Catalog item

RESISTOR,FIXED,FILM

5905FSC
01NCB code
046-0484Item number
NIIN 01-046-0484
Request a quote
Unit price
$21.89
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
05311
PINC
0005311
Criticality code
X
II
0
DEMIL code
A
NIIN assigned
11-AUG-77
Precious metals indicator
A
Hazardous material indicator
N
ESD/EMI code
B
Schedule B export code
8533100042

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DFZSMSEA0.0000$21.891U0NSF9EH-N$0.00F
01-OCT-2026DNZSMSEA0.0000$21.891U09B-----$0.00N
01-OCT-2026DSZSMSEA0.0000$21.891U0N-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSCSADC
MK132-2701-5PCT19647
CADDOCK ELECTRONICS INC.
AC16ZZAC
MK132-270119647
CADDOCK ELECTRONICS INC.
A52548
MK132-2701F19647
CADDOCK ELECTRONICS INC.
A52ETX
MK132-2701J19647
CADDOCK ELECTRONICS INC.
AE8ETX4D
581170-323B150
RAYTHEON COMPANY DBA RAYTHEON CO
A52ATX
2903002-3249956
RAYTHEON COMPANY DIV CORP
AC16ZZAC
581170-3249956
RAYTHEON COMPANY DIV CORP
A59ATX4B
581170-3254X10
RAYTHEON COMPANY
A525ZZ
2903002-13510001
NAVAIR AND NAVSEA MANAGED ORIGINAL DESIGN ACTIVITY DWG NOT MATERIAL/PARTS SUPPLIER
A32ATX
2903002-3210001
NAVAIR AND NAVSEA MANAGED ORIGINAL DESIGN ACTIVITY DWG NOT MATERIAL/PARTS SUPPLIER
AE81TX4D

Characteristics

TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS-50.0 TO 50.0
ELECTRICAL RESISTANCEKILOHMS 2.700
RESISTANCE TOLERANCE IN PERCENT-1.000 TO 1.000
AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER175.0
TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS-15.0 TO 105.0
RELIABILITY INDICATORNOT ESTABLISHED
TERMINAL LENGTHINCHES MINIMUM 1.500 AND INCHES MAXIMUM 1.625
BODY LENGTHINCHES MINIMUM 0.280 AND INCHES MAXIMUM 0.300
BODY WIDTHINCHES MINIMUM 0.280 AND INCHES MAXIMUM 0.300
BODY HEIGHTINCHES MINIMUM 0.090 AND INCHES MAXIMUM 0.100
POWER DISSIPATION RATING IN WATTSFREE AIR 0.750
AMBIENT TEMP AT FULL RATED POWERCELSIUS 125.0
INCLOSURE TYPEENCAPSULATED
TERMINAL TYPEWIRE LEAD
UNPACKAGED UNIT WEIGHTGRAMS 1.3
STYLE DESIGNATOR
TEST DATA DOCUMENTDRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) 10001-2903002

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabSupp collabFmr MOE rl
WP01WP01-JAN-09WP81WP
YB01YB01-MAY-97YB81YB
ZG01ZG01-APR-91ZG81ZG
ZJ01ZJ01-APR-25ZJ81ZJ
ZW01ZW01-NOV-98ZW81ZW
BGX1GE1L01-NOV-05GX01485DGX 48BTX1
FXGXDF1L01-NOV-05ZSXGX01SX5DGX TUFXTX
N9BNDN1L01-NOV-05ZHDGX01GH5DGXHDN9ND

Service data

Navy

COG
9B

Air Force

Fund
SF
Budget
9
MMAC
EH
PVC
N
ERRC
N

Freight

ACTY CD
TX
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
72D
Type of cargo code
3
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
ZZ
Special requirements apply that are not represented by the code symbols; details are provided with the acquisition...
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
ZZ
Special requirement – See specific instructions or drawings provided
Wrap mat
ZZ
Special requirements – see specific instructions or drawings provided
Cush dun
ZZ
Special requirements.
THK
C
3/4 inch thick
Unit cont
ZZ
Special requirement – See specific instructions or drawings provided.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
ZZ
Special requirements
Inter cont
ZZ
Special requirement – See specific instructions or drawings provided.
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
0.1000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0010
OPI
M
All packaging data is mandatory for compliance and no substitutions are permitted.
Supplemental instructions
PRESERVATION AND PACKAGING

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
5
Orig stdzn dec
9Z
Dt stdzn dec
01-JAN-2009
NIIN status code
0

Cancelled and replaced NIINs

FSC
5905
Cancelled NIIN
5905-01-079-8898
NIIN status code
5
Effective date
02-JUL-2026
DEMIL code
A

Request a quote