Catalog item

RESISTOR,VARIABLE,NONWIRE WOUND,

5905FSC
01NCB code
310-3083Item number
NIIN 01-310-3083
Request a quote
Unit price
$5.83
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
37405
PINC
0037405
Criticality code
X
II
0
DEMIL code
A
NIIN assigned
02-NOV-89
Precious metals indicator
A
Hazardous material indicator
N
ESD/EMI code
B
Schedule B export code
8533400080

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DFJSMSEA0.0000$5.831U0NSF9EH-N$0.00F
01-OCT-2026DNJSMSEA0.0000$5.831U09B-----$0.00N
01-OCT-2026DSJSMSEA0.0000$5.831U0N-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSCSADC
3006Y-1-10432997
BOURNS INC
A32ETX
206003-002664415
LEONARDO US CYBER AND SECURITY SOLUTIONS, LLC
A52548
43Y10402111
VISHAY SPRAGUE INC
AE8ETX4D
2145511837
ELECTRO SCIENTIFIC INDUSTRIES INC
RC16ZZAC

Characteristics

SECTION QUANTITY1
BODY STYLE
RELIABILITY INDICATORNOT ESTABLISHED
TERMINAL LENGTHINCHES MINIMUM 0.165
SHAFT DIAMETERINCHES MINIMUM 0.085 AND INCHES MAXIMUM 0.105
SHAFT LENGTHINCHES MINIMUM 0.050 AND INCHES MAXIMUM 0.070
BODY LENGTHINCHES MINIMUM 0.740 AND INCHES MAXIMUM 0.760
BODY WIDTHINCHES MINIMUM 0.180 AND INCHES MAXIMUM 0.200
BODY HEIGHTINCHES MINIMUM 0.240 AND INCHES MAXIMUM 0.260
SHAFT STYLE
ACTUATOR TYPESINGLE SHAFT
EFFECTIVE ELECTRICAL ROTATION IN DEG ANGULAR ROTATIONNOMINAL 5400.0
MAXIMUM STARTING TORQUEINCH-OUNCES 5.00
MAXIMUM RUNNING TORQUEINCH-OUNCES 5.00
CENTER TO CENTER DISTANCE BETWEEN TERMINALSINCHES MINIMUM 0.690 AND INCHES MAXIMUM 0.710
FRAGILITY FACTORMODERATELY RUGGED
END ITEM IDENTIFICATION6625-01-125-3775 METER,IMPEDANCE
MOUNTING METHODTERMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINAL ROWSINCHES MINIMUM 0.090 AND INCHES MAXIMUM 0.110
FEATURES PROVIDEDHUMIDITY PROOF
CUBIC MEASURECUBIC INCHES 0.040
ELECTRICAL RESISTANCE PER SECTIONKILOHMS SINGLE SECTION 100.0
ROTARY ACTUATOR TRAVEL IN ANGULAR DEGNOMINAL 5400.0
CENTER TO CENTER DISTANCE BETWEEN CENTER TERMINAL AND OUTSIDE TERMINALINCHES MINIMUM 0.290 AND INCHES MAXIMUM 0.310
AMBIENT TEMP IN DEG CELSIUS PER SECTION AT ZERO PERCENT RATED POWERSINGLE SECTION 125.0
TERMINAL LOCATIONLOWER ADJACENT SIDE TWO ROWS
POWER DISSIPATION RATING PER SECTION IN WATTSFREE AIR SINGLE SECTION 0.75
RESISTANCE TOLERANCE PER SECTION IN PERCENTSINGLE SECTION -10.0 TO 10.0
ACTUATOR TRAVEL CONTROL FEATURECLUTCH
AMBIENT TEMP IN DEG CELSIUS PER SECTION AT FULL RATED POWERSINGLE SECTION 70.0
TERMINAL TYPE AND QUANTITYPIN 3

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAAcquisition advice codePICAPICA LOASICASICA LOAAuth collabSupp collabFmr MOE rl
YJ01YJ01-JAN-09YJ81YJ
BGX1GE3Z01-APR-06GX01485DGX 48BTX1
FXGXDF3Z01-APR-06ZSXGX01SX5DGX TUFXTX
G860T10001-APR-91C864875 86
N9BNDN3Z01-APR-06ZHDGX01GH5DGXHX HDN9ND

Service data

Navy

COG
9B

Air Force

Fund
SF
Budget
9
MMAC
EH
PVC
N
ERRC
N

Freight

ACTY CD
TX
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
72D
Type of cargo code
3
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
A
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
ZZ
Special requirements apply that are not represented by the code symbols; details are provided with the acquisition...
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
ZZ
Special requirement – See specific instructions or drawings provided
Wrap mat
ZZ
Special requirements – see specific instructions or drawings provided
Cush dun
ZZ
Special requirements.
THK
C
3/4 inch thick
Unit cont
ZZ
Special requirement – See specific instructions or drawings provided.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
ZZ
Special requirements
Inter cont
ZZ
Special requirement – See specific instructions or drawings provided.
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
0.1000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0030
OPI
M
All packaging data is mandatory for compliance and no substitutions are permitted.
Supplemental instructions
UNIT PACKAGE MARKING REQUI

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
92329

Full packaging code breakdown

Related items

Standardization

Item standardization code
5
Orig stdzn dec
9Z
Dt stdzn dec
01-JAN-2009
NIIN status code
0

Cancelled and replaced NIINs

FSC
5905
Cancelled NIIN
5905-01-129-3318
NIIN status code
5
Effective date
02-JUL-2026
DEMIL code
A

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.