Catalog item

RESISTOR,THERMAL

5905FSC
01NCB code
125-0732Item number
NIIN 01-125-0732
Request a quote
Unit price
$12.09
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
00309
PINC
0000309
Criticality code
X
II
0
DEMIL code
A
NIIN assigned
21-JAN-82
Precious metals indicator
A
Hazardous material indicator
N
Schedule B export code
8533400080

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DAJSMSEA0.0000$12.091U0ZQ2200X-$0.00A
01-OCT-2026DNJSMSEA0.0000$12.091U09B-----$0.00N
01-OCT-2026DSJSMSEA0.0000$12.091U0N-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAAC
B0411H-02245586
PANGBORN LLC
A523TX
714-3234-18013499
ROCKWELL COLLINS, INC. DBA COLLINS AEROSPACE GOVERNMENT SYSTEMS DIV COLLINS AEROSPACE - GOVERNMENT SYSTEMS
A321TX

Characteristics

RELIABILITY INDICATORNOT ESTABLISHED
TERMINAL LENGTHINCHES MINIMUM 1.500
BODY OUTSIDE DIAMETERINCHES NOMINAL 0.100
BODY WIDTHINCHES NOMINAL 0.110
TERMINAL DIAMETERINCHES NOMINAL 0.013
AMBIENT TEMP AT FULL RATED POWERCELSIUS 25.0
MAXIMUM OPERATING TEMPCELSIUS 150.0
THERMAL TIME CONSTANT IN SECONDS13.0
POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS4.0
ZERO POWER TEMP COEFFICIENT OF RESISTANCE IN PERCENT PER DEG CELSIUSM3.40
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWERNINTH RESISTANCE-TEMPERATURE POINT CELSIUS 120.0
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWERTENTH RESISTANCE-TEMPERATURE POINT CELSIUS 140.0
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWEREIGHTH RESISTANCE-TEMPERATURE POINT CELSIUS 100.0
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWERTHIRD RESISTANCE-TEMPERATURE POINT CELSIUS 0.0
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWERFIFTH RESISTANCE-TEMPERATURE POINT CELSIUS 40.0
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWERFOURTH RESISTANCE-TEMPERATURE POINT CELSIUS 20.0
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWERSECOND RESISTANCE-TEMPERATURE POINT CELSIUS -20.0
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWERSIXTH RESISTANCE-TEMPERATURE POINT CELSIUS 60.0
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWERFIRST RESISTANCE-TEMPERATURE POINT CELSIUS -40.0
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWERSEVENTH RESISTANCE-TEMPERATURE POINT CELSIUS 80.0
ZERO POWER RESISTANCE AT SPECIFIED TEMPTENTH RESISTANCE-TEMPERATURE POINT OHMS 12.0
ZERO POWER RESISTANCE AT SPECIFIED TEMPEIGHTH RESISTANCE-TEMPERATURE POINT OHMS 28.0
ZERO POWER RESISTANCE AT SPECIFIED TEMPFIRST RESISTANCE-TEMPERATURE POINT KILOHMS 3.3
ZERO POWER RESISTANCE AT SPECIFIED TEMPNINTH RESISTANCE-TEMPERATURE POINT OHMS 18.0
ZERO POWER RESISTANCE AT SPECIFIED TEMPSEVENTH RESISTANCE-TEMPERATURE POINT OHMS 42.0
ZERO POWER RESISTANCE AT SPECIFIED TEMPTHIRD RESISTANCE-TEMPERATURE POINT OHMS 502.0
ZERO POWER RESISTANCE AT SPECIFIED TEMPFIFTH RESISTANCE-TEMPERATURE POINT OHMS 124.0
ZERO POWER RESISTANCE AT SPECIFIED TEMPSECOND RESISTANCE-TEMPERATURE POINT KILOHMS 1.2
ZERO POWER RESISTANCE AT SPECIFIED TEMPFOURTH RESISTANCE-TEMPERATURE POINT OHMS 260.0
ZERO POWER RESISTANCE AT SPECIFIED TEMPSIXTH RESISTANCE-TEMPERATURE POINT OHMS 70.0
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-13.1 TO 13.1
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-17.9 TO 17.9
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-18.6 TO 18.6
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-12.7 TO 12.7
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-14.2 TO 14.2
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-16.7 TO 16.7
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-19.6 TO 19.6
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-10.3 TO 10.3
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-16.2 TO 16.2
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-20.9 TO 20.9
INCLOSURE TYPEENCAPSULATED
CUBIC MEASURECUBIC INCHES 0.00073
ZERO POWER RESISTANCEOHMS 200.000
ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP-10.0 TO 10.0
REFERENCE TEMP IN DEG CELSIUS25.0
SURFACE TREATMENTTERMINAL SOLDER
STYLE DESIGNATOR
TERMINAL TYPE AND QUANTITYWIRE LEAD 2

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabSupp collabFmr MOE rl
YW01YW01-JUL-93YW81YW
ZC01ZC01-APR-91ZC81ZC
ZU01ZU01-JUL-05ZU81ZU
A918DA3L01-APR-06ZCDGX01CD5DCD GXCLA196
N9BNDN3L01-APR-06ZHDGX01GH5DGXGT HDN9ND

Service data

Army

Matcat 1
Q
Matcat 2
2
Matcat 3
2
Matcat 4 5
00
ARC
X

Navy

COG
9B

Freight

ACTY CD
TX
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
72D
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
ZZ
Special requirements apply that are not represented by the code symbols; details are provided with the acquisition...
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
ZZ
Special requirement – See specific instructions or drawings provided
Wrap mat
ZZ
Special requirements – see specific instructions or drawings provided
Cush dun
ZZ
Special requirements.
THK
C
3/4 inch thick
Unit cont
ZZ
Special requirement – See specific instructions or drawings provided.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
ZZ
Special requirements
Inter cont
ZZ
Special requirement – See specific instructions or drawings provided.
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
0.1000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0090
OPI
M
All packaging data is mandatory for compliance and no substitutions are permitted.
Supplemental instructions
UNIT PACKAGE MARKING REQUI

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
82232

Full packaging code breakdown

Related items

Standardization

Item standardization code
5
Orig stdzn dec
97
Dt stdzn dec
21-JAN-1982
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.