Catalog item

CAPACITOR,FIXED,CERAMIC DIELECTR

5910FSC
00NCB code
161-4431Item number
NIIN 00-161-4431
Request a quote
Unit price
$1.61
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
00007
PINC
0000007
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
03-NOV-71
Precious metals indicator
A
ADP equipment code
0
Hazardous material indicator
P
Schedule B export code
8532290040

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DAZSMSEA0.0000$1.611U0ZQ22TLX-$0.00A
01-OCT-2026DFZSMSEA0.0000$1.611U0NSF9EH-N$0.00F
01-OCT-2026DNZSMSEA0.0000$1.611U09B-----$0.00N
01-OCT-2026DSZSMSEA0.0000$1.611U0N-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSCSADC
258330-619237695
RAYTHEON COMPANY
A5229ZD
150-100-NP0-4R7D51642
CENTRE CAPACITOR INC
A5259ZD
8101A100C0G0479C72982
ERIE SPECIALTY PRODUCTS INC
A593TX1B
8101-100COHO479C72982
ERIE SPECIALTY PRODUCTS INC
AC15TXAW
8101-100COH0479D72982
ERIE SPECIALTY PRODUCTS INC
AC1548AH
8101-100C0G479G72982
ERIE SPECIALTY PRODUCTS INC
A593TX1B
8101A100C0G0-479G72982
ERIE SPECIALTY PRODUCTS INC
A593TX1B
8101A100C0G0479C18796
MURATA ERIE NORTH AMERICA INC STATE COLLEGE OPNS
H393TX1D
CN15A4R7D16546
MEPCO/CENTRALAB A NORTH AMERICAN PHILIPS CO
HC19TU4B

Characteristics

TOLERANCE RANGE PER SECTIONPERCENT SINGLE SECTION -2.00 TO 2.00
TOLERANCE OF TEMP COEFFICIENT PER SECTION IN PPM PER DEG CELSIUSSINGLE SECTION -30.0 TO 30.0
QUALITY FACTOR AT REFERENCE TEMP1000.0000
TERMINAL SURFACE TREATMENTSOLDER
MATERIALCASE PLASTIC
TERMINAL TYPE AND QUANTITYUNINSULATED WIRE LEAD 2
BODY LENGTHINCHES MAXIMUM 0.100
BODY WIDTHINCHES MAXIMUM 0.100
BODY HEIGHTINCHES MAXIMUM 0.100
BODY STYLE
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTIONDC SINGLE SECTION 100.0
SCHEMATIC DIAGRAM DESIGNATOR
CAPACITANCE VALUE PER SECTIONPICOFARADS SINGLE SECTION 4.700
NONDERATED OPERATING TEMPCELSIUS MINIMUM -55.0 AND CELSIUS MAXIMUM 150.0
TEMP COEFFICIENT OF CAPACITANCE PER SECTION IN PPM PER DEG CELSIUSSINGLE SECTION 0.0
INSULATION RESISTANCE AT REFERENCE TEMPMEGOHM-MICROFARADS 5000.0
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES MINIMUM 0.069 AND INCHES MAXIMUM 0.131
TERMINAL LENGTHINCHES MINIMUM 1.500
RELIABILITY INDICATORNOT ESTABLISHED

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAAcquisition advice codePICAPICA LOASICASICA LOAAuth collabSupp collabFmr MOE rl
YA01YA01-AUG-00YA81YA
YB01YB01-APR-91YB81YB
YD01YD01-AUG-16YD81YD
YJ01YJ01-APR-91YJ81YJ
ZC01ZC01-APR-91ZC81ZC
ZH01ZH01-APR-91ZH81ZH
ZS01ZS01-APR-91ZS81ZS
ZU01ZU01-MAR-08ZU81ZU
ZW01ZW01-NOV-98ZW81ZW
A918DA0001-JUN-06ZCDGX01CD5DCD GXBD CLA196
FXGXDF0001-JUN-06ZSXGX01SX5DGX TUFXTX
G860T10001-APR-91C864875 86
G930T10001-APR-91C934875 93
N9BNDN0001-JUN-06ZGHGX01GH5DGXHD KEN9ND
VJ01VJ01-FEB-19VJ81VJ

Service data

Army

Matcat 1
Q
Matcat 2
2
Matcat 3
2
Matcat 4 5
TL
ARC
X

Navy

COG
9B

Air Force

Fund
SF
Budget
9
MMAC
EH
PVC
N
ERRC
N

Freight

ACTY CD
TX
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
72D
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
A
Intermediate container qty
XXX
Method of preservation
ZZ
Special requirements apply that are not represented by the code symbols; details are provided with the acquisition...
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
ZZ
Special requirement – See specific instructions or drawings provided
Wrap mat
ZZ
Special requirements – see specific instructions or drawings provided
Cush dun
ZZ
Special requirements.
THK
C
3/4 inch thick
Unit cont
ZZ
Special requirement – See specific instructions or drawings provided.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
ZZ
Special requirements
Inter cont
ZZ
Special requirement – See specific instructions or drawings provided.
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
0.1000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0010
OPI
M
All packaging data is mandatory for compliance and no substitutions are permitted.
Supplemental instructions
IP056: MERCURY OR MERCURY

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Related NSNItem standardization codeOrig stdzn decDt stdzn decNIIN status code
3TX19-AUG-19870
1TX03-DEC-19770
3TX25-NOV-19770
5910-01-090-86333TX19-AUG-19870
5910-00-147-97823TX25-NOV-19770

Cancelled and replaced NIINs

FSC
5910
Cancelled NIIN
5910-00-617-4561
NIIN status code
5
Effective date
01-JUL-2026
DEMIL code
A

Request a quote