Catalog item

RESISTOR,FIXED,FILM

5905FSC
01NCB code
103-4686Item number
NIIN 01-103-4686
Request a quote
Unit price
$3.15
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
05311
PINC
0005311
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
13-NOV-80
Precious metals indicator
A
ADP equipment code
0
Hazardous material indicator
N
ESD/EMI code
B
Schedule B export code
8533100042

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DFJSMSEA0.0000$3.151U0NSF9---N$0.00F
01-OCT-2026DNJSMSEA0.0000$3.151U09B-----$0.00N
01-OCT-2026DSJSMSEA0.0000$3.151U0N-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSCSADC
16757165-48328009
SYPRIS ELECTRONICS, LLC DIV SYPRIS ELECTRONICS, LLC - COLORADO FIELD SERVICES
AC16ZZAC
RNC55K7153FS81349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A223TX4D
MIL-R-55182/181349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A593TX4B
RNR55K7153FS81349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
AC16ZZAC
RN55D7153FJ81349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
AC16ZZAC
MIL-PRF-55182/181349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A41EZZ

Characteristics

TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS-100.0 TO 100.0
ELECTRICAL RESISTANCEKILOHMS 715.000
RESISTANCE TOLERANCE IN PERCENT-1.000 TO 1.000
AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER175.0
TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS-55.0 TO 175.0
RELIABILITY INDICATORESTABLISHED
RELIABILITY FAILURE RATE LEVEL IN PERCENT0.001
TERMINAL LENGTHINCHES NOMINAL 1.500
BODY DIAMETERINCHES NOMINAL 0.109
BODY LENGTHINCHES NOMINAL 0.250
POWER DISSIPATION RATING IN WATTSFREE AIR 0.100
AMBIENT TEMP AT FULL RATED POWERCELSIUS 125.0
INCLOSURE TYPEENCAPSULATED
TERMINAL TYPEWIRE LEAD
STYLE DESIGNATOR
TEST DATA DOCUMENTSPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 81349--IL-R-55182
SPECIFICATION/STANDARD DATAGOVERNMENT SPECIFICATION 81349--IL-R-55182 TO 1

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabSupp collabFmr MOE rl
WP01WP01-DEC-03WP81WP
YA01YA01-OCT-00YA81YA
YB01YB01-MAY-97YB81YB
ZC01ZC01-APR-91ZC81ZC
ZW01ZW01-NOV-98ZW81ZW
FXGXDF1T01-APR-06ZSXGX01SX5DGX TUFXTX
N9BNDN1T01-APR-06ZHDGX01GH5DGXHX HD GTN9ND

Service data

Navy

COG
9B

Air Force

Fund
SF
Budget
9
PVC
N
ERRC
N

Freight

ACTY CD
TX
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
72D
Type of cargo code
3
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
Intermediate container qty
100
100 unit packs per intermediate container
Method of preservation
GX
Preserve by Method 41 using an approved ESD control program (see 5.2.4.1.1) as follows: Items subject to damage by...
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
K3
MIL-PRF-81705, Type III, Class 1, transparent, electrostatic protective, static shielding, barrier material or...
Cush dun
00
No requirement
THK
0
Not applicable
Unit cont
B9
MIL-DTL-117, Type I, Class F, Style 1, heavy duty, watervaporproof, electrostatic protective, opaque bag.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
ZZ
Special requirements
Inter cont
E5
ASTM D5118/D5118M, fiberboard box.
Lvl A
E
Packing shall be accomplished to meet the performance test requirements of ASTM D4169, Distribution Cycle 18,...
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
0.1000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0030
OPI
M
All packaging data is mandatory for compliance and no substitutions are permitted.
Supplemental instructions
ESD AND PHYSICAL PROTECTIO

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
85134

Full packaging code breakdown

Related items

Standardization

Item standardization code
5
Orig stdzn dec
96
Dt stdzn dec
26-DEC-1995
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.