Catalog item

CAPACITOR,FIXED,GLASS DIELECTRIC

5910FSC
01NCB code
193-8345Item number
NIIN 01-193-8345
Request a quote
Unit price
$72.92
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
00004
PINC
0000004
Criticality code
X
II
0
DEMIL code
A
NIIN assigned
08-NOV-84
Precious metals indicator
A
Hazardous material indicator
P
Schedule B export code
8532290040
FedMall
Y

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DAXSMSEA0.0000$72.921U0ZQ2200X-$0.00A
01-OCT-2026DSXSMSEA0.0000$72.921U0N-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAAC
M23269/09-401581349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A22ETX
MIL-C-23269/981349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A41ETX

Characteristics

BODY STYLE
RELIABILITY INDICATORESTABLISHED
RELIABILITY FAILURE RATE LEVEL IN PERCENT0.1000
TERMINAL LENGTHINCHES MINIMUM 1.125
BODY LENGTHINCHES MAXIMUM 0.315
BODY WIDTHINCHES MAXIMUM 0.315
BODY HEIGHTINCHES MAXIMUM 0.100
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES NOMINAL 0.200
TERMINAL DIAMETERINCHES MINIMUM 0.024 AND INCHES MAXIMUM 0.029
SCHEMATIC DIAGRAM DESIGNATOR
END ITEM IDENTIFICATION5820-01-099-7798 RADIO SET
FEATURES PROVIDEDHERMETICALLY SEALED CASE
INSULATION RESISTANCE AT MAXIMUM OPERATING TEMPMEGOHMS 100000.0
CAPACITANCE VALUE PER SECTIONPICOFARADS SINGLE SECTION 12.000
NONDERATED OPERATING TEMPCELSIUS MINIMUM -55.0 AND CELSIUS MAXIMUM 125.0
TEMP COEFFICIENT OF CAPACITANCE PER SECTION IN PPM PER DEG CELSIUSSINGLE SECTION 0.0
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTIONDC SINGLE SECTION 100.0
TOLERANCE OF TEMP COEFFICIENT PER SECTION IN PPM PER DEG CELSIUSSINGLE SECTION -25.0 TO 25.0
TOLERANCE RANGE PER SECTIONPERCENT SINGLE SECTION -5.00 TO 5.00
INSULATION RESISTANCE AT REFERENCE TEMPMEGOHMS 500000.0
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT0.3000
TERMINAL SURFACE TREATMENTSOLDER
MATERIALCASE GLASS
TEST DATA DOCUMENTSPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 81349--IL-C-23269
TERMINAL TYPE AND QUANTITYUNINSULATED WIRE LEAD 2
SPECIFICATION/STANDARD DATAGOVERNMENT SPECIFICATION 81349--IL-C-23269 TO 9

MOE rules

MOE rule
A918
MOE CD
DA
AMC
1
AMSC
G
Date assigned
01-JUN-06
IMC
Z
IMCA
CD
PICA
GX
PICA LOA
01
SICA
CD
SICA LOA
5D
Auth collab
CD GX
Supp collab
CL
Fmr MOE rl
A196

Service data

Army

Matcat 1
Q
Matcat 2
2
Matcat 3
2
Matcat 4 5
00
ARC
X

Freight

ACTY CD
TH
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
72D
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
A
Intermediate container qty
XXX
Method of preservation
ZZ
Special requirements apply that are not represented by the code symbols; details are provided with the acquisition...
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
ZZ
Special requirement – See specific instructions or drawings provided
Wrap mat
ZZ
Special requirements – see specific instructions or drawings provided
Cush dun
ZZ
Special requirements.
THK
C
3/4 inch thick
Unit cont
ZZ
Special requirement – See specific instructions or drawings provided.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
ZZ
Special requirements
Inter cont
ZZ
Special requirement – See specific instructions or drawings provided.
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
0.0000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0000
OPI
M
All packaging data is mandatory for compliance and no substitutions are permitted.
Supplemental instructions
UNIT PACKAGE MARKING REQUI

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
2
Orig stdzn dec
TX
Dt stdzn dec
18-JAN-1986
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.