Catalog item

CAPACITOR,FIXED,ELECTROLYTIC

5910FSC
01NCB code
119-4336Item number
NIIN 01-119-4336
Request a quote
Unit price
$70.78
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
00008
PINC
0000008
Criticality code
H
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
24-SEP-81
Precious metals indicator
A
Hazardous material indicator
P
Schedule B export code
8532290040

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DAZSMSEA0.0000$70.781U0ZQ2200X-$0.00A
01-OCT-2026DFZSMSEA0.0000$70.781U0NSF9EH-N$0.00F
01-OCT-2026DMDSMSEA0.0000$70.781U0Z15B2B--$0.00M
01-OCT-2026DNZSMSEA0.0000$70.781U09B----9$0.00N
01-OCT-2026DSZSMSEA0.0000$70.781U0N-------$0.00I
01-OCT-2026GPZSMSEA0.0000$70.781U0-------$0.00C

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSCSADC
0160-023428480
HEWLETT-PACKARD COMPANY DBA HP
AC16ZZAC
339367-32556232
LOCKHEED MARTIN CORPORATION DIV RMS - MITCHEL FIELD
AC16ZZAC
M39006/22-017181349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
AC16ZZAC
M39006/22-061081349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A594ZZ4B
M39006/22-039181349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A593TXB
M39006/09-636481349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
AC16ZZAC
MIL-PRF-39006/2281349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A413ZZ
M39006/22-636481349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
AC1EZZAC
M39006-09-436381349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
AE84ZZ3D
M39006/09-856881349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A593ZZ
MILC39006-981349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A593TXB
M39006-09-415981349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
AC16ZZAC
M39006-09-877481349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A593TXB
M39006-22-017081349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
AC16ZZAC
MIL-C-39006/981349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A593TXB
M39006-09-415881349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A593TXB
M39006/22-656881349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
AC16ZZAC
M39006/22-061181349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A223TX4D
MIL-C-39006/2281349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A593TX4B
M39006/09-856981349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A593TXB
M39006/09-8364M81349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
AC16ZZAC

Characteristics

BODY STYLE
MIL-STD-1276 WIRE LEAD TYPE DESIGNATORN-4
RELIABILITY INDICATORESTABLISHED
RELIABILITY FAILURE RATE LEVEL IN PERCENT0.0100
TERMINAL LENGTHINCHES NOMINAL 2.500
BODY DIAMETERINCHES MAXIMUM 0.312
BODY LENGTHINCHES NOMINAL 0.719
TERMINAL DIAMETERINCHES NOMINAL 0.025
SCHEMATIC DIAGRAM DESIGNATOR
ANODE TYPESOLID
IMPEDANCE AT MINIMUM OPERATING TEMP IN OHMS90.0
ELECTRICAL POLARIZATIONPOLARIZED
CAPACITANCE VALUE PER SECTIONMICROFARADS SINGLE SECTION 33.000
NONDERATED OPERATING TEMPCELSIUS MINIMUM -55.0 AND CELSIUS MAXIMUM 85.0
DC LEAKAGE AT MAXIMUM OPERATING TEMPMICROAMPERES 10.0
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTIONDC SINGLE SECTION 75.0
TOLERANCE RANGE PER SECTIONPERCENT SINGLE SECTION -10.00 TO 10.00
CAPACITIVE ELECTRODE MATERIALTANTALUM
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT10.0000
DC LEAKAGE AT REFERENCE TEMPMICROAMPERES 1.000
CASE INSULATION MATERIALPLASTIC
NUCLEAR HARDNESS CRITICAL FEATUREHARDENED
TEST DATA DOCUMENTSPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 81349--IL-C-39006
TERMINAL TYPE AND QUANTITYUNINSULATED WIRE LEAD 2
SPECIFICATION/STANDARD DATAGOVERNMENT SPECIFICATION 81349--IL-C-39006 TO 22

