Catalog item

CAPACITOR,FIXED,MICA DIELECTRIC

5910FSC
01NCB code
059-6532Item number
NIIN 01-059-6532
Request a quote
Unit price
$14.90
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
00005
PINC
0000005
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
15-APR-78
Precious metals indicator
U
Hazardous material indicator
P
Schedule B export code
8532290020

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DFJSMSEA0.0000$14.901U0NSF9EH-V$0.00F
01-OCT-2026DNJSMSEA0.0000$14.901U09B-----$0.00N
01-OCT-2026DSJSMSEA0.0000$14.901U0N-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSCSADC
0160-369128480
HEWLETT-PACKARD COMPANY DBA HP
AC11TX4DAW
0160-352028480
HEWLETT-PACKARD COMPANY DBA HP
AE81TX
DM15E750FO500WV5CR72136
ELECTRO MOTIVE CORP SUBSIDIARY OF INTERNATIONAL ELECTRONICS CORP
HC15XNAG
DM15E750F0500WV4CR72136
ELECTRO MOTIVE CORP SUBSIDIARY OF INTERNATIONAL ELECTRONICS CORP
HE83TX3B
DM15E750F72136
ELECTRO MOTIVE CORP SUBSIDIARY OF INTERNATIONAL ELECTRONICS CORP
HE85HD3D
MIL-C-5/1881349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
AE83TX
CM10ED750F0381349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
AE83TX
MIL-PRF-39001/581349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A413ZZ
CMR05E750F0DM81349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A593TX4B
MIL-C-39001/581349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A593TX4B
CMR05E750FODR81349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A223ZZ
CM05EA0750FO381349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
AC16ZZAC
034-28592739
AMPEX SYSTEMS CORP
RE849Z1D
RDM15E750FIC93790
CORNELL-DUBILIER ELECTRONICS, INC.
AE85TX
RDM15E750F1S00853
CORNELL-DUBILIER MARKETING INC
AC16TX4DAW
DM15-750F02799
ARCO ELECTRONICS INC
HC16ZZAC
034-2850PN68
AMPEX DATA SYSTEMS CORPORATION DBA AMPEX INTELLIGENT SYSTEMS
AE85ZZ
CDR15ED750FO314655
CORNELL-DUBILIER ELECTRONICS
RC15XNAG

Characteristics

BODY STYLE
RELIABILITY INDICATORESTABLISHED
RELIABILITY FAILURE RATE LEVEL IN PERCENT0.0100
TERMINAL LENGTHINCHES MINIMUM 1.000
BODY LENGTHINCHES MINIMUM 0.400 AND INCHES MAXIMUM 0.450
BODY WIDTHINCHES MAXIMUM 0.360
BODY HEIGHTINCHES MINIMUM 0.095 AND INCHES MAXIMUM 0.180
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES NOMINAL 0.225
TERMINAL DIAMETERINCHES NOMINAL 0.025
SCHEMATIC DIAGRAM DESIGNATOR
INSULATION RESISTANCE AT MAXIMUM OPERATING TEMPMEGOHMS 10000.0
CAPACITANCE VALUE PER SECTIONPICOFARADS SINGLE SECTION 75.000
NONDERATED OPERATING TEMPCELSIUS MINIMUM -55.0 AND CELSIUS MAXIMUM 125.0
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTIONDC SINGLE SECTION 500.0
TEMP COEFFICIENT OF CAPACITANCE RANGE PER SECTION IN PPM PER DEG CELSIUSSINGLE SECTION -20.0 TO 100.0
TOLERANCE RANGE PER SECTIONPERCENT SINGLE SECTION -1.00 TO 1.00
INSULATION RESISTANCE AT REFERENCE TEMPMEGOHMS 100000.0
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT0.0002
TERMINAL SURFACE TREATMENTSOLDER
MATERIALCASE PLASTIC
TEST DATA DOCUMENTSPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 81349--IL-C-39001
TERMINAL TYPE AND QUANTITYUNINSULATED WIRE LEAD 2
SPECIFICATION/STANDARD DATAGOVERNMENT SPECIFICATION 81349--IL-C-39001 TO 5

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabSupp collabFmr MOE rl
WG01WG01-OCT-17WG81WG
WP01WP01-NOV-03WP81WP
YB01YB01-APR-91YB81YB
ZC01ZC01-APR-91ZC81ZC
ZH01ZH01-APR-91ZH81ZH
ZJ01ZJ01-APR-25ZJ81ZJ
ZU01ZU01-JUL-05ZU81ZU
ZW01ZW01-NOV-98ZW81ZW
FXGXDF1T01-JUN-06ZSXGX01SX5DGX TUFXTX
N9BNDN1T01-JUN-06ZKEGX01GH5DGXHD GT HX JB KEN9ND
S911DG1T01-JUN-06ZXNGX01XN5DXN GXS007

Service data

Navy

COG
9B

Air Force

Fund
SF
Budget
9
MMAC
EH
PVC
V
ERRC
N

Freight

ACTY CD
TX
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
72D
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
A
Intermediate container qty
XXX
Method of preservation
ZZ
Special requirements apply that are not represented by the code symbols; details are provided with the acquisition...
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
ZZ
Special requirement – See specific instructions or drawings provided
Wrap mat
ZZ
Special requirements – see specific instructions or drawings provided
Cush dun
ZZ
Special requirements.
THK
C
3/4 inch thick
Unit cont
ZZ
Special requirement – See specific instructions or drawings provided.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
ZZ
Special requirements
Inter cont
ZZ
Special requirement – See specific instructions or drawings provided.
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
0.1000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0070
OPI
M
All packaging data is mandatory for compliance and no substitutions are permitted.
Supplemental instructions
PRESERVATION AND PACKAGING

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
89108

Full packaging code breakdown

Related items

Standardization

Related NSNItem standardization codeOrig stdzn decDt stdzn decNIIN status code
5910-00-061-24073TX24-AUG-19850
5910-00-123-5727ETX05-DEC-19770
BTX09-AUG-19910
3TX24-AUG-19850
ETX05-DEC-19770

Cancelled and replaced NIINs

FSCCancelled NIINNIIN status codeEffective dateDEMIL code
59105910-01-067-7700502-JUL-2026A
59105910-00-724-6083522-JUL-2026A

Request a quote