Catalog item
Request a quoteCAPACITOR,FIXED,ELECTROLYTIC
5910FSC
01NCB code
097-8949Item number
NIIN 01-097-8949
- Unit price
- $56.86
- Unit of issue
- EA
- Source of supply
- SMS
- DEMIL code
- A
Identification
- Item name code
- 00008
- PINC
- 0000008
- Criticality code
- X
- II
- 0
- DEMIL code
- A
- DEMIL integrity code
- 1
- NIIN assigned
- 22-JUL-80
- Precious metals indicator
- U
- Hazardous material indicator
- P
- Schedule B export code
- 8532290040
Management
| Effective date | Major organizational entity | Acquisition advice code | Source of supply | Unit of issue | Unit of measure quantity | Unit price | Quantity per unit pack | Controlled inventory item code | Shelf-life code | Management control | Net price | USC |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 01-OCT-2026 | DN | Z | SMS | EA | 0.0000 | $56.86 | 1 | U | 0 | 9B----- | $0.00 | N |
| 01-OCT-2026 | DS | Z | SMS | EA | 0.0000 | $56.86 | 1 | U | 0 | ------- | $0.00 | I |
Part numbers
| Part number | CAGE | CAGE status | RNCC | RNVC | Document availability code | RNAAC | RNFC | RNSC |
|---|---|---|---|---|---|---|---|---|
| 138D146X0150T2 | 56289 SPRAGUE ELECTRIC CO WORLD HQS | A | 5 | 9 | 4 | 9Z | 4 | B |
| 137D146X0125F2 | 56289 SPRAGUE ELECTRIC CO WORLD HQS | A | E | 8 | 3 | TX | 3 | D |
| MIL-PRF-39006/22 | 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M | A | 4 | 1 | E | ZZ | ||
| M39006/22-0210 | 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M | A | 2 | 2 | E | ZZ | ||
| V22-9-5275-138D226X0150T2 | D3683 VINCORION ADVANCED SYSTEMS GMBH DIV JENOPTIK DEFENSE AND CIVIL SYSTEMS | A | 5 | 2 | 3 | ZG | 4 | A |
| V22-9-5275-138D146X0150T2 | D3683 VINCORION ADVANCED SYSTEMS GMBH DIV JENOPTIK DEFENSE AND CIVIL SYSTEMS | A | 5 | 2 | 3 | ZG | 4 | A |
Characteristics
| BODY STYLE | |
|---|---|
| RELIABILITY INDICATOR | ESTABLISHED |
| RELIABILITY FAILURE RATE LEVEL IN PERCENT | 1.000 |
| TERMINAL LENGTH | INCHES NOMINAL 2.250 |
| BODY DIAMETER | INCHES NOMINAL 0.312 |
| BODY LENGTH | INCHES NOMINAL 2.250 |
| TERMINAL DIAMETER | INCHES NOMINAL 0.025 |
| SCHEMATIC DIAGRAM DESIGNATOR | |
| ELECTRICAL POLARIZATION | POLARIZED |
| FEATURES PROVIDED | HERMETICALLY SEALED CASE |
| CAPACITANCE VALUE PER SECTION | MICROFARADS SINGLE SECTION 14.000 |
| NONDERATED OPERATING TEMP | CELSIUS MINIMUM -55.0 AND CELSIUS MAXIMUM 85.0 |
| NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION | DC SINGLE SECTION 125.0 |
| TOLERANCE RANGE PER SECTION | PERCENT SINGLE SECTION -20.00 TO 20.00 |
| CAPACITIVE ELECTRODE MATERIAL | TANTALUM |
| EQUIVALENT SERIES RESISTANCE AT REFERENCE TEMP IN OHMS | 4.00 |
| DC LEAKAGE AT REFERENCE TEMP | MICROAMPERES 4.000 |
| CASE INSULATION MATERIAL | PLASTIC |
| TERMINAL TYPE AND QUANTITY | UNINSULATED WIRE LEAD 2 |
| SPECIFICATION/STANDARD DATA | GOVERNMENT SPECIFICATION 81349--IL-RF-39006 TO 22 |
MOE rules
| MOE rule | MOE CD | AMC | AMSC | Date assigned | IMC | IMCA | PICA | PICA LOA | SICA | SICA LOA | Auth collab | Supp collab | Fmr MOE rl |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ZA01 | ZA | 01-FEB-26 | ZA | 81 | ZA | ||||||||
| ZG01 | ZG | 01-APR-91 | ZG | 81 | ZG | ||||||||
| ZH01 | ZH | 01-SEP-09 | ZH | 81 | ZH | ||||||||
| ZR01 | ZR | 01-APR-91 | ZR | 81 | ZR | ||||||||
| N9BN | DN | 1 | T | 01-JUN-06 | Z | GH | GX | 01 | GH | 5D | GX | GT KE | N9ND |
Service data
Navy
- COG
- 9B
Freight
- ACTY CD
- ZG
- NMFC
- 061700
- NMFC sub
- Z
- Uniform freight class
- 34580
- Less than truckload
- W
- Water commodity code
- 72D
- Type of cargo code
- Z
- Special handling code
- 9
- Air dimension code
- A
- Air commodity code
- HZ
- NMF description
- ELEC APPLIANCES/INSTRUMENTS NOI
Packaging
Unit and preservation
- PICA SICA
- P
- PKG cat
- 69F0
- Unpackaged weight
- 0.0000
- Unpackaged width
- 0.000
- Unpackaged length
- 0.000
- Unpackaged height
- 0.000
- TOS
- A
- Intermediate container qty
- XXX
- Method of preservation
- ZZSpecial requirements apply that are not represented by the code symbols; details are provided with the acquisition...
- Clng drying
- 1Any suitable process that is not injurious to the item.
- Pres mat
- ZZSpecial requirement – See specific instructions or drawings provided
- Wrap mat
- ZZSpecial requirements – see specific instructions or drawings provided
- Cush dun
- ZZSpecial requirements.
- THK
- C3/4 inch thick
- Unit cont
- ZZSpecial requirement – See specific instructions or drawings provided.
- PKG data source
- P
Unit pack
- PICA SICA
- P
- SPC MKG
- ZZSpecial requirements
- Inter cont
- ZZSpecial requirement – See specific instructions or drawings provided.
- Lvl A
- QPacking shall be accomplished in accordance with table C.II for the packing level specified.
- Lvl b
- QPacking shall be accomplished in accordance with table C-II for the packing level specified.
- Unit pack weight
- 0.1000
- UP SZ MAXB
- 0.00000
- UP SZ MAXL
- 0.00000
- UP SZ MAXH
- 0.00000
- Unit pack cube
- 0.0040
- OPI
- MAll packaging data is mandatory for compliance and no substitutions are permitted.
- Supplemental instructions
- UNIT PACKAGE MARKING REQUI
Packaging instructions
- PICA SICA
- P
- PKG design ACTY
- 14933
- SPI date
- 81176
Related items
Standardization
- Item standardization code
- 5
- Orig stdzn dec
- 96
- Dt stdzn dec
- 08-FEB-2008
- NIIN status code
- 0
Cancelled and replaced NIINs
- FSC
- 5910
- Cancelled NIIN
- 5910-00-855-3524
- NIIN status code
- 5
- Effective date
- 02-JUL-2026
- DEMIL code
- A
Request a quote