Catalog item

RESISTOR,FIXED,FILM

5905FSC
01NCB code
034-2576Item number
NIIN 01-034-2576
Request a quote
Unit price
$153.76
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
05311
PINC
0005311
Criticality code
H
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
22-JAN-77
Precious metals indicator
U
Hazardous material indicator
N
ESD/EMI code
B
Schedule B export code
8533100042

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DFJSMSEA0.0000$153.761U0NSF9EH-N$0.00F
01-OCT-2026DNJSMSEA0.0000$153.761U09B-----$0.00N
01-OCT-2026DSJSMSEA0.0000$153.761U0N-------$0.00I
01-OCT-2026GPJSMSEA0.0000$153.761U0-------$0.00C

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSCSADC
MIL-PRF-55182/781349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A41EZZ
RNC50H10R0BM81349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
AC16ZZAC
RNC50H10R0BS81349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A22ETX1D
MIL-R-55182/781349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A59ETX1B

Characteristics

TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS-50.0 TO 50.0
ELECTRICAL RESISTANCEOHMS 10.000
RESISTANCE TOLERANCE IN PERCENT-0.100 TO 0.100
AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER175.0
TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS-55.0 TO 175.0
MIL-STD-1276 WIRE LEAD TYPE DESIGNATORC
RELIABILITY INDICATORESTABLISHED
RELIABILITY FAILURE RATE LEVEL IN PERCENT0.001
TERMINAL LENGTHINCHES MINIMUM 0.984 AND INCHES MAXIMUM 1.516
BODY DIAMETERINCHES MINIMUM 0.050 AND INCHES MAXIMUM 0.080
BODY LENGTHINCHES MINIMUM 0.160 AND INCHES MAXIMUM 0.200
POWER DISSIPATION RATING IN WATTSFREE AIR 0.200
AMBIENT TEMP AT FULL RATED POWERCELSIUS 125.0
INCLOSURE TYPEENCAPSULATED
TERMINAL TYPEWIRE LEAD
SPECIAL FEATURESNUCLEAR HARDNESS CRITICAL ITEMS
NUCLEAR HARDNESS CRITICAL FEATUREHARDENED
UNPACKAGED UNIT WEIGHTGRAMS 0.11
STYLE DESIGNATOR
TEST DATA DOCUMENTSPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 81349--IL-R-55182
SPECIFICATION/STANDARD DATAGOVERNMENT SPECIFICATION 81349--IL-R-55182 TO 7

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabSupp collabFmr MOE rl
YA01YA01-OCT-00YA81YA
ZA01ZA01-AUG-09ZA81ZA
ZR01ZR01-NOV-98ZR81ZR
C911GP1T01-APR-06GX01XG5DXG GXC007
FXGXDF1T01-APR-06ZSXGX01SX5DGX TUFXTX
N9BNDN1T01-APR-06ZHDGX01GH5DGXKEN9ND

Service data

Navy

COG
9B

Air Force

Fund
SF
Budget
9
MMAC
EH
PVC
N
ERRC
N

Freight

ACTY CD
ZQ
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
72D
Type of cargo code
3
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
GX
Preserve by Method 41 using an approved ESD control program (see 5.2.4.1.1) as follows: Items subject to damage by...
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
00
No requirement
Cush dun
00
No requirement
THK
0
Not applicable
Unit cont
ZZ
Special requirement – See specific instructions or drawings provided.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
ZZ
Special requirements
Inter cont
D3
PPP-B-566, PPP-B-676, or ASTM D5118/D5118M, folding, setup or fiberboard box.
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
0.1000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0010
OPI
M
All packaging data is mandatory for compliance and no substitutions are permitted.
Supplemental instructions
UNIT PACKAGE MARKING REQUI

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
81226

Full packaging code breakdown

Related items

Standardization

Item standardization code
2
Orig stdzn dec
TX
Dt stdzn dec
29-DEC-1977
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.