Catalog item

CAPACITOR,FIXED,ELECTROLYTIC

5910FSC
00NCB code
010-8109Item number
NIIN 00-010-8109
Request a quote
Unit price
$60.01
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
00008
PINC
0000008
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
04-OCT-72
Precious metals indicator
U
Hazardous material indicator
P
Schedule B export code
8532290040

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DSJSMSEA0.0000$60.011U0N-------$0.00I
01-OCT-2026DFJSMSEA0.0000$60.011U0NSF9EH-N$0.00F

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSCSADC
111D106X0100MD56289
SPRAGUE ELECTRIC CO WORLD HQS
AC13TU4DAF
MIL-C-39006/481349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A413TX
M39006/04-131281349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A223TX4D

Characteristics

RELIABILITY FAILURE RATE LEVEL IN PERCENT0.1000
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTIONDC SINGLE SECTION 100.0
TOLERANCE RANGE PER SECTIONPERCENT SINGLE SECTION -20.00 TO 20.00
MIL-STD-1276 WIRE LEAD TYPE DESIGNATORN-3
TERMINAL LENGTHINCHES NOMINAL 1.500
NONDERATED OPERATING TEMPCELSIUS MINIMUM -55.0 AND CELSIUS MAXIMUM 85.0
DC LEAKAGE AT MAXIMUM OPERATING TEMPMILLIAMPERES 24.0
RELIABILITY INDICATORESTABLISHED
BODY DIAMETERINCHES MAXIMUM 0.406
BODY LENGTHINCHES NOMINAL 2.203
TERMINAL DIAMETERINCHES NOMINAL 0.025
SCHEMATIC DIAGRAM DESIGNATOR
ANODE TYPEPLAIN FOIL
IMPEDANCE AT MINIMUM OPERATING TEMP IN OHMS223.0
ELECTRICAL POLARIZATIONNONPOLARIZED
FEATURES PROVIDEDHERMETICALLY SEALED CASE
CAPACITANCE VALUE PER SECTIONMICROFARADS SINGLE SECTION 10.000
CAPACITIVE ELECTRODE MATERIALTANTALUM
BODY STYLE
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT10.0000
DC LEAKAGE AT REFERENCE TEMPMICROAMPERES 4.000
CASE INSULATION MATERIALPLASTIC
TEST DATA DOCUMENTSPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 81349--IL-C-39006
TERMINAL TYPE AND QUANTITYUNINSULATED WIRE LEAD 2
SPECIFICATION/STANDARD DATAGOVERNMENT SPECIFICATION 81349--IL-C-39006 TO 4

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabFmr MOE rl
YA01YA01-JAN-02YA81YA
YB01YB01-APR-91YB81YB
ZR01ZR01-JUL-97ZR81ZR
ZU01ZU01-APR-91ZU81ZU
ZW01ZW01-DEC-95ZW81ZW
FXGXDF1T01-JUN-06ZSXGX01SX5DGX TUFXTX

Service data

Air Force

Fund
SF
Budget
9
MMAC
EH
PVC
N
ERRC
N

Freight

ACTY CD
TX
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
72D
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
A
Intermediate container qty
XXX
Method of preservation
ZZ
Special requirements apply that are not represented by the code symbols; details are provided with the acquisition...
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
ZZ
Special requirement – See specific instructions or drawings provided
Wrap mat
ZZ
Special requirements – see specific instructions or drawings provided
Cush dun
ZZ
Special requirements.
THK
C
3/4 inch thick
Unit cont
ZZ
Special requirement – See specific instructions or drawings provided.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
ZZ
Special requirements
Inter cont
ZZ
Special requirement – See specific instructions or drawings provided.
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
0.1000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0070
OPI
M
All packaging data is mandatory for compliance and no substitutions are permitted.
Supplemental instructions
PRESERVATION AND PACKAGING

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Related NSNItem standardization codeOrig stdzn decDt stdzn decNIIN status code
3TX03-JUN-19950
BTX31-MAY-19950
ETX03-JUN-19950
5910-00-082-50403TX03-JUN-19950
5910-00-952-88463TX03-JUN-19950
5910-00-110-7331ETX03-JUN-19950

Cancelled and replaced NIINs

FSCCancelled NIINNIIN status codeEffective dateDEMIL code
59105910-00-061-4436522-JUL-2026A
59105910-00-578-5757501-JUL-2026A
59105910-01-207-1040502-JUL-2026A

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.