Catalog item
Request a quoteCAPACITOR,FIXED,CERAMIC DIELECTR
5910FSC
01NCB code
182-6481Item number
NIIN 01-182-6481
- Unit price
- $3.05
- Unit of issue
- EA
- Source of supply
- SMS
- DEMIL code
- A
Identification
- Item name code
- 00007
- PINC
- 0000007
- Criticality code
- X
- II
- 0
- DEMIL code
- A
- DEMIL integrity code
- 1
- NIIN assigned
- 26-JUN-84
- Precious metals indicator
- A
- Hazardous material indicator
- P
- Schedule B export code
- 8532290040
Management
| Effective date | Major organizational entity | Acquisition advice code | Source of supply | Unit of issue | Unit of measure quantity | Unit price | Quantity per unit pack | Controlled inventory item code | Shelf-life code | Recoverability code | Management control | Net price | USC |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 01-OCT-2026 | DF | Z | SMS | EA | 0.0000 | $3.05 | 1 | U | 0 | N | SF9EH-N | $0.00 | F |
| 01-OCT-2026 | DN | Z | SMS | EA | 0.0000 | $3.05 | 1 | U | 0 | 9B----- | $0.00 | N | |
| 01-OCT-2026 | DS | Z | SMS | EA | 0.0000 | $3.05 | 1 | U | 0 | N | ------- | $0.00 | I |
Part numbers
| Part number | CAGE | CAGE status | RNCC | RNVC | Document availability code | RNAAC | RNSC | SADC |
|---|---|---|---|---|---|---|---|---|
| 258330-2197 | 37695 RAYTHEON COMPANY | A | 7 | 2 | 2 | 9Z | D | |
| 150100C0G150J | 51642 CENTRE CAPACITOR INC | A | C | 1 | 1 | ZZ | AC | |
| 150-100-NP0-150G | 51642 CENTRE CAPACITOR INC | A | 5 | 2 | 4 | 9Z | D | |
| 8111-100-C0G-150G | 59660 TUSONIX, LLC | A | 5 | 9 | E | TX | ||
| 8101-100COG0150K | 59660 TUSONIX, LLC | A | E | 8 | 5 | TX | ||
| 8111-100-C0G-150G | 72982 ERIE SPECIALTY PRODUCTS INC | A | 5 | 9 | E | TX | B | |
| 8101-100C0G0150K | 72982 ERIE SPECIALTY PRODUCTS INC | A | 5 | 9 | E | TX | B | |
| 150-100-NP0-560J | 02799 ARCO ELECTRONICS INC | H | C | 1 | 6 | ZZ | AC | |
| SR151A150GAA | 04222 KYOCERA AVX COMPONENTS CORPORATION | A | 5 | 2 | E | TX | ||
| 3418-100-A-150G | 04222 KYOCERA AVX COMPONENTS CORPORATION | A | 5 | 9 | E | TX | B | |
| 150-100-NPO-560J | 07299 ATK TACTICAL SYSTEMS COMPANY LLC DIV ATK TACTICAL SYSTEMS COMPANY, ELKTON OPERATIONS | A | C | 1 | 6 | ZZ | AC | |
| 8101-100C0G0150K | 18796 MURATA ERIE NORTH AMERICA INC STATE COLLEGE OPNS | H | 5 | 9 | E | TX | B | |
| RPE110C0G150G100V | 18796 MURATA ERIE NORTH AMERICA INC STATE COLLEGE OPNS | H | 5 | 9 | E | TX | B | |
| 720-010-150 | 17903 ANDREW SCICOMM INC | H | C | 1 | 6 | ZZ | AC | |
| CN15A150G | 16546 MEPCO/CENTRALAB A NORTH AMERICAN PHILIPS CO | H | 3 | 9 | 4 | 9Z | D |
Characteristics
| BODY STYLE | |
|---|---|
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| TERMINAL LENGTH | INCHES MINIMUM 1.250 |
| BODY LENGTH | INCHES MAXIMUM 0.150 |
| BODY WIDTH | INCHES MAXIMUM 0.150 |
| BODY HEIGHT | INCHES MAXIMUM 0.100 |
| CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | INCHES NOMINAL 0.100 |
| TERMINAL DIAMETER | INCHES NOMINAL 0.016 |
| SCHEMATIC DIAGRAM DESIGNATOR | |
| CAPACITANCE VALUE PER SECTION | PICOFARADS SINGLE SECTION 15.000 |
| NONDERATED OPERATING TEMP | CELSIUS MINIMUM -55.0 AND CELSIUS MAXIMUM 125.0 |
| NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION | DC SINGLE SECTION 100.0 |
