Catalog item

RESISTOR,VARIABLE,NONWIRE WOUND,

5905FSC
01NCB code
232-4691Item number
NIIN 01-232-4691
Request a quote
Unit price
$14.30
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
37405
PINC
0037405
Criticality code
X
II
0
DEMIL code
A
NIIN assigned
15-MAY-86
Precious metals indicator
A
Hazardous material indicator
N
Schedule B export code
8710000090

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DAJSMSEA0.0000$14.301U0ZQ2200X-$0.00A
01-OCT-2026DMZSMSEA0.0000$14.301U0Z15B2---$0.00M
01-OCT-2026DNJSMSEA0.0000$14.301U09B-----$0.00N
01-OCT-2026DSJSMSEA0.0000$14.301U0N-------$0.00I

Part numbers

Part number
013481
CAGE
31922
LEEDS AND NORTHRUP CO A UNIT OF GENERAL SIGNAL CORP
CAGE status
H
RNCC
3
RNVC
9
Document availability code
B
RNAAC
TX

Characteristics

SECTION QUANTITY1
BODY STYLE
RELIABILITY INDICATORNOT ESTABLISHED
OVERALL LENGTHINCHES NOMINAL 0.860
TERMINAL LENGTHINCHES MINIMUM 0.145
OVERALL HEIGHTINCHES MINIMUM 0.475
OVERALL WIDTHINCHES MAXIMUM 0.200
SHAFT DIAMETERINCHES MINIMUM 0.088 AND INCHES MAXIMUM 0.110
SHAFT LENGTHINCHES MINIMUM 0.045 AND INCHES MAXIMUM 0.110
BODY LENGTHINCHES NOMINAL 0.750
BODY WIDTHINCHES MINIMUM 0.150 AND INCHES MAXIMUM 0.200
BODY HEIGHTINCHES MINIMUM 0.300 AND INCHES MAXIMUM 0.375
SHAFT STYLE
ACTUATOR TYPESINGLE SHAFT
EFFECTIVE ELECTRICAL ROTATION IN DEG ANGULAR ROTATIONNOMINAL 7200.0
MAXIMUM STARTING TORQUEINCH-OUNCES 8.00
MAXIMUM RUNNING TORQUEINCH-OUNCES 8.00
CENTER TO CENTER DISTANCE BETWEEN TERMINALSINCHES NOMINAL 0.500
FRAGILITY FACTORMODERATELY RUGGED
MOUNTING METHODTERMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINAL ROWSINCHES NOMINAL 0.100
FEATURES PROVIDEDHUMIDITY PROOF
CUBIC MEASURECUBIC INCHES 0.056
ELECTRICAL RESISTANCE PER SECTIONKILOHMS SINGLE SECTION 100.0
ROTARY ACTUATOR TRAVEL IN ANGULAR DEGNOMINAL 7200.0
CENTER TO CENTER DISTANCE BETWEEN CENTER TERMINAL AND OUTSIDE TERMINALINCHES NOMINAL 0.200
AMBIENT TEMP IN DEG CELSIUS PER SECTION AT ZERO PERCENT RATED POWERSINGLE SECTION 125.0
TERMINAL LOCATIONLOWER ADJACENT SIDE TWO ROWS
TEMP COEFFICIENT OF RESISTANCE PER SECTION IN PPM PER DEG CELSIUSSINGLE SECTION -100.0 TO 100.0
POWER DISSIPATION RATING PER SECTION IN WATTSFREE AIR SINGLE SECTION 0.75
RESISTANCE TOLERANCE PER SECTION IN PERCENTSINGLE SECTION -10.0 TO 10.0
ACTUATOR TRAVEL CONTROL FEATURECLUTCH
AMBIENT TEMP IN DEG CELSIUS PER SECTION AT FULL RATED POWERSINGLE SECTION 25.0
SHAFT BEARING TYPESLEEVE
PROPRIETARY CHARACTERISTICSPACS
TERMINAL TYPE AND QUANTITYPIN 3

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabSupp collabFmr MOE rl
ZW01ZW01-DEC-05ZW81ZW
A918DA5C01-JAN-08ZAZGX01CD5DCD GXAZ
MC49DM5C01-JAN-08ZPAGX01PA5DGX PA
N9BNDN5C01-APR-06ZHDGX01GH5DGXHDN9ND

Service data

Army

Matcat 1
Q
Matcat 2
2
Matcat 3
2
Matcat 4 5
00
ARC
X

Navy

COG
9B

Marine Corps

SAC
1
CEC
5
MEC
B2

Freight

ACTY CD
TX
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
72D
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
A
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
ZZ
Special requirements apply that are not represented by the code symbols; details are provided with the acquisition...
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
ZZ
Special requirement – See specific instructions or drawings provided
Wrap mat
ZZ
Special requirements – see specific instructions or drawings provided
Cush dun
ZZ
Special requirements.
THK
C
3/4 inch thick
Unit cont
ZZ
Special requirement – See specific instructions or drawings provided.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
ZZ
Special requirements
Inter cont
ZZ
Special requirement – See specific instructions or drawings provided.
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
0.1000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0030
OPI
M
All packaging data is mandatory for compliance and no substitutions are permitted.
Supplemental instructions
UNIT PACKAGE MARKING REQUI

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
C
Orig stdzn dec
TX
Dt stdzn dec
04-AUG-1990
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.