Catalog item

CAPACITOR,FIXED,CERAMIC DIELECTR

5910FSC
00NCB code
062-0931Item number
NIIN 00-062-0931
Request a quote
Unit price
$19.81
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
00007
PINC
0000007
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
20-JUN-67
Precious metals indicator
U
Hazardous material indicator
P
Schedule B export code
8532290040

Management

Effective date
01-OCT-2026
Major organizational entity
DS
Acquisition advice code
J
Source of supply
SMS
Unit of issue
EA
Unit of measure quantity
0.0000
Unit price
$19.81
Quantity per unit pack
1
Controlled inventory item code
U
Shelf-life code
0
Management control
-------
Net price
$0.00
USC
I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
258252-4637695
RAYTHEON COMPANY
A526TX3D
STSWC038-22498897
LOCKHEED MARTIN CORP DIV LOCKHEED MARTIN AERONAUTICS COMPANY
A325TA3D
207030-1609017
EDO
H591TXB

Characteristics

BODY HEIGHTINCHES MAXIMUM 0.150
TERMINAL DIAMETERINCHES NOMINAL 0.025
SCHEMATIC DIAGRAM DESIGNATOR
CAPACITANCE VALUE PER SECTIONMICROFARADS SINGLE SECTION 0.220
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES MINIMUM 0.185 AND INCHES MAXIMUM 0.215
BODY LENGTHINCHES MAXIMUM 0.300
BODY WIDTHINCHES MAXIMUM 0.300
TERMINAL LENGTHINCHES MINIMUM 1.250
BODY STYLE
RELIABILITY INDICATORNOT ESTABLISHED
MATERIALCASE PLASTIC
TEST DATA DOCUMENTDRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) 50222-2070
TERMINAL TYPE AND QUANTITYUNINSULATED WIRE LEAD 2
INSULATION RESISTANCE AT REFERENCE TEMPMEGOHM-MICROFARADS 1000.0
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT0.0200
TERMINAL SURFACE TREATMENTSOLDER
TOLERANCE RANGE PER SECTIONPERCENT SINGLE SECTION -10.00 TO 10.00
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTIONDC SINGLE SECTION 100.0
NONDERATED OPERATING TEMPCELSIUS MINIMUM -15.0 AND CELSIUS MAXIMUM 70.0

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedPICAPICA LOAAuth collab
ZG01ZG01-NOV-11ZG81ZG
DGX1DS1L01-NOV-25GX01GX

Freight

ACTY CD
TX
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
72D
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
A
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
41
Watervaporproof bag, heat sealed
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
00
No requirement
Cush dun
00
No requirement
THK
0
Not applicable
Unit cont
D3
PPP-B-566, PPP-B-676, or ASTM D5118/D5118M, folding, setup or fiberboard box.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
ZZ
Special requirements
Inter cont
DO
Any suitable fiber box included in this table may be used (see J.4.9.1).
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
0.1000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0010
OPI
M
All packaging data is mandatory for compliance and no substitutions are permitted.
Supplemental instructions
UNIT PACKAGE MARKING REQUI

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
C
Orig stdzn dec
TX
Dt stdzn dec
31-OCT-1986
NIIN status code
0

Cancelled and replaced NIINs

FSC
5910
Cancelled NIIN
5910-00-146-5003
NIIN status code
7
Effective date
02-JUL-2026
DEMIL code
A

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.