Catalog item

CAPACITOR,FIXED,CERAMIC DIELECTR

5910FSC
00NCB code
325-7170Item number
NIIN 00-325-7170
Request a quote
Unit price
$0.82
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
00007
PINC
0000007
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
28-NOV-73
Precious metals indicator
U
Hazardous material indicator
P
Schedule B export code
8532290040

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DAZSMSEA0.0000$0.821U0ZQ2200X-$0.00A
01-OCT-2026DFZSMSEA0.0000$0.821U0NSF9EH-N$0.00F
01-OCT-2026DNZSMSEA0.0000$0.821U09B-----$0.00N
01-OCT-2026DSZSMSEA0.0000$0.821U0N-------$0.00I
01-OCT-2026GPZSMSEA0.0000$0.821U0-------$0.00C

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSCSADC
CW15C103K71590
CRL COMPONENTS INC
HC16ZZAC
755002A7705-3705869
RAYTHEON COMPANY DIV RMD STRATEGIC
AC16ZZAC
CACCW15C103K0GJR5
QUESTER TANGENT CORPORATIONDIV MARINE DIV MARINE
A523YB4A
111-0001-0012115
DRS ICAS, LLC
RC15481B
CW15C103M16546
MEPCO/CENTRALAB A NORTH AMERICAN PHILIPS CO
HC19TU4B
CW15C103K16546
MEPCO/CENTRALAB A NORTH AMERICAN PHILIPS CO
H393TX3D

Characteristics

TERMINAL TYPE AND QUANTITYUNINSULATED WIRE LEAD 2
SCHEMATIC DIAGRAM DESIGNATOR
MATERIALCASE PLASTIC
BODY LENGTHINCHES MAXIMUM 0.150
BODY WIDTHINCHES MAXIMUM 0.150
BODY STYLE
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT2.5000
NONDERATED OPERATING TEMPCELSIUS MINIMUM -55.0 AND CELSIUS MAXIMUM 125.0
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTIONDC SINGLE SECTION 50.0
TERMINAL SURFACE TREATMENTSOLDER
INSULATION RESISTANCE AT REFERENCE TEMPMEGOHMS 100000.0
CAPACITANCE VALUE PER SECTIONPICOFARADS SINGLE SECTION 10000.000
RELIABILITY INDICATORNOT ESTABLISHED
TERMINAL LENGTHINCHES MINIMUM 1.250
VOLTAGE TEMP LIMITS PER SECTION IN PERCENT CAPACITANCE CHANGEWITHOUT VOLTAGE APPLIED SINGLE SECTION -15.0 TO 15.0
TOLERANCE RANGE PER SECTIONPERCENT SINGLE SECTION -10.00 TO 10.00
BODY HEIGHTINCHES MAXIMUM 0.100
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES MINIMUM 0.069 AND INCHES MAXIMUM 0.131

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAAcquisition advice codePICAPICA LOASICASICA LOAAuth collabSupp collabFmr MOE rl
WP01WP01-MAR-05WP81WP
WG01WG01-OCT-17WG81WG
YA01YA01-AUG-00YA81YA
YC01YC01-JUL-15YC81YC
YB01YB01-APR-91YB81YB
ZC01ZC01-APR-91ZC81ZC
ZH01ZH01-APR-91ZH81ZH
ZR01ZR01-JUL-97ZR81ZR
ZU01ZU01-APR-91ZU81ZU
ZW01ZW01-NOV-98ZW81ZW
A918DA3Z01-JUN-06ZCDGX01CD5DCD GXCLA196
C911GP3Z01-JUN-06GX01XG5DXG GXC007
FXGXDF3Z01-JUN-06ZSXGX01SX5DGX TUFXTX
G860T10001-APR-91C864875 86
G280T10001-APR-91C284828 75
N9BNDN3Z01-JUN-06ZHDGX01GH5DGXGT KE HDN9ND

Service data

Army

Matcat 1
Q
Matcat 2
2
Matcat 3
2
Matcat 4 5
00
ARC
X

Navy

COG
9B

Air Force

Fund
SF
Budget
9
MMAC
EH
PVC
N
ERRC
N

Freight

ACTY CD
TX
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
72D
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
A
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
ZZ
Special requirements apply that are not represented by the code symbols; details are provided with the acquisition...
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
ZZ
Special requirement – See specific instructions or drawings provided
Wrap mat
ZZ
Special requirements – see specific instructions or drawings provided
Cush dun
ZZ
Special requirements.
THK
C
3/4 inch thick
Unit cont
ZZ
Special requirement – See specific instructions or drawings provided.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
ZZ
Special requirements
Inter cont
ZZ
Special requirement – See specific instructions or drawings provided.
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
0.1000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0240
OPI
M
All packaging data is mandatory for compliance and no substitutions are permitted.
Supplemental instructions
PRESERVATION AND PACKAGING

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
2
Orig stdzn dec
TX
Dt stdzn dec
14-MAY-1985
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.