| TOLERANCE OF TEMP COEFFICIENT PER SECTION IN PPM PER DEG CELSIUS | SINGLE SECTION -30.0 TO 30.0 |
| TOLERANCE RANGE PER SECTION | PERCENT SINGLE SECTION -2.00 TO 2.00 |
| MATERIAL | CASE PLASTIC |
| TERMINAL TYPE AND QUANTITY | UNINSULATED WIRE LEAD 2 |
MOE rules
| MOE rule | MOE CD | AMC | AMSC | Date assigned | IMC | IMCA | PICA | PICA LOA | SICA | SICA LOA | Auth collab | Supp collab | Fmr MOE rl |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| YA01 | YA | 01-JAN-17 | YA | 81 | YA | ||||||||
| YB01 | YB | 01-FEB-94 | YB | 81 | YB | ||||||||
| YJ01 | YJ | 01-APR-91 | YJ | 81 | YJ | ||||||||
| ZH01 | ZH | 01-APR-91 | ZH | 81 | ZH | ||||||||
| ZU01 | ZU | 01-MAY-08 | ZU | 81 | ZU | ||||||||
| FXGX | DF | 1 | R | 01-NOV-05 | Z | SX | GX | 01 | SX | 5D | GX TU | FXTX | |
| N9BN | DN | 1 | R | 01-NOV-05 | Z | KE | GX | 01 | GH | 5D | GX | HD KE | N9ND |
| S911 | DG | 1 | R | 01-NOV-05 | Z | XN | GX | 01 | XN | 5D | XN GX | S007 |
Service data
Navy
- COG
- 9B
Air Force
- Fund
- SF
- Budget
- 9
- MMAC
- EH
- PVC
- N
- ERRC
- N
Freight
- ACTY CD
- ZK
- NMFC
- 061700
- NMFC sub
- Z
- Uniform freight class
- 34580
- Less than truckload
- W
- Water commodity code
- 72D
- Type of cargo code
- Z
- Special handling code
- 9
- Air dimension code
- A
- Air commodity code
- HZ
- NMF description
- ELEC APPLIANCES/INSTRUMENTS NOI
Packaging
Unit and preservation
- PICA SICA
- P
- PKG cat
- 69F0
- Unpackaged weight
- 0.0000
- Unpackaged width
- 0.000
- Unpackaged length
- 0.000
- Unpackaged height
- 0.000
- TOS
- A
- Intermediate container qty
- XXX
- Method of preservation
- ZZSpecial requirements apply that are not represented by the code symbols; details are provided with the acquisition...
- Clng drying
- 1Any suitable process that is not injurious to the item.
- Pres mat
- ZZSpecial requirement – See specific instructions or drawings provided
- Wrap mat
- ZZSpecial requirements – see specific instructions or drawings provided
- Cush dun
- ZZSpecial requirements.
- THK
- C3/4 inch thick
- Unit cont
- ZZSpecial requirement – See specific instructions or drawings provided.
- PKG data source
- P
Unit pack
- PICA SICA
- P
- SPC MKG
- ZZSpecial requirements
- Inter cont
- ZZSpecial requirement – See specific instructions or drawings provided.
- Lvl A
- QPacking shall be accomplished in accordance with table C.II for the packing level specified.
- Lvl b
- QPacking shall be accomplished in accordance with table C-II for the packing level specified.
- Unit pack weight
- 0.1000
- UP SZ MAXB
- 0.00000
- UP SZ MAXL
- 0.00000
- UP SZ MAXH
- 0.00000
- Unit pack cube
- 0.0090
- OPI
- MAll packaging data is mandatory for compliance and no substitutions are permitted.
- Supplemental instructions
- UNIT PACKAGE MARKING REQUI
Packaging instructions
- PICA SICA
- P
- PKG design ACTY
- 14933
- SPI date
- 00000
Related items
Standardization
- Item standardization code
- 5
- Orig stdzn dec
- TX
- Dt stdzn dec
- 01-JUN-2001
- NIIN status code
- 0
Cancelled and replaced NIINs
| FSC | Cancelled NIIN | NIIN status code | Effective date | DEMIL code |
|---|---|---|---|---|
| 5910 | 5910-01-194-9200 | 5 | 02-JUL-2026 | A |
| 5910 | 5910-01-191-9819 | 5 | 02-JUL-2026 | A |
Request a quote
Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.