Catalog item

RESISTOR,THERMAL

5905FSC
01NCB code
024-4273Item number
NIIN 01-024-4273
Request a quote
Unit price
$14.32
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
00309
PINC
0000309
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
11-JUL-76
Precious metals indicator
U
Hazardous material indicator
N
ESD/EMI code
B
Schedule B export code
8533400080

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DFJSMSEA0.0000$14.321U0NSF9EH-N$0.00F
01-OCT-2026DNJSMSEA0.0000$14.321U09B-----$0.00N
01-OCT-2026DSJSMSEA0.0000$14.321U0N-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
192-503QETA0115801
HONEYWELL INTERNATIONAL INC. DBA HONEYWELL DIV SENSING & CONTROL
A325TX
UUT45J115801
HONEYWELL INTERNATIONAL INC. DBA HONEYWELL DIV SENSING & CONTROL
A593TX1B
UUT45J1-50K15801
HONEYWELL INTERNATIONAL INC. DBA HONEYWELL DIV SENSING & CONTROL
A594TX1B

Characteristics

RELIABILITY INDICATORNOT ESTABLISHED
TERMINAL LENGTHINCHES NOMINAL 3.000
BODY LENGTHINCHES MAXIMUM 0.095
BODY OUTSIDE DIAMETERINCHES MAXIMUM 0.095
TERMINAL DIAMETERINCHES NOMINAL 0.008
AMBIENT TEMP AT FULL RATED POWERCELSIUS 25.0
MAXIMUM OPERATING TEMPCELSIUS 150.0
THERMAL TIME CONSTANT IN SECONDS10.0
POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS1.0
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWERSECOND RESISTANCE-TEMPERATURE POINT CELSIUS -15.0
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWERSEVENTH RESISTANCE-TEMPERATURE POINT CELSIUS 150.0
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWERFIFTH RESISTANCE-TEMPERATURE POINT CELSIUS 75.0
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWERFOURTH RESISTANCE-TEMPERATURE POINT CELSIUS 40.0
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWERSIXTH RESISTANCE-TEMPERATURE POINT CELSIUS 100.0
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWERFIRST RESISTANCE-TEMPERATURE POINT CELSIUS -40.0
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWERTHIRD RESISTANCE-TEMPERATURE POINT CELSIUS 0.0
ZERO POWER RESISTANCE AT SPECIFIED TEMPSIXTH RESISTANCE-TEMPERATURE POINT KILOHMS 2.8
ZERO POWER RESISTANCE AT SPECIFIED TEMPTHIRD RESISTANCE-TEMPERATURE POINT KILOHMS 175.0
ZERO POWER RESISTANCE AT SPECIFIED TEMPFOURTH RESISTANCE-TEMPERATURE POINT KILOHMS 25.5
ZERO POWER RESISTANCE AT SPECIFIED TEMPSEVENTH RESISTANCE-TEMPERATURE POINT OHMS 666.0
ZERO POWER RESISTANCE AT SPECIFIED TEMPFIFTH RESISTANCE-TEMPERATURE POINT KILOHMS 6.5
ZERO POWER RESISTANCE AT SPECIFIED TEMPSECOND RESISTANCE-TEMPERATURE POINT KILOHMS 409.0
ZERO POWER RESISTANCE AT SPECIFIED TEMPFIRST RESISTANCE-TEMPERATURE POINT MEGOHMS 2.0
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-15.0 TO 15.0
INCLOSURE TYPEENCAPSULATED
ZERO POWER RESISTANCEKILOHMS 50.000
ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP-1.0 TO 1.0
STYLE DESIGNATOR
TERMINAL TYPE AND QUANTITYWIRE LEAD 2

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabSupp collabFmr MOE rl
ZC01ZC01-APR-91ZC81ZC
ZG01ZG01-APR-91ZG81ZG
ZK01ZK01-APR-91ZK81ZK
ZR01ZR01-APR-91ZR81ZR
FXGXDF3L01-APR-06ZSXGX01SX5DGX TUFXTX
N9BNDN3L01-APR-06ZKEGX01GH5DGXKE GT HDN9ND

Service data

Navy

COG
9B

Air Force

Fund
SF
Budget
9
MMAC
EH
PVC
N
ERRC
N

Freight

ACTY CD
TX
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
72D
Type of cargo code
3
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
ZZ
Special requirements apply that are not represented by the code symbols; details are provided with the acquisition...
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
ZZ
Special requirement – See specific instructions or drawings provided
Wrap mat
ZZ
Special requirements – see specific instructions or drawings provided
Cush dun
ZZ
Special requirements.
THK
C
3/4 inch thick
Unit cont
ZZ
Special requirement – See specific instructions or drawings provided.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
ZZ
Special requirements
Inter cont
ZZ
Special requirement – See specific instructions or drawings provided.
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
0.1000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0030
OPI
M
All packaging data is mandatory for compliance and no substitutions are permitted.
Supplemental instructions
PRESERVATION AND PACKAGING

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
5
Orig stdzn dec
97
Dt stdzn dec
11-JUL-1976
NIIN status code
0

Cancelled and replaced NIINs

FSC
5905
Cancelled NIIN
5905-01-076-5804
NIIN status code
7
Effective date
02-JUL-2026
DEMIL code
A

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.