Catalog item

CAPACITOR,FIXED,ELECTROLYTIC

5910FSC
00NCB code
439-0652Item number
NIIN 00-439-0652
Request a quote
Unit price
$3.90
Unit of issue
EA
Source of supply
SMS
DEMIL code
Q

Identification

Item name code
00008
PINC
0000008
Criticality code
Y
II
0
DEMIL code
Q
DEMIL integrity code
3
NIIN assigned
05-DEC-69
Precious metals indicator
U
Hazardous material indicator
P
Schedule B export code
8532290040

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DFJSMSEA0.0000$3.901U0NSF9EH-N$0.00F
01-OCT-2026DNJSMSEA0.0000$3.901U09B-----$0.00N
01-OCT-2026DSJSMSEA0.0000$3.901U0N-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSCSADC
76F02FF75019209
ENERGIZER POWER SYSTEMS
HC16ZZAC
0180-183828480
HEWLETT-PACKARD COMPANY DBA HP
A591TX4B
07078430A50423
BALLANTINE LABORATORIES INC
AC16ZZAC
784350423
BALLANTINE LABORATORIES INC
AC16ZZAC
30D756F015CC456289
SPRAGUE ELECTRIC CO WORLD HQS
AC16ZZAC
30D756G006CB2DSM56289
SPRAGUE ELECTRIC CO WORLD HQS
AC16ZZAC
0180-191488272
MANIABARCO INC.
AC16ZZAC
30D756G016CC20P569
B. MICROFARADS, INC. DBA BARKER MICROFARADS
A325TX
500D756G016CC70P569
B. MICROFARADS, INC. DBA BARKER MICROFARADS
AC16TXAF

Characteristics

TERMINAL SURFACE TREATMENTSOLDER
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTIONDC SINGLE SECTION 16.0
CAPACITIVE ELECTRODE MATERIALALUMINUM
DC LEAKAGE AT REFERENCE TEMPMICROAMPERES 4.300
SCHEMATIC DIAGRAM DESIGNATOR
EQUIVALENT SERIES RESISTANCE AT REFERENCE TEMP IN OHMS265.00
ELECTRICAL POLARIZATIONPOLARIZED
END ITEM IDENTIFICATIONLOS ANGELES CLASS CCN(688),NIMITZ CLASS CVN,FORRESTAL CLASS CV,TICONDEROGA CLASS CG(47),KIDD CLASS DDG,STURGEON CLASS SSN(637),VIRGINIA CLASS CGN(41),SPRUANCE CLASS DD(963),SUPPORT EQUIPMENT FOR B-52 AIRCRAFT
CAPACITANCE VALUE PER SECTIONMICROFARADS SINGLE SECTION 75.000
NONDERATED OPERATING TEMPCELSIUS MINIMUM -20.0 AND CELSIUS MAXIMUM 85.0
SPECIAL FEATURESWEAPONS SYSTEM ESSENTIAL
TERMINAL TYPE AND QUANTITYUNINSULATED WIRE LEAD 2
CASE INSULATION MATERIALPLASTIC
CRITICALITY CODE JUSTIFICATIONFEAT
TOLERANCE RANGE PER SECTIONPERCENT SINGLE SECTION -10.00 TO 75.00
BODY DIAMETERINCHES NOMINAL 0.355
ANODE TYPEPLAIN FOIL
BODY STYLE
RELIABILITY INDICATORNOT ESTABLISHED
TERMINAL LENGTHINCHES MINIMUM 1.500
BODY LENGTHINCHES NOMINAL 0.874

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAAcquisition advice codePICAPICA LOASICASICA LOAAuth collabSupp collabFmr MOE rl
YA01YA01-JAN-02YA81YA
YB01YB01-APR-91YB81YB
YW01YW01-JUL-17YW81YW
ZJ01ZJ01-APR-25ZJ81ZJ
ZS01ZS01-APR-91ZS81ZS
ZU01ZU01-JUL-05ZU81ZU
ZW01ZW01-NOV-98ZW81ZW
FXGXDF3C01-JUN-06ZSXGX01SX5DGX TUFXTX
G170T10001-APR-91C174817 75
N9BNDN3C01-JUN-06ZGHGX01GH5DGXHD KE GTN9ND

Service data

Navy

COG
9B

Air Force

Fund
SF
Budget
9
MMAC
EH
PVC
N
ERRC
N

Freight

ACTY CD
TX
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
72D
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69Z0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
A
Intermediate container qty
XXX
Method of preservation
ZZ
Special requirements apply that are not represented by the code symbols; details are provided with the acquisition...
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
ZZ
Special requirement – See specific instructions or drawings provided
Wrap mat
ZZ
Special requirements – see specific instructions or drawings provided
Cush dun
ZZ
Special requirements.
THK
C
3/4 inch thick
Unit cont
ZZ
Special requirement – See specific instructions or drawings provided.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
ZZ
Special requirements
Inter cont
ZZ
Special requirement – See specific instructions or drawings provided.
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
0.1000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0040
OPI
M
All packaging data is mandatory for compliance and no substitutions are permitted.
Supplemental instructions
PRESERVATION AND PACKAGING

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Related NSNItem standardization codeOrig stdzn decDt stdzn decNIIN status code
1TX16-MAY-19820
3TX04-JUL-19820
3TX07-MAY-19820
5910-00-924-70513TX04-JUL-19820
5910-00-864-83383TX07-MAY-19820

Cancelled and replaced NIINs

FSC
5910
Cancelled NIIN
5910-01-021-6864
NIIN status code
5
Effective date
02-JUL-2026
DEMIL code
A

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.