | 1 | 5 | ZZ | AC | ||
| 956082-1 | 82577 RAYTHEON COMPANY DBA RAYTHEON | A | E | 8 | 1 | TX | |||
| 956082-2 | 82577 RAYTHEON COMPANY DBA RAYTHEON | A | 3 | 2 | 1 | TX | 1 | D | |
| 2429-2 | 05347 ULTRONIX INC | H | 5 | 9 | 5 | ZZ | B | ||
| 2429 | 05347 ULTRONIX INC | H | 5 | 9 | 5 | TX | B | ||
| HRN1007 | 07284 HAMBY CORPORATION | A | 5 | 9 | 5 | TX | B | ||
| SP1134-2 | 14193 CAL-R INC | H | 5 | 9 | 5 | TX | B |
Characteristics
| TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS | -25.0 TO 25.0 |
|---|---|
| ELECTRICAL RESISTANCE | SEVENTH INTERMEDIATE RESISTANCE VALUE OHMS 256.000 |
| ELECTRICAL RESISTANCE | FIFTH INTERMEDIATE RESISTANCE VALUE OHMS 64.000 |
| ELECTRICAL RESISTANCE | FOURTH INTERMEDIATE RESISTANCE VALUE OHMS 32.000 |
| ELECTRICAL RESISTANCE | LOWEST RESISTANCE VALUE OHMS 2.000 |
| ELECTRICAL RESISTANCE | SECOND INTERMEDIATE RESISTANCE VALUE OHMS 8.000 |
| ELECTRICAL RESISTANCE | THIRD INTERMEDIATE RESISTANCE VALUE OHMS 16.000 |
| ELECTRICAL RESISTANCE | FIRST INTERMEDIATE RESISTANCE VALUE OHMS 4.000 |
| ELECTRICAL RESISTANCE | NINTH INTERMEDIATE RESISTANCE VALUE KILOHMS 1.024 |
| ELECTRICAL RESISTANCE | EIGHTH INTERMEDIATE RESISTANCE VALUE OHMS 512.000 |
| ELECTRICAL RESISTANCE | SIXTH INTERMEDIATE RESISTANCE VALUE OHMS 128.000 |
| ELECTRICAL RESISTANCE | HIGHEST RESISTANCE VALUE KILOHMS 2.048 |
| RESISTANCE TOLERANCE IN PERCENT | -1.000 TO 1.000 |
| RESISTANCE TOLERANCE IN PERCENT | -0.500 TO 0.500 |
| RESISTANCE TOLERANCE IN PERCENT | -2.500 TO 2.500 |
| RESISTANCE TOLERANCE IN PERCENT | -0.100 TO 0.100 |
| RESISTANCE TOLERANCE IN PERCENT | -5.000 TO 5.000 |
| AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER | 125.0 |
| AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER | 150.0 |
| TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS | -55.0 TO 125.0 |
| INCLOSURE METHOD | ENCAPSULATED |
| TERMINAL QUANTITY | 12 |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| TERMINAL LENGTH | INCHES NOMINAL 0.100 |
| BODY LENGTH | INCHES NOMINAL 0.600 |
| BODY WIDTH | INCHES NOMINAL 0.400 |
| BODY HEIGHT | INCHES NOMINAL 0.185 |
| SCHEMATIC DIAGRAM DESIGNATOR | |
| POWER DISSIPATION RATING IN WATTS | TOTAL NETWORK 0.500 |
| IDENTICAL VALUE RESISTOR QUANTITY | 1 |
| TERMINAL TYPE | PIN |
| STYLE DESIGNATOR |
MOE rules
| MOE rule | MOE CD | AMC | AMSC | Date assigned | IMC | IMCA | PICA | PICA LOA | SICA | SICA LOA | Auth collab | Supp collab | Fmr MOE rl |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| VP01 | VP | 01-JAN-25 | VP | 81 | VP | ||||||||
| N9BN | DN | 1 | C | 01-APR-06 | Z | KE | GX | 01 | GH | 5D | GX | GT KE | N9ND |
Service data
Navy
- COG
- 9B
Freight
- ACTY CD
- TX
- NMFC
- 061700
- NMFC sub
- Z
- Uniform freight class
- 34580
- Less than truckload
- W
- Water commodity code
- 72D
- Type of cargo code
- 3
- Special handling code
- 9
- Air dimension code
- A
- Air commodity code
- HZ
- NMF description
- ELEC APPLIANCES/INSTRUMENTS NOI
Packaging
Unit and preservation
- PICA SICA
- P
- PKG cat
- 69F0
- Unpackaged weight
- 0.0000
- Unpackaged width
- 0.000
- Unpackaged length
- 0.000
- Unpackaged height
- 0.000
- Intermediate container qty
- AAAQuantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
- Method of preservation
- GXPreserve by Method 41 using an approved ESD control program (see 5.2.4.1.1) as follows: Items subject to damage by...
- Clng drying
- 1Any suitable process that is not injurious to the item.
- Pres mat
- 00No requirement
- Wrap mat
- ZZSpecial requirements – see specific instructions or drawings provided
- Cush dun
- ZZSpecial requirements.
- THK
- C3/4 inch thick
- Unit cont
- ZZSpecial requirement – See specific instructions or drawings provided.
- PKG data source
- P
Unit pack
- PICA SICA
- P
- SPC MKG
- ZZSpecial requirements
- Inter cont
- D3PPP-B-566, PPP-B-676, or ASTM D5118/D5118M, folding, setup or fiberboard box.
- Lvl A
- QPacking shall be accomplished in accordance with table C.II for the packing level specified.
- Lvl b
- QPacking shall be accomplished in accordance with table C-II for the packing level specified.
- Unit pack weight
- 0.1000
- UP SZ MAXB
- 0.00000
- UP SZ MAXL
- 0.00000
- UP SZ MAXH
- 0.00000
- Unit pack cube
- 0.0030
- OPI
- MAll packaging data is mandatory for compliance and no substitutions are permitted.
- Supplemental instructions
- UNIT PACKAGE MARKING REQUI
Packaging instructions
- PICA SICA
- P
- PKG design ACTY
- 14933
- SPI date
- 00000
Related items
Standardization
- Item standardization code
- 5
- Orig stdzn dec
- TX
- Dt stdzn dec
- 01-MAY-2001
- NIIN status code
- 0
Cancelled and replaced NIINs
- FSC
- 5905
- Cancelled NIIN
- 5905-00-004-5903
- NIIN status code
- 5
- Effective date
- 02-JUL-2026
- DEMIL code
- A
Request a quote
Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.