Catalog item

CAPACITOR,FIXED,PLASTIC DIELECTR

5910FSC
01NCB code
207-8903Item number
NIIN 01-207-8903
Request a quote
Unit price
$3,698.47
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
00006
PINC
0000006
Criticality code
X
II
0
DEMIL code
A
NIIN assigned
07-MAY-85
Precious metals indicator
A
Hazardous material indicator
P
Schedule B export code
8532250080

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DAJSMSEA0.0000$3,698.471U0ZQ2200X-$0.00A
01-OCT-2026DSJSMSEA0.0000$3,698.471U0N-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAAC
3M201-406A58364
BYCAP INC
A52AZZ
160-1287-301378
SPELLMAN HIGH-VOLTAGE ELECTRONICS CORPORATION DBA SPELLMAN HIGH-VOLTAGE ELECTRONICS CORP
A516BD
160-1287-313619
EMS DEVELOPMENT CORPORATION DBA EMS DEVELOPMENT CORP
A52AZZ
11440554-318876
US ARMY AVIATION AND MISSILE COMMAND
A321BD

Characteristics

BODY STYLE
RELIABILITY INDICATORNOT ESTABLISHED
TERMINAL LENGTHINCHES MINIMUM 0.600 AND INCHES MAXIMUM 0.680
BODY LENGTHINCHES MAXIMUM 2.800
BODY WIDTHINCHES MAXIMUM 2.780
BODY HEIGHTINCHES MAXIMUM 1.810
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTHINCHES NOMINAL 1.310
TERMINAL DIAMETERINCHES NOMINAL 0.190
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTHINCHES MINIMUM 2.190 AND INCHES MAXIMUM 2.210
SCHEMATIC DIAGRAM DESIGNATOR
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTHINCHES MINIMUM 2.190 AND INCHES MAXIMUM 2.210
INTERNAL ELECTRICAL CONNECTION TYPEEXTENDED FOIL
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
MOUNTING FACILITY TYPE AND QUANTITYTHREADED MOUNTING STUDS 4
SECTION QUANTITY2
FEATURES PROVIDEDHERMETICALLY SEALED CASE
CAPACITANCE VALUE PER SECTIONMICROFARADS ALL SECTIONS 20.000
NONDERATED OPERATING TEMPCELSIUS MINIMUM -45.6 AND CELSIUS MAXIMUM 71.0
NOMINAL THREAD SIZEINCHES 0.164
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTIONDC ALL SECTIONS 200.0
TOLERANCE RANGE PER SECTIONPERCENT ALL SECTIONS -10.00 TO 10.00
INSULATION RESISTANCE AT REFERENCE TEMPMEGOHM-MICROFARADS 25000.0
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT0.500
DIELECTRIC MATERIALPLASTIC
CASE INSULATION MATERIALPLASTIC
TERMINAL TYPE AND QUANTITYTHREADED STUD 4

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabSupp collabFmr MOE rl
YD01YD01-APR-17YD81YD
ZJ01ZJ01-APR-25ZJ81ZJ
ZX01ZX01-NOV-05ZX81
A918DA3H01-JUN-06ZBDGX01CD5DCD GXBDA196

Service data

Army

Matcat 1
Q
Matcat 2
2
Matcat 3
2
Matcat 4 5
00
ARC
X

Freight

ACTY CD
BD
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
72D
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69FZ
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
A
Intermediate container qty
XXX
Method of preservation
ZZ
Special requirements apply that are not represented by the code symbols; details are provided with the acquisition...
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
ZZ
Special requirement – See specific instructions or drawings provided
Wrap mat
ZZ
Special requirements – see specific instructions or drawings provided
Cush dun
ZZ
Special requirements.
THK
C
3/4 inch thick
Unit cont
ZZ
Special requirement – See specific instructions or drawings provided.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
ZZ
Special requirements
Inter cont
ZZ
Special requirement – See specific instructions or drawings provided.
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
1.0000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0810
OPI
M
All packaging data is mandatory for compliance and no substitutions are permitted.
Supplemental instructions
UNIT PACKAGE MARKING REQUI

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
95325

Full packaging code breakdown

Related items

Standardization

Item standardization code
C
Orig stdzn dec
TX
Dt stdzn dec
04-APR-1992
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.