Catalog item

RESISTOR NETWORK,FIXED,FILM

5905FSC
01NCB code
239-2001Item number
NIIN 01-239-2001
Request a quote
Unit price
$10.83
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
32068
PINC
0032068
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
26-AUG-86
Precious metals indicator
A
Hazardous material indicator
N
ESD/EMI code
B
Schedule B export code
8533100057

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DAZSMSEA0.0000$10.831U0ZQ2200X-$0.00A
01-OCT-2026DFZSMSEA0.0000$10.831U0NSF9EH-N$0.00F
01-OCT-2026DNZSMSEA0.0000$10.831U09B-----$0.00N
01-OCT-2026DSZSMSEA0.0000$10.831U0N-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNSC
MIL-R-83401/981349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A59ETXB
M8340109M5101GG81349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A22ETX
MIL-PRF-83401/981349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A41EZZ

Characteristics

TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS-300.0 TO 300.0
ELECTRICAL RESISTANCEEACH RESISTOR KILOHMS 5.100
RESISTANCE TOLERANCE IN PERCENT-2.000 TO 2.000
AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER70.0
AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER125.0
TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS-55.0 TO 125.0
INCLOSURE METHODENCAPSULATED
TERMINAL QUANTITY10
RELIABILITY INDICATORNOT ESTABLISHED
TERMINAL LENGTHINCHES NOMINAL 0.135
BODY LENGTHINCHES NOMINAL 0.983
BODY WIDTHINCHES NOMINAL 0.074
BODY HEIGHTINCHES NOMINAL 0.187
SCHEMATIC DIAGRAM DESIGNATOR
POWER DISSIPATION RATING IN WATTSLOCATION NOT OTHERWISE SPECIFIED TOTAL NETWORK 0.600
TERMINAL WIDTHINCHES NOMINAL 0.020
END ITEM IDENTIFICATIONF-15E ACFT
CUBIC MEASURECUBIC INCHES 0.014
IDENTICAL VALUE RESISTOR QUANTITY5
TERMINAL TYPEPIN
UNPACKAGED UNIT WEIGHTGRAMS 1.6
STYLE DESIGNATOR
TEST DATA DOCUMENTSPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 81349--IL-R-83401
SPECIFICATION/STANDARD DATAGOVERNMENT SPECIFICATION 81349--IL-R-83401 TO 9

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabSupp collabFmr MOE rl
WP01WP01-JUN-07WP81WP
YW01YW01-JUL-17YW81YW
ZH01ZH01-MAR-10ZH81ZH
A918DA1T01-APR-06ZCLGX01CD5DCD GXCLA196
FXGXDF1T01-APR-06ZSXGX01SX5DGX TUFXTX
N9BNDN1T01-APR-06ZKEGX01GH5DGXKE GTN9ND

Service data

Army

Matcat 1
Q
Matcat 2
2
Matcat 3
2
Matcat 4 5
00
ARC
X

Navy

COG
9B

Air Force

Fund
SF
Budget
9
MMAC
EH
PVC
N
ERRC
N

Freight

ACTY CD
TH
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
72D
Type of cargo code
3
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
A
Intermediate container qty
100
100 unit packs per intermediate container
Method of preservation
GX
Preserve by Method 41 using an approved ESD control program (see 5.2.4.1.1) as follows: Items subject to damage by...
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
00
No requirement
Cush dun
NB
A-A-3129, Type I, Grade B, static dissipative open cell plastic cushioning.
THK
A
1/4 inch thick
Unit cont
B9
MIL-DTL-117, Type I, Class F, Style 1, heavy duty, watervaporproof, electrostatic protective, opaque bag.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
ZZ
Special requirements
Inter cont
E5
ASTM D5118/D5118M, fiberboard box.
Lvl A
E
Packing shall be accomplished to meet the performance test requirements of ASTM D4169, Distribution Cycle 18,...
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
0.1000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0030
OPI
M
All packaging data is mandatory for compliance and no substitutions are permitted.
Supplemental instructions
CUSH/DUNN MAT: ZZ # CUSHIO

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
88090

Full packaging code breakdown

Related items

Standardization

Item standardization code
2
Orig stdzn dec
TX
Dt stdzn dec
28-MAR-1990
NIIN status code
0

Request a quote