Catalog item

CAPACITOR,FIXED,PLASTIC DIELECTR

5910FSC
00NCB code
907-8747Item number
NIIN 00-907-8747
Request a quote
Unit price
$24.46
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
00006
PINC
0000006
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
01-JAN-60
Precious metals indicator
U
Hazardous material indicator
P
Schedule B export code
8532250080

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeManagement controlNet priceUSC
01-OCT-2026DNJSMSEA0.0000$24.461U09B-----$0.00N
01-OCT-2026DSJSMSEA0.0000$24.461U0-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
2047359-153749
SOUTHERN ELECTRONICS CO INC
H595TX1D
2047359-177068
ALLIED-SIGNAL INC DBA ALLIED-SIGNAL AEROSPACE CO ELECTRODYNAMICS DIV
R595TX1B
PS143G4AT99217
BELL INDUSTRIES INC ELECTRONIC DISTRIBUTOR DIV
A525TX4D
2047359-110001
NAVAIR AND NAVSEA MANAGED ORIGINAL DESIGN ACTIVITY DWG NOT MATERIAL/PARTS SUPPLIER
A321TX1D

Characteristics

BODY STYLE
RELIABILITY INDICATORNOT ESTABLISHED
CAPACITANCE VALUE PER SECTIONMICROFARADS SINGLE SECTION 0.014
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTIONDC SINGLE SECTION 400.0
INSULATION RESISTANCE AT MAXIMUM OPERATING TEMPMEGOHMS 300000.0
BODY LENGTHINCHES NOMINAL 0.937
TERMINAL DIAMETERINCHES NOMINAL 0.025
SCHEMATIC DIAGRAM DESIGNATOR
CASE INSULATION MATERIALPLASTIC
TOLERANCE RANGE PER SECTIONPERCENT SINGLE SECTION -1.00 TO 1.00
INSULATION RESISTANCE AT REFERENCE TEMPMEGOHMS 1000000.0
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT0.0400
TERMINAL SURFACE TREATMENTSOLDER
TERMINAL LENGTHINCHES MINIMUM 1.620
NONDERATED OPERATING TEMPCELSIUS MINIMUM -20.0 AND CELSIUS MAXIMUM 71.0
TEMP COEFFICIENT OF CAPACITANCE PER SECTION IN PPM PER DEG CELSIUSSINGLE SECTION -100.0
TERMINAL TYPE AND QUANTITYUNINSULATED WIRE LEAD 2
BODY DIAMETERINCHES NOMINAL 0.416

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabSupp collabFmr MOE rl
ZA01ZA01-APR-91ZA81ZA
ZK01ZK01-OCT-25ZK81ZK
N9BNDN3L01-JUN-06ZGHGX01GH5DGXHDN9ND

Service data

Navy

COG
9B

Freight

ACTY CD
XX
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
72D
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
A
Intermediate container qty
XXX
Method of preservation
ZZ
Special requirements apply that are not represented by the code symbols; details are provided with the acquisition...
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
ZZ
Special requirement – See specific instructions or drawings provided
Wrap mat
ZZ
Special requirements – see specific instructions or drawings provided
Cush dun
ZZ
Special requirements.
THK
C
3/4 inch thick
Unit cont
ZZ
Special requirement – See specific instructions or drawings provided.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
ZZ
Special requirements
Inter cont
ZZ
Special requirement – See specific instructions or drawings provided.
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
0.0000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0000
OPI
M
All packaging data is mandatory for compliance and no substitutions are permitted.
Supplemental instructions
PRESERVATION AND PACKAGING

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
93008

Full packaging code breakdown

Related items

Standardization

Item standardization code
C
Orig stdzn dec
TX
Dt stdzn dec
06-SEP-1971
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.