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAAcquisition advice codePICAPICA LOASICASICA LOAAuth collabSupp collabFmr MOE rl
WB01WB01-FEB-05WB81WB
WP01WP01-JAN-04WP81WP
WI01WI01-JUN-01WI81WI
YA01YA01-OCT-00YA81YA
YB01YB01-APR-91YB81YB
YJ01YJ01-OCT-06YJ81YJ
YD01YD01-NOV-16YD81YD
YW01YW01-JUL-17YW81YW
ZA01ZA01-APR-91ZA81ZA
ZC01ZC01-APR-91ZC81ZC
ZE01ZE01-APR-91ZE81ZE
ZF01ZF01-APR-96ZF81ZF
ZG01ZG01-APR-91ZG81ZG
ZH01ZH01-APR-91ZH81ZH
ZJ01ZJ01-APR-25ZJ81ZJ
ZP01ZP01-APR-91ZP81ZP
ZR01ZR01-JUL-97ZR81ZR
ZU01ZU01-OCT-06ZU81ZU
ZS01ZS01-APR-91ZS81ZS
ZT01ZT01-APR-91ZT81ZT
ZW01ZW01-NOV-98ZW81ZW
ZX01ZX01-APR-91ZX81
A918DA1T01-AUG-06ZCDGX01CD5DCD GXCL CT AZ BDA196
C911GP1T01-AUG-06GX01XG5DXG GXXHC007
BGX1GE1T01-APR-07GX01485DGX 48
FXGXDF1T01-AUG-06ZSXGX01SX5DGX TUFXTX
G860T10001-FEB-96C864875 86
MC49DM1T01-AUG-06ZPAGX01PA5DGX PAMC13
N9BNDN1T01-AUG-06ZGHGX01GH5DGXGT HS KE HD JB JVN9ND
S911DG1T01-AUG-06ZXNGX01XN5DXN GXS007
VJ01VJ01-MAR-19VJ81VJ

Service data

Army

Matcat 1
Q
Matcat 2
2
Matcat 3
2
Matcat 4 5
00
ARC
X

Navy

COG
9B
SMCC
9

Air Force

Fund
SF
Budget
9
MMAC
EH
PVC
N
ERRC
N

Marine Corps

SAC
1
CEC
5
MEC
B2
MIC
B

Freight

ACTY CD
TX
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
72D
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
ZZ
Special requirements apply that are not represented by the code symbols; details are provided with the acquisition...
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
ZZ
Special requirement – See specific instructions or drawings provided
Wrap mat
ZZ
Special requirements – see specific instructions or drawings provided
Cush dun
ZZ
Special requirements.
THK
C
3/4 inch thick
Unit cont
ZZ
Special requirement – See specific instructions or drawings provided.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
ZZ
Special requirements
Inter cont
ZZ
Special requirement – See specific instructions or drawings provided.
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
0.1000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0070
OPI
M
All packaging data is mandatory for compliance and no substitutions are permitted.
Supplemental instructions
UNIT PACKAGE MARKING REQUI

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Related NSNItem standardization codeOrig stdzn decDt stdzn decNIIN status code
5910-01-004-3274ETX17-FEB-19780
5910-00-430-59533TX04-JUN-19720
5910-00-851-33163TX04-JUN-19720
5910-01-086-2770ETX17-SEP-19820
5910-00-110-9198ETX04-AUG-19720
5910-00-470-9159ETX04-AUG-19720
5910-01-073-7020ETX17-SEP-19820
5910-00-903-29813TX04-JUN-19720
5910-00-057-56833TX04-JAN-19830
5910-01-023-5372ETX27-AUG-19820
5910-01-070-9482ETX25-APR-19800
5910-01-111-5203ETX17-SEP-19820
5910-00-733-37673TX04-JUN-19720
5910-00-993-40293TX04-JUN-19720
5910-01-016-4067ETX17-FEB-19780
5910-00-558-9149ETX04-OCT-19770
5910-00-466-3406ETX04-AUG-19720
5910-00-838-35893TX04-JUN-19720
5910-00-476-8256ETX04-AUG-19720
5910-00-804-64123TX04-JUN-19720
5910-01-267-3629ETX23-JUL-19920
5910-00-082-47073TX04-JUN-19720
5910-00-466-33993TX03-NOV-19730
5910-00-878-98273TX04-JUN-19720
5910-00-613-4506ETX17-FEB-19780
5910-01-419-4341ETX20-APR-19960
ETX23-JUL-19920
ETX17-SEP-19820
3TX03-NOV-19730
ETX27-AUG-19820
ETX17-FEB-19780
3TX04-JUN-19720
ETX04-AUG-19720
ETX04-OCT-19770
3TX04-JAN-19830
ETX25-APR-19800
BTX23-JUL-19920
ETX20-APR-19960

Cancelled and replaced NIINs

FSCCancelled NIINNIIN status codeEffective dateDEMIL code
59105910-00-497-7956522-JUL-2026A
59105910-01-093-4360522-JUL-2026A
59105910-01-367-2738522-JUL-2026A
59105910-00-761-4415502-JUL-2026A

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.