Catalog item

RESISTOR,THERMAL

5905FSC
01NCB code
360-6629Item number
NIIN 01-360-6629
Request a quote
Unit price
$4,358.05
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
00309
PINC
0000309
Criticality code
X
II
0
DEMIL code
A
NIIN assigned
29-JUN-92
Precious metals indicator
A
Hazardous material indicator
N
ESD/EMI code
B
Schedule B export code
8533400080

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DAJSMSEA0.0000$4,358.051U0ZQ2200X-$0.00A
01-OCT-2026DFJSMSEA0.0000$4,358.051U0NSF9EH-N$0.00F
01-OCT-2026DSJSMSEA0.0000$4,358.051U0N-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNSC
MIL-PRF-23648/181349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A41EZZ
MIL-R-23648/181349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A59ETXB
RTH06AS591F81349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A59EZZB
RTH06AS511F81349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A22ETXD

Characteristics

RELIABILITY INDICATORNOT ESTABLISHED
TERMINAL LENGTHINCHES MINIMUM 1.500
BODY OUTSIDE DIAMETERINCHES MINIMUM 0.200 AND INCHES MAXIMUM 0.300
BODY WIDTHINCHES MAXIMUM 0.260
TERMINAL DIAMETERINCHES MINIMUM 0.017 AND INCHES MAXIMUM 0.023
MAXIMUM POWER DISSIPATION RATINGMICROWATTS 0.50
AMBIENT TEMP AT FULL RATED POWERCELSIUS 25.0
MAXIMUM OPERATING TEMPCELSIUS 125.0
THERMAL TIME CONSTANT IN SECONDS80.0
POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS5.0
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWERFIRST RESISTANCE-TEMPERATURE POINT CELSIUS -55.0
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWERSIXTH RESISTANCE-TEMPERATURE POINT CELSIUS 100.0
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWERSECOND RESISTANCE-TEMPERATURE POINT CELSIUS -15.0
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWERFIFTH RESISTANCE-TEMPERATURE POINT CELSIUS 75.0
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWERFOURTH RESISTANCE-TEMPERATURE POINT CELSIUS 50.0
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWERSEVENTH RESISTANCE-TEMPERATURE POINT CELSIUS 125.0
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWERTHIRD RESISTANCE-TEMPERATURE POINT CELSIUS 0.0
ZERO POWER RESISTANCE AT SPECIFIED TEMPFIFTH RESISTANCE-TEMPERATURE POINT OHMS 93.84
ZERO POWER RESISTANCE AT SPECIFIED TEMPFOURTH RESISTANCE-TEMPERATURE POINT OHMS 206.55
ZERO POWER RESISTANCE AT SPECIFIED TEMPSEVENTH RESISTANCE-TEMPERATURE POINT OHMS 25.653
ZERO POWER RESISTANCE AT SPECIFIED TEMPFIRST RESISTANCE-TEMPERATURE POINT KILOHMS 27.999
ZERO POWER RESISTANCE AT SPECIFIED TEMPTHIRD RESISTANCE-TEMPERATURE POINT KILOHMS 1.4535
ZERO POWER RESISTANCE AT SPECIFIED TEMPSECOND RESISTANCE-TEMPERATURE POINT KILOHMS 2.9427
ZERO POWER RESISTANCE AT SPECIFIED TEMPSIXTH RESISTANCE-TEMPERATURE POINT OHMS 47.073
DISTANCE BETWEEN MOUNTING FACILITY CENTERSINCHES MAXIMUM 0.180
INCLOSURE TYPEENCAPSULATED
ZERO POWER RESISTANCEOHMS 510.000
ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP-1.0 TO 1.0
STYLE DESIGNATOR
TEST DATA DOCUMENTSPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 81349--IL-R-23648
TERMINAL TYPE AND QUANTITYWIRE LEAD 2
SPECIFICATION/STANDARD DATAGOVERNMENT SPECIFICATION 81349--IL-R-23648 TO 1

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabSupp collabFmr MOE rl
YR01YR01-JAN-24YR81YR
A918DA1T01-APR-16ZBFGX01CD5DCD GXBF
FXGXDF1T01-APR-06ZSXGX01SX5DGX TUFXTX

Service data

Army

Matcat 1
Q
Matcat 2
2
Matcat 3
2
Matcat 4 5
00
ARC
X

Air Force

Fund
SF
Budget
9
MMAC
EH
PVC
N
ERRC
N

Freight

ACTY CD
TH
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
72D
Type of cargo code
3
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69FZ
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
A
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
ZZ
Special requirements apply that are not represented by the code symbols; details are provided with the acquisition...
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
ZZ
Special requirement – See specific instructions or drawings provided
Wrap mat
ZZ
Special requirements – see specific instructions or drawings provided
Cush dun
ZZ
Special requirements.
THK
C
3/4 inch thick
Unit cont
ZZ
Special requirement – See specific instructions or drawings provided.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
ZZ
Special requirements
Inter cont
ZZ
Special requirement – See specific instructions or drawings provided.
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
1.0000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0010
OPI
M
All packaging data is mandatory for compliance and no substitutions are permitted.
Supplemental instructions
UNIT PACKAGE MARKING REQUI

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
5
Orig stdzn dec
97
Dt stdzn dec
29-JUN-1992
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.