Catalog item

CAPACITOR,FIXED,CERAMIC DIELECTR

5910FSC
00NCB code
097-7616Item number
NIIN 00-097-7616
Request a quote
Unit price
$6.99
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
00007
PINC
0000007
Criticality code
X
II
0
DEMIL code
A
NIIN assigned
05-JUN-68
Precious metals indicator
U
Hazardous material indicator
P
Schedule B export code
8532290040
FedMall
Y

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DAJSMSEA0.0000$6.991U0ZQ2200X-$0.00A
01-OCT-2026DFJSMSEA0.0000$6.991U0NSF9EH-N$0.00F
01-OCT-2026DSJSMSEA0.0000$6.991U0N-------$0.00I
01-OCT-2026GPJSMSEA0.0000$6.991U0-------$0.00C

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
CC53CG680J81349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A593TXB
MIL-C-20/1981349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A413TXD
CC53CG680G81349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A223TX3D

Characteristics

SCHEMATIC DIAGRAM DESIGNATOR
INSULATION RESISTANCE AT MAXIMUM OPERATING TEMPMEGOHMS 1000.0
CAPACITANCE VALUE PER SECTIONPICOFARADS SINGLE SECTION 68.000
NONDERATED OPERATING TEMPCELSIUS MINIMUM -55.0 AND CELSIUS MAXIMUM 125.0
TEMP COEFFICIENT OF CAPACITANCE PER SECTION IN PPM PER DEG CELSIUSSINGLE SECTION 0.0
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTIONDC SINGLE SECTION 500.0
TOLERANCE OF TEMP COEFFICIENT PER SECTION IN PPM PER DEG CELSIUSSINGLE SECTION -30.0 TO 30.0
TOLERANCE RANGE PER SECTIONPERCENT SINGLE SECTION -2.00 TO 2.00
INSULATION RESISTANCE AT REFERENCE TEMPMEGOHMS 50000.0
TERMINAL SURFACE TREATMENTSOLDER
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO DIAMETERINCHES MINIMUM 0.315 AND INCHES MAXIMUM 0.435
BODY STYLE
RELIABILITY INDICATORNOT ESTABLISHED
TERMINAL LENGTHINCHES MINIMUM 1.250
BODY DIAMETERINCHES NOMINAL 0.720
BODY LENGTHINCHES NOMINAL 0.120
TERMINAL TYPE AND QUANTITYUNINSULATED WIRE LEAD 2
TEST DATA DOCUMENTSPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 81349--IL-C-20 TO 19

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabFmr MOE rl
A918DA1T01-JUN-06ZCDGX01CD5DCD GXA196
C911GP1T01-JUN-06GX01XG5DXG GXC007
FXGXDF1T01-JUN-06ZSXGX01SX5DGX TUFXTX

Service data

Army

Matcat 1
Q
Matcat 2
2
Matcat 3
2
Matcat 4 5
00
ARC
X

Air Force

Fund
SF
Budget
9
MMAC
EH
PVC
N
ERRC
N

Freight

ACTY CD
TX
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
72D
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
A
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
41
Watervaporproof bag, heat sealed
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
00
No requirement
Cush dun
00
No requirement
THK
0
Not applicable
Unit cont
D3
PPP-B-566, PPP-B-676, or ASTM D5118/D5118M, folding, setup or fiberboard box.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
ZZ
Special requirements
Inter cont
DO
Any suitable fiber box included in this table may be used (see J.4.9.1).
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
0.1000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0100
OPI
M
All packaging data is mandatory for compliance and no substitutions are permitted.
Supplemental instructions
UNIT PACKAGE MARKING REQUI

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
5
Orig stdzn dec
TX
Dt stdzn dec
01-FEB-2000
NIIN status code
0

Cancelled and replaced NIINs

FSCCancelled NIINNIIN status codeEffective dateDEMIL code
59105910-00-110-0845502-JUL-2026A
59105910-00-912-8981502-JUL-2026A

Request a quote