Catalog item

CAPACITOR,FIXED,PAPER DIELECTRIC

5910FSC
00NCB code
649-0546Item number
NIIN 00-649-0546
Request a quote
Unit price
$2.99
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
00003
PINC
0000003
Criticality code
X
II
M
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
01-JAN-63
Precious metals indicator
A
ADP equipment code
0
Hazardous material indicator
P
Schedule B export code
8532250080

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DAJSMSEA0.0000$2.991U0ZQ2200X-$0.00A
01-OCT-2026DFJSMSEA0.0000$2.991U0NSF9EH-N$0.00F
01-OCT-2026DMJSMSEA0.0000$2.991U0Z15B2--1$0.00M
01-OCT-2026DNJSMSEA0.0000$2.991U09B-----$0.00N
01-OCT-2026DSJSMSEA0.0000$2.991U0N-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSCSADC
96P683935256289
SPRAGUE ELECTRIC CO WORLD HQS
AC16ZZAC
196P68393S256289
SPRAGUE ELECTRIC CO WORLD HQS
AE83HD3D
96P68353S456289
SPRAGUE ELECTRIC CO WORLD HQS
A325XX3D
2412416-3310001
NAVAIR AND NAVSEA MANAGED ORIGINAL DESIGN ACTIVITY DWG NOT MATERIAL/PARTS SUPPLIER
AE81HD3D
TWU3S68-4P5-514655
CORNELL-DUBILIER ELECTRONICS
R595XX3B

Characteristics

BODY DIAMETERINCHES NOMINAL 0.463
TERMINAL LENGTHINCHES MINIMUM 1.625
TERMINAL SURFACE TREATMENTSOLDER
BODY STYLE
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTIONDC SINGLE SECTION 300.0
TOLERANCE RANGE PER SECTIONPERCENT SINGLE SECTION -5.00 TO 5.00
SCHEMATIC DIAGRAM DESIGNATOR
CAPACITANCE VALUE PER SECTIONPICOFARADS SINGLE SECTION 68000.000
BODY LENGTHINCHES NOMINAL 0.938
NONDERATED OPERATING TEMPCELSIUS MINIMUM -55.0 AND CELSIUS MAXIMUM 125.0
TERMINAL TYPE AND QUANTITYUNINSULATED WIRE LEAD 2
RELIABILITY INDICATORNOT ESTABLISHED
INTERNAL ELECTRICAL CONNECTION TYPEINSERTED TAB
FEATURES PROVIDEDHERMETICALLY SEALED CASE
CASE INSULATION MATERIALPLASTIC
INSULATION RESISTANCE AT MAXIMUM OPERATING TEMPMEGOHM-MICROFARADS 20.0
POWER FACTOR AT REFERENCE TEMP IN PERCENT1.0000
INSULATION RESISTANCE AT REFERENCE TEMPMEGOHM-MICROFARADS 20000.0

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabSupp collabFmr MOE rl
ZF01ZF01-SEP-25ZF81ZF
ZH01ZH01-APR-91ZH81ZH
ZU01ZU01-DEC-09ZU81ZU
A918DA0001-JUN-06ZCDGX01CD5DCD GXBDA196
FXGXDF0001-JUN-06ZSXGX01SX5DGX TUFXTX
MC49DM0001-JUN-06ZPAGX01PA5DGX PAMC13
N9BNDN0001-JUN-06ZKEGX01GH5DGXGT KE HDN9ND

Service data

Army

Matcat 1
Q
Matcat 2
2
Matcat 3
2
Matcat 4 5
00
ARC
X

Navy

COG
9B

Air Force

Fund
SF
Budget
9
MMAC
EH
PVC
N
ERRC
N

Marine Corps

SAC
1
CEC
5
MEC
B2
PCC
1

Freight

ACTY CD
XX
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
72D
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
A
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
10
Physical protection
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
FA
MIL-P-130, laminated and creped wrapping paper
Cush dun
00
No requirement
THK
0
Not applicable
Unit cont
A1
Bags made of material conforming to MIL-P-130, or any bag authorized by MIL-DTL-117.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
ZZ
Special requirements
Inter cont
D1
PPP-B-566 or PPP-B-676, folding or setup box.
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
0.1000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0020
OPI
M
All packaging data is mandatory for compliance and no substitutions are permitted.
Supplemental instructions
UNIT PACKAGE MARKING REQUI

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Related NSNItem standardization codeOrig stdzn decDt stdzn decNIIN status code
5910-00-666-84593TX08-OCT-19650
5910-00-649-31613GX17-APR-20070
5910-00-648-97303TX08-OCT-19650
5910-00-539-61033TX04-NOV-19850
5910-00-630-65703TX24-AUG-19680
5910-00-957-29213GX16-APR-20070
3TX04-NOV-19850
1TX28-JAN-19800
3TX08-OCT-19650
3GX16-APR-20070
3TX24-AUG-19680
3GX17-APR-20070

Cancelled and replaced NIINs

FSCCancelled NIINNIIN status codeEffective dateDEMIL code
59105910-00-556-2075501-JUL-2026A
59105910-00-929-1298522-JUL-2026A

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.