Catalog item

RESISTOR,THERMAL

5905FSC
01NCB code
071-7341Item number
NIIN 01-071-7341
Request a quote
Unit price
$113.25
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
00309
PINC
0000309
Criticality code
X
II
0
DEMIL code
A
NIIN assigned
14-FEB-79
Precious metals indicator
U
Hazardous material indicator
N
ESD/EMI code
A
Schedule B export code
8533400080

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DFZSMSEA0.0000$113.251U0NSF9---N$0.00F
01-OCT-2026DNJSMSEA0.0000$113.250U09B-----$0.00N
01-OCT-2026DSZSMSEA0.0000$113.251U0-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
RTH42ES510K81349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
AE849Z1D
MIL-PRF-23648/1981349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A41EZZ
MIL-T-23648/1981349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A5949Z1B
RTH42ES470K81349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A2249Z1D

Characteristics

RELIABILITY INDICATORNOT ESTABLISHED
TERMINAL LENGTHINCHES MINIMUM 1.200
BODY LENGTHINCHES NOMINAL 0.285
BODY OUTSIDE DIAMETERINCHES NOMINAL 0.100
TERMINAL DIAMETERINCHES NOMINAL 0.020
MAXIMUM POWER DISSIPATION RATINGWATTS 0.25
AMBIENT TEMP AT FULL RATED POWERCELSIUS 25.0
MAXIMUM OPERATING TEMPCELSIUS 125.0
THERMAL TIME CONSTANT IN SECONDS60.0
POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS2.5
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWERFIFTH RESISTANCE-TEMPERATURE POINT CELSIUS 100.0
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWERSIXTH RESISTANCE-TEMPERATURE POINT CELSIUS 125.0
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWERFIRST RESISTANCE-TEMPERATURE POINT CELSIUS -55.0
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWERSECOND RESISTANCE-TEMPERATURE POINT CELSIUS -15.0
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWERTHIRD RESISTANCE-TEMPERATURE POINT CELSIUS 50.0
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWERFOURTH RESISTANCE-TEMPERATURE POINT CELSIUS 75.0
ZERO POWER RESISTANCE AT SPECIFIED TEMPFIRST RESISTANCE-TEMPERATURE POINT OHMS 28.9
ZERO POWER RESISTANCE AT SPECIFIED TEMPSIXTH RESISTANCE-TEMPERATURE POINT OHMS 82.2
ZERO POWER RESISTANCE AT SPECIFIED TEMPFIFTH RESISTANCE-TEMPERATURE POINT OHMS 72.6
ZERO POWER RESISTANCE AT SPECIFIED TEMPTHIRD RESISTANCE-TEMPERATURE POINT OHMS 54.5
ZERO POWER RESISTANCE AT SPECIFIED TEMPFOURTH RESISTANCE-TEMPERATURE POINT OHMS 63.4
ZERO POWER RESISTANCE AT SPECIFIED TEMPSECOND RESISTANCE-TEMPERATURE POINT OHMS 37.1
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-14.0 TO 14.0
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-12.0 TO 12.0
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-17.0 TO 17.0
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-20.0 TO 20.0
INCLOSURE TYPEHERMETICALLY SEALED
ZERO POWER RESISTANCEOHMS 47.000
ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP-10.0 TO 10.0
REFERENCE TEMP IN DEG CELSIUS25.0
STYLE DESIGNATOR
TEST DATA DOCUMENTSPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 81349--IL-T-23648 TO 19
TERMINAL TYPE AND QUANTITYWIRE LEAD 2

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabSupp collab
ZC01ZC01-APR-91ZC81ZC
ZR01ZR01-DEC-07ZR81ZR
FXGXDF2T01-SEP-18ZSXGX01SX5DGX TU
N9BNDN2T01-APR-19ZGHGX01GH5DGXGT HD KE

Management phrases

Major organizational entityUSCPhrase codePhraseOrder of useQuantity per assembly
DSIDOD I&S FAMILY MASTER NSN: 5905010717341ABA0
DSI7SUBSTITUTE FOR 5905-01-271-8106AAA0

Service data

Navy

COG
9B

Air Force

Fund
SF
Budget
9
PVC
N
ERRC
N

Freight

ACTY CD
ZG
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Less than carload
P
Water commodity code
658
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICA
P
PKG cat
27A0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
Intermediate container qty
100
100 unit packs per intermediate container
Method of preservation
41
Watervaporproof bag, heat sealed
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
00
No requirement
Cush dun
NA
PPP-C-795, closed cell plastic cushioning; or A-A-3129, open cell plastic cushioning; or PPP-C-1797, polypropylene...
THK
A
1/4 inch thick
Unit cont
BS
MIL-DTL-117, Type I, Class E, Style 1, heavy duty, watervaporproof, greaseproof, opaque bag.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
ZZ
Special requirements
Inter cont
E5
ASTM D5118/D5118M, fiberboard box.
Lvl A
E
Packing shall be accomplished to meet the performance test requirements of ASTM D4169, Distribution Cycle 18,...
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
0.0000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0000
OPI
M
All packaging data is mandatory for compliance and no substitutions are permitted.
Supplemental instructions
UNIT PACKAGE MARKING REQUI

Packaging instructions

PICA SICA
P
PKG design ACTY
14153
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Related NSNItem standardization codeOrig stdzn decDt stdzn decNIIN status code
5905-01-271-81063TX18-APR-20190
1TX25-SEP-20180
3TX18-APR-20190

Cancelled and replaced NIINs

FSC
5905
Cancelled NIIN
5905-01-071-7342
NIIN status code
5
Effective date
22-JUL-2026
DEMIL code
A

Request a quote