Catalog item
Request a quoteRESISTOR,THERMAL
5905FSC
01NCB code
259-3785Item number
NIIN 01-259-3785
- Unit price
- $17.18
- Unit of issue
- EA
- Source of supply
- SMS
- DEMIL code
- A
Identification
- Item name code
- 00309
- PINC
- 0000309
- Criticality code
- X
- II
- 0
- DEMIL code
- A
- DEMIL integrity code
- 1
- NIIN assigned
- 17-JUL-87
- Precious metals indicator
- A
- Hazardous material indicator
- N
- Schedule B export code
- 8533400080
- FedMall
- Y
Management
| Effective date | Major organizational entity | Acquisition advice code | Source of supply | Unit of issue | Unit of measure quantity | Unit price | Quantity per unit pack | Controlled inventory item code | Shelf-life code | Management control | Net price | USC |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 01-OCT-2026 | DN | J | SMS | EA | 0.0000 | $17.18 | 1 | U | 0 | 9B----- | $0.00 | N |
| 01-OCT-2026 | DS | J | SMS | EA | 0.0000 | $17.18 | 1 | U | 0 | ------- | $0.00 | I |
Part numbers
Characteristics
| RELIABILITY INDICATOR | NOT ESTABLISHED |
|---|---|
| TERMINAL LENGTH | INCHES MINIMUM 1.000 |
| BODY OUTSIDE DIAMETER | INCHES MAXIMUM 0.125 |
| TERMINAL DIAMETER | INCHES NOMINAL 0.015 |
| AMBIENT TEMP AT FULL RATED POWER | CELSIUS 25.0 |
| MAXIMUM OPERATING TEMP | CELSIUS 125.0 |
| ZERO POWER TEMP COEFFICIENT OF RESISTANCE IN PERCENT PER DEG CELSIUS | M3.90 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | SIXTH RESISTANCE-TEMPERATURE POINT CELSIUS 60.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | TENTH RESISTANCE-TEMPERATURE POINT CELSIUS 125.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | SECOND RESISTANCE-TEMPERATURE POINT CELSIUS -30.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | FIFTH RESISTANCE-TEMPERATURE POINT CELSIUS 30.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | FOURTH RESISTANCE-TEMPERATURE POINT CELSIUS 0.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | EIGHTH RESISTANCE-TEMPERATURE POINT CELSIUS 100.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | NINTH RESISTANCE-TEMPERATURE POINT CELSIUS 115.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | THIRD RESISTANCE-TEMPERATURE POINT CELSIUS -10.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | FIRST RESISTANCE-TEMPERATURE POINT CELSIUS -50.0 |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | SEVENTH RESISTANCE-TEMPERATURE POINT CELSIUS 80.0 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | SECOND RESISTANCE-TEMPERATURE POINT KILOHMS 103.156 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | FIFTH RESISTANCE-TEMPERATURE POINT KILOHMS 6.77402 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | SEVENTH RESISTANCE-TEMPERATURE POINT KILOHMS 1.30544 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | EIGHTH RESISTANCE-TEMPERATURE POINT OHMS 756.86 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | FIRST RESISTANCE-TEMPERATURE POINT KILOHMS 328.492 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | NINTH RESISTANCE-TEMPERATURE POINT OHMS 521.52 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | SIXTH RESISTANCE-TEMPERATURE POINT KILOHMS 2.38948 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | THIRD RESISTANCE-TEMPERATURE POINT KILOHMS 37.1214 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | FOURTH RESISTANCE-TEMPERATURE POINT KILOHMS 23.3536 |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | TENTH RESISTANCE-TEMPERATURE POINT OHMS 413.28 |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -6.3 TO 6.3 |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -2.6 TO 2.6 |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -5.0 TO 5.0 |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -7.5 TO 7.5 |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -8.1 TO 8.1 |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -4.3 TO 4.3 |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -7.6 TO 7.6 |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -10.2 TO 10.2 |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -8.9 TO 8.9 |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -5.3 TO 5.3 |
| INCLOSURE TYPE | UNINCLOSED |
| ZERO POWER RESISTANCE | KILOHMS 8.200 |
| ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP | -2.0 TO 2.0 |
| REFERENCE TEMP IN DEG CELSIUS | 25.0 |
| SURFACE TREATMENT | TERMINAL SOLDER |
| STYLE DESIGNATOR | |
| TEST DATA DOCUMENT | DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) 03640-6135475 |
| TERMINAL TYPE AND QUANTITY | WIRE LEAD 2 |
MOE rules
- MOE rule
- N9BN
- MOE CD
- DN
- AMC
- 1
- AMSC
- C
- Date assigned
- 01-JUL-05
- IMC
- Z
- IMCA
- KE
- PICA
- GX
- PICA LOA
- 01
- SICA
- GH
- SICA LOA
- 5D
- Auth collab
- GX
- Supp collab
- KE
- Fmr MOE rl
- N9ND
Service data
Navy
- COG
- 9B
Freight
- ACTY CD
- TX
- NMFC
- 061700
- NMFC sub
- Z
- Uniform freight class
- 34580
- Less than truckload
- W
- Water commodity code
- 72D
- Type of cargo code
- Z
- Special handling code
- 9
- Air dimension code
- A
- Air commodity code
- HZ
- NMF description
- ELEC APPLIANCES/INSTRUMENTS NOI
Packaging
Unit and preservation
- PICA SICA
- P
- PKG cat
- 69F0
- Unpackaged weight
- 0.0000
- Unpackaged width
- 0.000
- Unpackaged length
- 0.000
- Unpackaged height
- 0.000
- TOS
- A
- Intermediate container qty
- AAAQuantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
- Method of preservation
- 41Watervaporproof bag, heat sealed
- Clng drying
- 1Any suitable process that is not injurious to the item.
- Pres mat
- 00No requirement
- Wrap mat
- 00No requirement
- Cush dun
- NAPPP-C-795, closed cell plastic cushioning; or A-A-3129, open cell plastic cushioning; or PPP-C-1797, polypropylene...
- THK
- C3/4 inch thick
- Unit cont
- D3PPP-B-566, PPP-B-676, or ASTM D5118/D5118M, folding, setup or fiberboard box.
- PKG data source
- P
Unit pack
- PICA SICA
- P
- SPC MKG
- ZZSpecial requirements
- Inter cont
- D3PPP-B-566, PPP-B-676, or ASTM D5118/D5118M, folding, setup or fiberboard box.
- Lvl A
- QPacking shall be accomplished in accordance with table C.II for the packing level specified.
- Lvl b
- QPacking shall be accomplished in accordance with table C-II for the packing level specified.
- Unit pack weight
- 0.0000
- UP SZ MAXB
- 0.00000
- UP SZ MAXL
- 0.00000
- UP SZ MAXH
- 0.00000
- Unit pack cube
- 0.0000
- OPI
- MAll packaging data is mandatory for compliance and no substitutions are permitted.
- Supplemental instructions
- UNIT PACKAGE MARKING REQUI
Packaging instructions
- PICA SICA
- P
- PKG design ACTY
- 14933
- SPI date
- 00000
Related items
Standardization
- Item standardization code
- 5
- Orig stdzn dec
- 97
- Dt stdzn dec
- 17-JUL-1987
- NIIN status code
- 0
Request a quote
Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.