Catalog item

RESISTOR,THERMAL

5905FSC
01NCB code
271-4566Item number
NIIN 01-271-4566
Request a quote
Unit price
$16.49
Unit of issue
EA
Source of supply
FPD
DEMIL code
A

Identification

Item name code
00309
PINC
0000309
Criticality code
X
II
M
DEMIL code
A
NIIN assigned
25-JAN-88
Precious metals indicator
A
ADP equipment code
0
Hazardous material indicator
N
ESD/EMI code
B
Schedule B export code
8533400080

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-MAR-1995DFDFPDEA0.0000$16.491U0NROKKE-V$0.00F
01-MAR-1995DFDFPDEA0.0000$16.491U0NROKKE-V$0.00I

Part numbers

Part number
0N516296-8
CAGE
98230
NATIONAL SECURITY AGENCY
CAGE status
A
RNCC
3
RNVC
2
Document availability code
D
RNAAC
SJ

Characteristics

RELIABILITY INDICATORNOT ESTABLISHED
BODY LENGTHINCHES MINIMUM 2.890 AND INCHES MAXIMUM 2.930
BODY OUTSIDE DIAMETERINCHES MINIMUM 0.022 AND INCHES MAXIMUM 0.028
MAXIMUM POWER DISSIPATION RATINGMILLIWATTS 500.000
AMBIENT TEMP AT FULL RATED POWERCELSIUS 25.0
MAXIMUM OPERATING TEMPCELSIUS 125.0
THERMAL TIME CONSTANT IN SECONDS120.0
POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS10.0
ZERO POWER TEMP COEFFICIENT OF RESISTANCE IN PERCENT PER DEG CELSIUS0.55
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWERFIRST RESISTANCE-TEMPERATURE POINT CELSIUS -55.0
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWERSECOND RESISTANCE-TEMPERATURE POINT CELSIUS -15.0
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWERTHIRD RESISTANCE-TEMPERATURE POINT CELSIUS 50.0
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWERFIFTH RESISTANCE-TEMPERATURE POINT CELSIUS 100.0
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWERSIXTH RESISTANCE-TEMPERATURE POINT CELSIUS 125.0
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWERFOURTH RESISTANCE-TEMPERATURE POINT CELSIUS 75.0
ZERO POWER RESISTANCE AT SPECIFIED TEMPFIRST RESISTANCE-TEMPERATURE POINT OHMS 825.0
ZERO POWER RESISTANCE AT SPECIFIED TEMPFOURTH RESISTANCE-TEMPERATURE POINT KILOHMS 2.1
ZERO POWER RESISTANCE AT SPECIFIED TEMPSIXTH RESISTANCE-TEMPERATURE POINT KILOHMS 2.9
ZERO POWER RESISTANCE AT SPECIFIED TEMPSECOND RESISTANCE-TEMPERATURE POINT KILOHMS 1.1
ZERO POWER RESISTANCE AT SPECIFIED TEMPTHIRD RESISTANCE-TEMPERATURE POINT KILOHMS 1.8
ZERO POWER RESISTANCE AT SPECIFIED TEMPFIFTH RESISTANCE-TEMPERATURE POINT KILOHMS 2.5
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-9.0 TO 9.0
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-12.0 TO 12.0
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-7.0 TO 7.0
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-15.0 TO 15.0
END ITEM IDENTIFICATIONKI-31;HVT
INCLOSURE TYPEENCAPSULATED
ZERO POWER RESISTANCEOHMS 1500.000
ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP-5.0 TO 5.0
PROPRIETARY CHARACTERISTICSPACS
STYLE DESIGNATOR
TEST DATA DOCUMENTSPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 81349--IL-T-23648
TERMINAL TYPE AND QUANTITYWIRE LEAD 2
SPECIFICATION/STANDARD DATAGOVERNMENT SPECIFICATION 81349--IL-T-23648 TO 9

MOE rules

MOE rule
FJ5N
MOE CD
DF
AMC
3
AMSC
C
Date assigned
01-APR-91
IMC
F
IMCA
SJ
PICA
SJ
PICA LOA
06
Auth collab
SJ TU XP

Service data

Air Force

Fund
RO
Budget
K
MMAC
KE
PVC
V
ERRC
N

Freight

ACTY CD
SJ
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Less than carload
P
Water commodity code
72D
Type of cargo code
3
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICA
P
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
Method of preservation
GX
Preserve by Method 41 using an approved ESD control program (see 5.2.4.1.1) as follows: Items subject to damage by...
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
XX
Cush dun
XX
THK
X
Unit cont
B9
MIL-DTL-117, Type I, Class F, Style 1, heavy duty, watervaporproof, electrostatic protective, opaque bag.
PKG data source
A

Unit pack

PICA SICA
P
SPC MKG
39
ESD sensitive electronic device requirements of MIL-STD-129 apply
Inter cont
EC
ASTM D5118/D5118M, Type CF, Class domestic, corrugated fiberboard box.
Unit pack weight
10.0000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0000
OPI
M
All packaging data is mandatory for compliance and no substitutions are permitted.

Packaging instructions

PICA SICA
P
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
5
Orig stdzn dec
97
Dt stdzn dec
25-JAN-1988
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.